renkforce 1529145 750W Stainless Steel Clear Water Pump Instruction Manual

June 10, 2024
renkforce

renkforce 1529145 750W Stainless Steel Clear Water Pump Instruction Manual
renkforce 1529145 750W Stainless Steel Clear Water
Pump

Introduction

Dear Customer,
thank you for purchasing this product. This product complies with the statutory national and European requirements. To maintain this status and to ensure safe operation, you as the user must observe these operating instructions! These operating instructions are part of this product. They contain important notes on commissioning and handling. Also consider this if you pass on the product to any third party. Therefore, retain these operating instructions for reference!

If there are any technical questions, please contact:
www.conrad.com/contact

Explanation of Symbols

 The symbol with a lightning bolt in a triangle is used where there is a health hazard, e.g. from electric shock.
 The exclamation mark in a triangle indicates important notes in these operating instructions that must be observed strictly.
The arrow symbol indicates that special advice and notes on operation are provided.

Intended Use

The clear water pump is intended for private use, e.g. in a hobby garden. The product is not intended for operation of irrigation or irrigation systems in commerce, industry or public areas (e.g. garden facilities). Only clear, clean fresh water is admissible as conveyed liquid. The conveyed liquid must not be hotter than +35 °C. The clear water pump is used, e.g., recirculate/drain containers (rain water cistern), water supply of suitable devices in the garden via a house well (ground water) or pumping off water, e.g. from a swimming pool. A, external float switch activates the clear water pump automatically when the water level rises. The float switch can, however, be attached to the clear water pump side if not in use. These operating instructions must be passed on to any person who uses the clear water pump. The clear water pump must only be used if these operating instructions have been read and understood. The safety notes and all other information in these operating instructions always have to be observed. Any use other than that described above can damage the product and may involve additional risks such as short circuit, fire, electric shock, etc. No part of this product must be modified or converted! This product complies with the statutory national and European requirements. All company names and product names are trademarks of their respective owners. All rights reserved.

Scope of Delivery

  • Clear water pump
  • Thread connection piece
  • Hose connection
  • Operating instructions

Current operating instructions
Download the current operating instructions via the link www.conrad.com/downloads or scan the QR code displayed. Observe the instructions on the website.

Safety Information

The guarantee/warranty will expire if damage is incurred resulting from non compliance with these operating instructions. We do not assume any liability for consequential damage!
Nor do we assume any liability for damage to property or personal injury caused by improper use or failure to observe the safety information. The warranty/guarantee will expire in such cases!

a) General Information

  • For safety and licensing reasons, unauthorised conversion and/or modifications to the product are not  permitted. Furthermore, this will render the guarantee/warranty void!
  • The product is not a toy. Children cannot judge the dangers involved when handling electrical devices.
  • The product corresponds to protection type IPX8.
  • The product is designed according to protection class I. Only a proper protective contact mains socket of the public mains must be used as a voltage source (for the operating voltage of the clear water pump, see chapter „Technical Data“).
  • Do not leave the packaging material lying around carelessly as it can become a dangerous toy for children.
  • Handle the product with care. It can be damaged by impact, blows or when dropped even from a low height.

b) Site of Setup, Connection

  • Install or operate the product in a way that it is out of reach of children.
  • Using the product in or close to garden ponds, wells, swimming pools, fountains, etc. is only permissible if the product is operated by a leakage current protection switch (FI protection switch) with a nominal error current of <=30 mA). If persons are present in a pool, swimming pond or garden pond, the product must not be operated in it. In Austria, the product must only be installed and operated in or close to swimming pools and garden ponds if a suitable ÖVE-tested safety separating transformer is switched in front of it in addition to the leakage current protection switch.
  • There must not be any ambience temperatures around or below freezing (<0 °C) at the operating site. The water in the clear water pump would freeze and the higher volume of ice destroys the clear water pump. Store the product dry and protected from frost in winter.
  • If you are using an extension cord or if placement of cables to the clear water pump is required, these cables must not have a cross section of less than the clear water pump‘s. Only use extension lines with protective ground that are suitable for outdoor use.
  • Protect the mains line of the clear water pump against cold/heat, oil/gasoline and sharp edges; do not step on the mains line, do not drive on it (e.g. wheelbarrow, bicycle, car). Do not bend the mains line and do not place any objects on it.
  • Ensure that electrical plug connections are in flooding-safe areas; otherwise, there is a danger to life from electric shock! If required, use suitable protective housings for the plug connections.
  • Protect the mains plug from wetness! Never touch the mains plug with wet hands! There is danger to life from electric shock!
  • The mains cable or mains plug must not be cut off

