FEIT Electric GLP24ADJS 24 Inch 19 Watt Selectable Spectrum LED Grow Light Instruction Manual
- June 10, 2024
- Feit Electric
Table of Contents
MODEL GLP24ADJS/19W/LED
LED UTILITY LIGHT INSTALLATION INSTRUCTIONS
GLP24ADJS 24 Inch 19 Watt Selectable Spectrum LED Grow Light
WARNING: IMPROPERLY INSTALLING OR ATTACHING THESE PRODUCTS IN ANYWAY MAY A• RESULT IN A POSSIBLE SHOCK OR FIRE HAZARD. PRODUCTS SHOULD BE INSTALLED IN ACCOR- DANCE WITH THE OWNERS MANUAL, CURRENT ELECTRICAL CODES AND/OR THE CURRENT NATIONAL ELECTRIC CODE (NEC).
PARTS INCLUDED
IMPORTANT SAFETY INSTRUCTIONS -This portable light-emitting-diode (LED)
luminaire has a polarized plug (one blade is wider than the other) as a
feature to reduce the risk of electric shock. This plug will properly fit in a
polarized outlet in only one way. If the plug does not fit squarely in the
outlet, reverse the plug. If it still does not fit, contact a certified
electrician. Never use with an extension cord unless plug can be fully
inserted. Do not alter the plug.
THIS FIXTURE IS DESIGNED TO BE INSTALLED DIRECTLY BENEATH A CEILING-MOUNTED
RECEPTACLE EXCLUSIVELY.
LINKING MULTIPLE SHOPELIGHT
linkn up to 7 additinoal units max or 1.232A max dont overload
LIMITED WARRANTY
This product is warrantied to be free from defects in workmanship and
materials for up to 3 year from date of purchase. If the product falls within
the warranty period, please visit feit.com/help
for instructions on replacement/refund or call 866.326.BULB. REPLACEMENT OR
REFUND IS YOUR SOLE REMEDY. EXCEPT TO THE EXTENT PROHIBITED BY APPLICABLE LAW,
ANY IMPLIED WARRANTIES ARE LIMITED IN DURATION TO THE DURATION OF THIS
WARRANTY. LIABILITY FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES IS HEREBY
EXPRESSLY EXCLUDED. Some states and provinces do not allow the exclusion of
incidental or consequential damages, so the above limitation or exclusion may
not apply to you. This warranty gives you specific legal rights, and you may
also have other rights which vary from state to state or province to province.
Supplier’s Declaration of Conformity: 47 CFR 9 2.1077 Compliance
Information Responsible Party: Feit Electric Company 4901 Gregg Road, Pico
Rivera, CA 90660, USA 562-463-2852
Unique Identifier. GLP24ACUS/19W/LED
This device complies with part 15 of the FCC Rules. Operation is subject to
the following two conditions:
- This device may not cause harmful interference, and
- this device must accept any interference received, including interference that may cause undesired operation.
Note: This equipment has been tested and found to comply with the limits
for a Class B digital device, pursuant to part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates, uses and
can radiate radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not
occur in a
particular installation. If this equipment does cause harmful interference to
radio or television reception, which can be determined by turning the
equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures: Reorient or relocate
the receiving antenna. Increase the separation between the equipment and
receiver. Connect the equipment into an outlet on a circuit different from
that to which the receiver is connected. Consult the dealer or an experienced
radio/TV technician for help. Any changes or modifications not expressly
approved by the manufacturer could void the user’s authority to operate the
equipment. CAN ICES-005 (B)
WARNING: TURN OFF THE MAIN POWER ATTHE CIRCUIT BREAKER BEFORE INSTALLING THE FIXTURE IN ORDER TO PREVENT POSSIBLE ELECTRIC SHOCK.
INSTALLATION OPTIONS
Install fixture using included chain and V-hooks
- Install provided screw-hooks directly onto ceiling. Spacing between screws should be 23.5 inches (See Figure A). For concrete ceilings/drywalls, wall anchors are required. Drill two holes for provided wall anchors then use provided screw hooks (See Figure 1). 2. Attach chain to V-hooks then Insert hooks into mounting holes located on top of fixture (See Figure
- Do this for both ends of the fixture.
- Install fixture to ceiling by hanging the chain to pre-mounted screw-hooks on ceiling (See Figure 3).
- Plug in power-cord to outlet or connect to additional GLP24ADJS/19W/LED shoplights.
