Infralan FTPS600 Field Mountable Plug Instruction Manual
- June 4, 2024
- Infralan
Table of Contents
Infralan FTPS600 Field Mountable Plug
Instruction Manual
| TIA/EIA
T568A
| TIA/EIA
T568B
| INDUSTRIAL|
---|---|---|---|---
White/Green
Green
| White/Orange Orange| Yellow Orange|
|
White/Orange Orange| White/Green Green| White
Blue
|
Blue White/Blue
White/Brown
Brown
| Blue White/Blue
White/Brown
Brown
| |
-
Remove the stopper before installation. f Cover S topper
-
Insert cable into strain relief boot, strip off 1.2inch of cable jacket, fold back braid and drain wire
-
Trim the ends of conductors.
-
Remove the wiring label before place wiring cap on plug. Fan out all four twisted pairs, following the color coding label and allocate each conductor into proper slots on wiring cap
-
Place the wiring cap onto plug, use plier to clamp wiring cap until it completely snap-in to effect the connection.
-
Close plug cover, make sure the drain wire is in proper contact with grounding clip on plug.
Pull back strain relief boot to cover the plug, fasten supplied cable tie to secure grounding contact.
Unload the cable Cut off cable tie, remove the boot. Using flat screw driver and pry gently on plug cover one end first and the other end subsequently to open it.
Unload the cable
Cut off cable tie, remove the boot. Using flat screw driver and pry gently on
plug cover one end first and the other end subsequently to open it.
Boot adjustment
Cut the end of boot to fit your cable OD