PENTAIR PSE1800-PUV7-P Whole House Installation Kit Instruction Manual
- June 10, 2024
- Pentair
Table of Contents
PENTAIR PSE1800-PUV7-P Whole House Installation Kit
PARTS OF THE SYSTEM
-
One (1) Roll of Plumber’s Tape
-
One (1) John Guest 1” Male NPT Connector
-
Three (3) John Guest 1” NPT to Stem
-
One (1) John Guest to Clack 1” Stainless Flex Pipe
-
One (1) Clack to Clack 1” Stainless Flex Pipe
-
One (1)Clack to Female Threaded 1” Stainless Flex Pipe
-
One (1) Female Threaded to John Guest 1” Stainless Flex Pipe
INSTALLATION
Note: Before starting this step, be sure to have your prefilter housing
mounted following the instructions that came with the system
you purchased.
- Wrap (A) plumber’s tape two (2) to three (3) times around the threaded end of the (B) John Guest 1” Male NPT Connector.
- Thread fitting into inlet side of prefilter housing. Hand tighten and follow with one (1) to two (2) turns using a wrench.
- Wrap (A) plumber’s tape two (2) to three (3) times around the threaded end of one (1) of the (C) John Guest 1” NPT to Stem.
- Thread fitting into the outlet side of prefilter housing. Hand tighten and follow with one (1) to two (2) turns using a wrench.
- Bring main cold water line from street and plug into John Guest connection on inlet side of the prefilter. Pull out slightly to ensure a solid connection.
- Push John Guest quick connect end of (D) John Guest to Clack 1” Stainless Flex Pipe on to the outlet Male Stem of the prefilter. Pull out slightly to ensure a solid connection.
- Attach Clack quick connect end of (D) John Guest to Clack 1” Stainless Flex Pipe to inlet side of Carbon Tank Bypass. Hand tighten only.
- Attach Clack quick connect end of (E) Clack to Clack 1” Stainless Flex Pipe to outlet side of Carbon Tank Bypass. Hand tighten only.
- Attach second Clack quick connect end of (E) Clack to Clack 1” Stainless Flex Pipe to inlet side of Natursoft Tank Bypass. Hand tighten only.
- Attach Clack quick connect end of (F) Clack to Female Threaded 1” Stainless Flex Pipe to outlet side of NaturSoft Tank Bypass.Hand tighten only.
- Wrap (A) plumber’s tape two (2) to three (3) times around both threaded ends of UV chamber.
- Thread the female threaded end of (F) Clack to Female Threaded 1” Stainless Flex Pipe to the inlet threaded connection on the UV system. Hand tighten and follow with one (1) to two (2) turns with wrench.
- Thread the female threaded end of the (G) Female Threaded to John Guest 1” Stainless Flex Pipe to outlet threaded connection on UV. Hand tighten and follow with one (1) to two (2) turns with wrench.
- Push John Guest connection end of (G) Female Threaded to John Guest 1” Stainless Flex Pipe on to water line going into the home. Pull out slightly to ensure a proper connection.
Special Note for PVC Customers:
John Guest fittings will only connect to Copper, cPVCand PEX. For your
convenience, we have included two (2) additional (C) John Guest 1” NPT to Stem
fittings to convert your PVC pipes to the Installation Kit. Simply insert the
stem ends of each fitting into the John Guest Ends of the Flex Pipe and inlet
side of the
prefilter, then thread your PVC to the Male threaded NPT ends of the Stem
fittings.