CHAUVET PROFESSIONAL PowerStream 4 IP Splitter User Guide

June 10, 2024
Chauvet Professional

CHAUVET PROFESSIONAL PowerStream 4 IP Splitter

CHAUVET-PROFESSIONAL-PowerStream-4-IP-Splitter-product

PowerStream 4 IP Quick Reference Guide

About This Guide

The PowerStream 4 IP Quick Reference Guide (QRG) provides basic product information such as mounting and connection instructions.

Disclaimer

The information and specifications in this QRG are subject to change without notice.

Limited Warranty

Safety Notes

Before mounting or using this product, please read the safety notes included in the user manual.

Contact

If you need support or wish to return a product, please contact your distributor if you’re outside the U.S., U.K., Ireland, Benelux, France, Germany, or Mexico. Refer to the “Contact Us” section at the end of this guide for contact information.

Overview

The PowerStream 4 IP is a power distribution unit that allows multiple devices to be powered from a single power source. It includes four power output connectors and one power input connector. The product also features a carry handle, safety cable, and mounting clamp for easy and safe installation.

Technical Specifications

  • Dimensions (L x W x H): 10.81 in x 3 in x 2.68 in
  • Weight: 3 lb
  • Input Voltage: Auto-Ranging
  • Maximum Pass-Through Current: 16A
  • Power Input Connector: TRUE1 style Compatible Seetronic PowerKon IP65
  • Power Output Connector: TRUE1 style Compatible Seetronic PowerKon IP65 (x4)
  • Item Code: 09081276
  • UPC Number: 781462216245

Product Usage

AC Power Setup

  1. Plug a power cord into the power input connector.
  2. Plug any additional products into the power output connectors.
  3. Additional PowerStream 4 IP products can be daisy-chained by plugging them into any empty power output connector.
  4. Ensure that the total current of all devices connected through the PowerStream 4 IP does not exceed 16A.

Mounting Instructions

Before mounting the product, please read the safety notes included in the user manual. Follow these steps to mount your PowerStream 4 IP:

  1. Attach the mounting clamp to a secure surface using screws or other fasteners appropriate for the surface material.
  2. Attach the safety cable to the mounting clamp and then to the carry handle on the PowerStream 4 IP.
  3. Place the PowerStream 4 IP onto the mounting clamp and secure it with screws or other fasteners provided with the mounting clamp.

Ordering Information

The PowerStream 4 IP can be ordered using its item code (09081276) or UPC number (781462216245).

Contact Us

Please contact your distributor for support or returns if you’re outside the U.S., U.K., Ireland, Benelux, France, Germany, or Mexico. For all other inquiries, please contact us at support@powerstream.com.

About This Guide

The PowerStream 4 IP Quick Reference Guide (QRG) has basic product information such as mounting and connection.

Disclaimer

The information and specifications contained in this QRG are subject to change without notice.

LIMITED WARRANTY

FOR WARRANTY REGISTRATION AND COMPLETE TERMS AND CONDITIONS PLEASE VISIT OUR WEBSITE. For Customers in the United States and Mexico: www.chauvetlighting.com/warranty-registration.

For Customers in the United Kingdom, Republic of Ireland, Belgium, the Netherlands, Luxembourg, France, and Germany: www.chauvetlighting.eu /warranty-registration.

Chauvet warrants that this product shall be free from defects in material and workmanship under normal use, for the period specified in, and subject to the exclusions and limitations set forth in the full limited warranty on our website. This warranty extends only to the original purchaser of the product and is not transferable. To exercise rights under this warranty, you must provide proof of purchase in the form of an original sales receipt from an authorized dealer that shows the product name and date of purchase. THERE ARE NO OTHER EXPRESS OR IMPLIED WARRANTIES. This warranty gives you specific legal rights. You may also have other rights that vary from state to state and country to country. This warranty is valid only in the United States, United Kingdom, Republic of Ireland, Belgium, the Netherlands, Luxembourg, France, Germany and Mexico. For warranty terms in other countries, please consult your local distributor.

