Schneider Electric TPRS-065 TeSys Active Starters and Power Interface Modules Instruction Manual

June 10, 2024
Schneider Electric

TPRS-065 TeSys Active Starters and Power Interface Modules
Instruction ManualSchneider Electric TPRS-065 TeSys Active Starters and
Power Interface Modules TeSys™ Active
TPRS•065 / TPRS•080 / TPRPM080 Starters and Power Interface Modules, Size 3

TPRS-065 TeSys Active Starters and Power Interface Modules

DANGER

HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH

  • Read and understand this document and the documents listed on page 3 before installing, operating, or maintaining your TeSys Active.
  • This equipment must only be installed and serviced by qualified electrical personnel.
  • Turn off all power supplying this equipment before mounting, cabling, or wiring this equipment.
  • Use only the specified voltage when operating this equipment and any associated products.
  • Power line circuits must be wired and protected in compliance with local and national regulatory requirements.
  • Apply appropriate personal protective equipment (PPE) and follow safe electrical work practices per local and national regulatory requirements.

Failure to follow these instructions will result in death or serious injury.
WARNING: This product can expose you to chemicals including Antimony oxide (Antimony trioxide), which is known to the State of California to cause cancer. For more information go to www.P65Warnings.ca.gov.

WARNING

HAZARD OF FIRE

  • Use only the specified wire gauge with the equipment and comply with the specified wire termination requirements.
  • Tighten the power line connections in conformance with the torque specifications.

SHORT CIRCUIT HAZARD
Identify shorted Everlink™ terminals with the provided sticker and only use or reuse them for wye-delta applications.
Failure to follow these instructions can result in death, serious injury, or equipment damage.

WARNING
UNINTENDED EQUIPMENT OPERATION

  • Do not disassemble, repair, or modify this equipment. There are no user serviceable parts.
  • Install and operate this equipment in an enclosure appropriately rated for its intended environment.
  • Always route communication wiring and power wiring separately.
  • For complete instructions about the functional safety modules, refer to the Functional Safety Guide, 8536IB1904

Failure to follow these instructions can result in death,serious injury, or equipment damage.
PLEASE NOTE

  • Electrical equipment should be installed, operated, serviced, and maintained only by qualified personnel.
  • No responsibility is assumed by Schneider Electric for any consequences arising out of the use of this material.

Documentation

  • 8536IB1901, System Guide
  • 8536IB1902, Installation Guide
  • 8536IB1903, Operating Guide
  • 8536IB1904, Functional Safety Guide
    Available at www.se.com.

Functional Safety Compliance

Schneider Electric TPRS-065 TeSys Active Starters and Power Interface
Modules - FeaturesA. Flat cable
B. LED status indicators
C. Accessory attachment connection
D. Everlink terminals
E. Flat cable connection
F. QR code
G. Name tag
H. Mobile bridge

Coupling Starters

Schneider Electric TPRS-065 TeSys Active Starters and Power Interface
Modules - Coupling Starters 1 DisassemblySchneider Electric TPRS-065
TeSys Active Starters and Power Interface Modules - Coupling Starters
2 For 2 direction and 2 speed avatars. See Installation Guide, 8536IB1902, for applications.Schneider Electric TPRS-065 TeSys Active Starters and Power
Interface Modules - Coupling Starters 3

DisassemblySchneider Electric TPRS-065 TeSys Active Starters and Power
Interface Modules - Coupling Starters 4 For Y/D avatars. See Installation Guide, 8536IB1902, for applications.

Mounting

Schneider Electric TPRS-065 TeSys Active Starters and Power Interface
Modules - MountingSchneider Electric TPRS-065 TeSys Active Starters and Power
Interface Modules - Mounting 1

Cabling

Schneider Electric TPRS-065 TeSys Active Starters and Power Interface
Modules - Mounting 1

| | Schneider Electric TPRS-065 TeSys Active Starters and Power Interface
Modules - Cabling 3| |
---|---|---|---|---
16 mm| 1–35 mm²| 2 x (1–25 mm² )| 1–25 mm²: 5 N●m
35 mm²: 8 N●m| 4 mm
0.16 in.
0.63 in.| AWG 16–2| 2 x (AWG 16–4)| AWG 16–4: 44 lb-in
AWG 2: 70 lb-in

Group Motor Short-Circuit Ratings

| Circuit Protection| | kA
---|---|---|---
TPRS•065| GV3P651| 480 Y / 277 V| 50
GV3P651| 600 Y / 347 V| 25

1 960 in3 (15731 cm3) = Minimum enclosure volume
Schneider Electric Industries SAS
35, rue Joseph Monier
CS30323
F – 92500 Rueil-Malmaison
www.se.com
**** Printed on recycled paper.

Schneider Electric Limited
Stafford Park 5
**** Telford, TF3 3BL
United Kingdom
www.se.com/uk
MFR77085-08 © 2022 Schneider Electric All rights reserved

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Schneider Electric User Manuals

Related Manuals