c) Operation

  • The product must not be operated by children or teens. This also applies regarding persons who are not familiar with these operating instructions. Persons with limited physical or mental capacities must only use the product if supervised and instructed by a person responsible for them.

  • Only clear, clean fresh water with a temperature of no more than 35 °C must be conveyed.

  • The conveyed liquid must be clean. The build of the clear water pump permits contamination only up to a grain size of 5 mm.

  • The product is not suitable for conveying potable water.

  • The product is not suitable for conveying corrosive/caustic, flammable or explosive liquids (e.g. gasoline, fuel oil, nitro diluent), grease, oils, salt water or sewage from toilets.

  • The mains socket to which the clear water pump is connected must be easily accessible. The mains cable must point downwards from the mains socket so that the water running back at the cable cannot enter the mains socket.

  • If the clear water pump is to be operated, e.g., in a well, it must be suitably attached, e.g. with a rope. The rope must be able to hold at least 3 times the weight of the clear water pump for reasons of safety. Never attach the clear water pump via its mains cable; also never use the mains cable to carry, hold or submerse the clear water pump!

  • The product is not protected against running dry.

  • The product must not be operated unsupervised.

  • The product must not work in permanent operation.

  • No persons must be present in the conveyed medium during operation.

  • The product must not be operated in or close to explosive liquids or gases; there is a danger of explosion!

  • Consequential damage caused by malfunction or interference at the clear water pump must be prevented by suitable measures (e.g. water level indicator, sensors, alarm devices, backup pump, etc.).

  • The product is only suitable for use in temperate, not tropical, climates.

  • Do not shut off the outlet side of the clear water pump when it is in operation. Use, e.g., a corresponding pressure switch to switch off power supply to the clear water pump in time.
    The clear water pump pressure must not work against the closed pressure side for more than 5 minutes to prevent damage. The water present in the clear water pump will heat up even during these 5 minutes. When the pressure side is opened, hot water will escape; danger of scalding/injury!

  • Do not put the product with the intake openings directly into sludgy, sandy or stony ground, e.g. at the bottom of a garden pond. Use, e.g., a stone plate as a basis. Otherwise, the intake openings may be fully or partially blocked even after a short time! Sand, small stones or other hard objects in the conveyed liquid will otherwise lead to increased wear and reduction of performance of the clear water pump.

  • Check the entire product for damage before any commissioning, e.g. damage to the casing and mains cable/plug. If you find any damage, the product must not be used. If the product is already connected to the mains voltage, first switch off all contacts of the associated mains socket by deactivating the circuit breaker or turning out fuse; then switch off the associated FI protection switch. Only now unplug the clear water pump mains plug from the mains socket. Do not operate the product anymore afterwards, but take it to a specialist workshop. Never perform any repairs on your own. Always leave them to a specialist!

  • If you have reason to believe that the clear water pump can no longer be operated safely, disconnect it immediately and make sure it is not unintentionally operated; pull the mains plug from the socket. It can be assumed that safe operation is no longer possible if:

    • the clear water pump or connection lines show visible damage
    • the clear water pump no longer works
    • the clear water pump has been transported or stored under difficult circumstances
    • if it was subjected to heavy stress during transport.
  • Always disconnect the mains plug from the mains socket when you are no longer using the product, for troubleshooting or for cleaning/maintenance.