- Push the power button to turn fixture ON/OFF.
- Zip tie cord to chain (see Figure 4)
Install fixture flushmount using screws
- Install provided screws directly onto mounting surface. Spacing between screws should be 22.24 inches. Gap (D) should be .079-.099 inches. For concrete/drywall surfaces, wal I anchors are required. Drill two holes for provided wall anchors then use provided screws (See Figure 5).
- Install fixture to mounting surface by inserting the Key Holes on top side of the fixture into the mounting screws (See Figure 6). It may be necessary to adjust the tightness of the screws (Gap 0). Make sure both screws hold the lamp securely on the narrow side of the Key Holes.
- To better secure the fixture, mount a third screw next to the side of the outlet (See Figure 7). If anchor is required, mark the hole as close as possible to the fixture, remove the lamp, drill the hole on the marked position, install anchor into the drilled hole, re-install the fixture then install the screw into the wall anchor.
- Plug in power-cord to outlet or connect to additional GLP24ADJS/19W/LED shoplights.
- Push the power button to turn fixture ON/OFF.
Fixture Maintenance
- Please make sure the power is off before maintenance.
- To avoid any damage to the product, clean fixture with a soft, damp cloth. Do not use chemical solvents.
- To ensure better lighting, please clean the lamp regularly.
Using the Grow Lights
Recommended Light to Plant Distance
Plant types are generally categorized into high or low light level plant
categories. The PAR value of a plant light equates to the amount of light
energy that a plant can absorb. The higher the PAR, the more intense the light
energy a plant can absorb facilitating accelerated vegetative and/or flowering
growth. Below are the plant types and recommended optimal light energy
absorption distances based on this LED Grow Light:
High light plants
Tomatoes, peppers, perennials, etc. Seedlings Stage — 6 in. through 2 weeks of
vegetative stage Vegetative and/or Flowering Stage — 16-30 in.
Low light plants
Herbs and leafy greens (such as basil lettuce). Seedlings Stage — 12 in.
through 2 weeks of vegetative stage Vegetative and/or Flowering Stage — 24-30
in.
- The height is the distance between the light source to the top of the plant. Increase the height of the telescoping post if dry spots on the plant begin to form. **Growth cycle depends on the type of plant.
Plants in Seedling Growth Stage
- The recommended growth cycle is 16 or more hours of light a day.
- Seeds typically germinate in five to 10 days given optimal conditions. You’ll know seeds have germinated as soon as you see a green plant emerging from the soil.
- The plant is now in the seedling stage. The time in this stage is two to three weeks.
Plants in Vegetative Growth Stage
- The recommended growth cycle is 18 hours of light during the vegetative growth stage. This light cycle will create an environment that mimics the photoperiod in the summer with long days. It is during the vegetative growth stage that cloning, transplanting, pruning, and bending are all initiated.
- Turn your LED grow light ON for 18 hours a day and then turn the light OFF and leave your plant in the dark for another six hours. Most plants will need four to six weeks in the vegetative cycle before reaching the flowering stage.
Plants in Budding and Flowering Growth Stage
- Pre-flowers are the first indication that the plant is ready to move into the budding and/or flowering stage of growth.
- The pre-flowers grow at branch intemodes just behind the leaf spur typically around the fourth week of vegetative growth, when the plant is six to eight weeks old.
- When you start seeing pre-flowers forming this means that the plants are ready to go into the flowering stage. You can continue to grow in the vegetative growth stage or switch to flowering at this point. The pre-flower looks like a regular female flower with white fuzzy pistils. The pre-flowering can take from one to two weeks.
- Wait to induce flowering until pre-flowers have appeared. Induce flowering by switching your light cycle to 12 hours of uninterrupted darkness and 12 hours of light.
Notes:
- If LED grow light is installed as a flush mount fixture under a cabinet orcanopy where distance cannot be adjusted, mount at the min of 24″ distance.
- If LED grow light can be hung from a ceiling, cabinet orcanopy, use the supplied hanging assembly or purchase a chain separately to adjust height of LED light to maintain the recommended distances as the plant grows.
- For taller plants including tomatoes, mounting one (1) grow light overhead and one (1) grow light as a side light on eitherside of the plant will provide additional supplemental light supporting fuller plant growth fora bushy plant.
FEIT ELECTRIC COMPANY
PICO RIVERA, CA 800-543-3348
www.feit.com
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>