Safety Notes

These Safety Notes include important information about installation, use, and maintenance.

  • DO NOT open this product. It contains no user-serviceable parts.
  • To eliminate unnecessary wear and improve its lifespan, during periods of non-use completely disconnect the product from power via breaker or by unplugging it.
  • CAUTION: When transferring product from extreme temperature environments, (e.g. cold truck to warm humid ballroom) condensation may form on the internal electronics of the product. To avoid causing a failure, allow product to fully acclimate to the surrounding environment before connecting it to power.
  • CAUTION: This product’s housing may be hot when lights are operating.
  • Mount this product in a location with adequate ventilation, at least 20 in (50 cm) from adjacent surfaces.
  • DO NOT leave any flammable material within 1.97 in (5 cm) of this product while operating or connected to power.
  • USE a safety cable when mounting this product overhead.
  • DO NOT submerge this product (IP65). Regular outdoor operation is fine.
  • DO NOT operate this product if the housing or cables appear damaged.
  • ONLY connect this product to a grounded and protected circuit.
  • In the event of a serious operating problem, stop using immediately.

Contact
Outside the U.S., U.K., Ireland, Benelux, France, Germany, or Mexico, contact your distributor to request support or return a product. Refer to Contact Us at the end of this QRG for contact information.

What is Included

  • PowerStream 4 IP
  • Quick Reference Guide

Product Overview

CHAUVET-PROFESSIONAL-PowerStream-4-IP-Splitter-fig
1

AC Power
This product can work with an input voltage range of 100–240 VAC, 50/60 Hz.

Setup

  1. Plug a power cord in to the power input.
  2. Plug any additional products in to the power outputs.
  3. Additional PowerStream 4 IP products can be daisy chained by plugging in to any empty power output.
    • Do not exceed 16 amps throughout the entire power run.
    • The maximum load for the PowerStream 4 IP is 16 amps. Do not exceed this rating.
    • The maximum current for any power output on the PowerStream 4 IP is 16 amps. Do not exceed this rating.

Mounting

Before mounting this product, read the Safety Notes.

Mounting DiagramCHAUVET-PROFESSIONAL-PowerStream-4-IP-Splitter-fig
2

Product Technical Specifications

Dimensions and WeightCHAUVET-PROFESSIONAL-PowerStream-4-IP-Splitter-fig
3

Note: Dimensions in inches are rounded.
PowerCHAUVET-PROFESSIONAL-PowerStream-4-IP-Splitter-fig
4

OrderingCHAUVET-PROFESSIONAL-PowerStream-4-IP-Splitter-fig
5

Contact Us

Chauvet World Headquarters

Address: 5200 NW 108th Ave. Sunrise, FL 33351
Voice: 954-577-4455
Fax: 954-929-5560
Toll Free: 800-762-1084

Technical Support

Voice: 844-393-7575
Fax: 954-756-8015
Email: chauvetcs@chauvetlighting.com
Website: www.chauvetprofessional.com

Chauvet Europe Ltd.

Address: Unit 1C
Brookhill Road Industrial Estate Pinxton, Nottingham, UK NG16 6NT
Voice: +44 (0) 1773 511115
Fax: +44 (0) 1773 511110

Email: UKtech@chauvetlighting.eu
Website: www.chauvetprofessional.eu

Chauvet Europe BVBA

Address: Stokstraat 18 9770 Kruishoutem Belgium
Voice: +32 9 388 93 97
Email: BNLtech@chauvetlighting.eu
Website: www.chauvetprofessional.eu

Visit the applicable website above to verify our contact information and instructions to request support. Outside the U.S., U. K., Ireland, Mexico, France, Germany, or Benelux, contact the dealer of record.

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Chauvet Professional User Manuals

Related Manuals