  • Never pull the mains plug from the mains socket by pulling the cable. Always pull the mains plug from the mains socket by the lateral grip areas. Never touch the mains plug with wet or damp hands; danger to life from  electric shock!

  • Only transport the product at the carry handle but never at the mains cable.

  • If the product is brought from a cold into a warm room (e.g. in transport), it is possible that condensation develops. This causes danger to life from electric shock! Therefore, you should allow the product to warm up to room/ambience temperature before using it or connecting it to the mains voltage. This may take several hours.

Control Elements

OVERVIEW

  1. Mains cable with IP44 protective contact mains plug
  2. Outlet opening
  3. Carry handle (also suitable for attaching a rope for submersion of the clear water pump)
  4. Cable holder for the cable of the float switch
  5. Float switch
  6. Intake openings

Placement of the Clear Water Pump

  • Attach a sufficiently strong, water-tight rope to the carry handle to lower the clear water pump, e.g. into a well. The clear water pump must never be held or attached by the mains cable or the float switch! This may damage the mains cable; there is danger to life from electric shock! The clear water pump also must not be attached via the hose. Fasten the rope to a suitable holder. Never put the clear water pump with the intake opening into dirt, sludge or leaf residue, e.g. in a rain barrel, because this will clog the clear water pump. We recommend complying with a minimum distance of 30 cm above ground.
  • To connect the hose used by you to the clear water pump, you may use the enclosed connection piece and the hose connection.
  • There is a cable holder on the side of the carrying handle. It serves to fasten the cable to the float switch. The activation/deactivation water level will later result from the position in which the float switch cable is attached. Set the cable length that fits your site of use so that the float switch will switch the clear water pump on and off as desired.

Commissioning

  • After lowering the clear water pump into the well, etc. by a rope and fastening the rope accordingly, plug the mains plug into a properly installed protective ground mains socket. This must be an IP44 mains socket for operation in the outdoor area. The mains plug must only be plugged into the mains socket when dry. There is danger to life from electric shock otherwise!
  • When the float switch is placed correctly, the clear water pump will switch on and start taking in water and transporting it through the exit opening. If no water is conveyed, there is still air in the clear water pump and the hose. You may be able to accelerate the intake process if you fill water into the clear water pump or the hose, or if you move the clear water pump slightly back and forth.
  • The clear water pump switches off automatically if the float switch drops. The clear water pump can also be operated manually by fastening the float switch to the clear water pump by the cable holder accordingly or placing it higher. The clear water pump pressure pump must not be operated unsupervised then, because the clear water pump will not switch off if there is no water, which would damage the pump.

Decommissioning

If the clear water pump is to be disconnected from the hose (e.g. for cleaning, maintenance or storage in winter), proceed as follows:

  • Disconnect the clear water pump from the power supply, pull the mains plug from the mains socket.
  • Pull the clear water pump from the water by the attachment rope or carry handle. The clear water pump must never be pulled out by the mains cable, float switch or hose! This may damage the mains cable; there is danger to life from electric shock!
  • Disconnect the hose from the clear water pump.
  • Let residual water run out of the clear water pump by holding it diagonally or turning it upside-down.
  • Dry the clear water pump and the mains cable. Coil up the mains cable.
  • Store the clear water pump in a frost-protected and dry room over winter. Also consider emptying the hoses placed outdoors to prevent frost damage; open any water taps that may be installed.
  • Carry or transport the clear water pump only by the carry handle. Never hold it by the hose, the float switch or even the mains cable.
  • After operation or emptying, a small amount of water may be retained in the clear water pump. Therefore, use a suitable support when storing or transporting it in a vehicle.

Maintenance and Cleaning

The clear water pump has no parts that require maintenance by you. Therefore, never open or disassemble it. Maintenance or repair and opening of the clear water pump in this context must only be performed by a specialist or specialist workshop. Before cleaning, disconnect the clear water pump from the mains voltage; pull the mains plug from the mains socket. To clean the outside of the clear water pump, a dry, soft and clean cloth is sufficient. If required, flush the outside with clear water. Any contamination of intake openings may be removed under running water (e.g. garden hose). The clear water pump inside may be flushed with running water as well by removing the hose and any connection piece. Dry the clear water pump and the mains cable before storing it.

 Never use any aggressive cleaning agents, cleaning alcohol or other chemical solutions, since these may damage the casing or even impair function.

Troubleshooting

With this clear water pump, you purchased a product built to the state of the art and operationally safe. Nevertheless, problems or errors may occur. Therefore, observe the following information about troubleshooting.

Clear water pump does not take in water

  • Open any present shut-off valve on the pressure-side, since air cannot escape from the hose or in the pump. Move the pump back and forth a little. If required, fill water into the clear water pump or the hose. Briefly pull the mains plug from the socket and plug it back in.
  • Clean intake openings (disconnect clear water pump from the mains voltage first!).
  • The water level is too low or air is sucked in as well.

The clear water pump does not start up or stops in operation

  • Check the power supply or the circuit protection and the FI protection switch. If the FI protection switch has triggered, disconnect the clear water pump from the mains voltage and check for damage (e.g. mains cable).
  • The pump wheel inside the clear water pump is blocked by dirt. Disconnect the clear water pump from the mains voltage, remove the hose and flush the inside of the clear water pump with water.
  • The float switch has not been placed correctly.
  • The overtemperature protection triggered. Disconnect the clear water pump from the mains voltage and let the clear water pump cool off (at least 30 minutes). Remove the cause for triggering (e.g. water temperature too high, running dry too long, etc.).

Conveyed volume reduces or is too low

  • Check the intake openings for contamination.
  • The clear water pump sucks in air because the intake openings are no longer completely submersed.
  • Check the attachment of the hose to the clear water pump.
  • Check the hose for leaks or bends.
  • The displacement reduces due to the principle the larger the conveyor height.
  • The hose diameter is too low.

Float switch does not trigger or does not switch off

  • The float switch has not been placed correctly.
  • Connect cable to the float switch to the side at the cable holder so that the float switch switches off correctly when a low water level is reached, e.g. in a cistern.

 Disposal

Electronic devices are recyclable and should not be disposed of in household waste. Dispose of the product according to the applicable statutory provisions at the end of its service life.

Technical Data

Operating voltage ……………………………………… 230 V/AC, 50 Hz
Protection class ………………………………………… I
Protection type ………………………………………….. IPX8
Nominal power (P1) …………………………………… 750 W
Output power (P2) …………………………………….. 550 W
Self-priming ……………………………………………… no
Overtemperature protection ………………………… yes
Running-dry protection ………………………………. no
Connection cable ……………………………………….H05RN-F, 3 x 1 mm², length approx. 10 m
Immersion depth ………………………………………..max. 7 m
Conveying height ……………………………………….max. 8.5 m
Conveyed volume ………………………………………max. 11000 l/h (depending on the conveyed height)
Conveyor medium ……………………………………..Clear, clean fresh water
Grain size/contamination …………………………….max. 5 mm
Conveyor agent temperature ……………………….max. +35 °C
Connection thread …………………………………….. 39 mm (1 1/4“) IG
Dimensions (Ø x H) …………………………………… 147 x 305 mm
Weight …………………………………………………….. approx. 5.35 kg (incl. cable)

This is a publication by Conrad Electronic SE, Klaus-Conrad-Str. 1, D-92240 Hirschau (www.conrad.com). All rights including translation reserved. Reproduction by any method, e.g. photocopy, microfilming, or the capture in electronic data processing systems require the prior written approval by the editor. Reprinting, also in part, is prohibited. This publication represent the technical status at the time of printing. Copyright 2022 by Conrad Electronic SE.

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals