Safety Notes
These Safety Notes include important information about installation, use, and maintenance of the Maverick Storm 2 Profile.
- The luminaire is intended for professional use only.
- The luminaire should be positioned so that prolonged staring into the luminaire at a distance closer than 6.56 ft (2 m) is not expected.
- If the external flexible cable or cord of this luminaire is damaged, it shall be replaced by a special cord or cord exclusively available from the manufacturer or its service agent.
- The light source contained in this luminaire shall only be replaced by the manufacturer or its service agent or a similar qualified person.
- CAUTION:
- This product’s housing may be hot when operating. Mount this product in a location with adequate ventilation, at least 20 in (50 cm) from adjacent surfaces.
- When transferring the product from extreme temperature environments, (e.g., cold truck to warm humid ballroom) condensation may form on the internal electronics of the product. To avoid causing a failure, allow the product to fully acclimate to the surrounding environment before connecting it to power.
- Flashing light is known to trigger epileptic seizures. User must comply with local laws regarding notification of strobe use.
- ALWAYS:
- Disconnect from power before cleaning the product or replacing the fuse.
- Replace the fuse with the same type and rating.
- Use a safety cable when mounting this product overhead.
- Connect this product to a grounded and protected circuit.
- DO NOT :
- Open this product. It contains no user-serviceable parts.
- Look at the light source when the product is on.
- Leave any flammable material within 20 cm of this product while operating or connected to power.
- Connect this product to a dimmer or rheostat.
- Operate this product if the housing, lenses, or cables appear damaged.
- Submerge this product (IP65). Regular outdoor operation is fine.
- Permanently install outdoors in locations with extreme environmental conditions. This includes, but is not limited to:
- Exposure to a marine/saline environment (within 3 miles of a saltwater body of water).
- Locations where normal temperatures exceed the temperature ranges in this manual.
- Locations that are prone to flooding or being buried in snow.
- Other areas where the product will be subject to extreme radiation or caustic substances.
- ONLY use the hanging/mounting bracket to carry this product.
- The maximum ambient temperature is 113 °F (45 °C). Do not operate this product at higher temperatures.
- The minimum startup temperature is -4°F (-20°C). Do not start the product at lower temperatures.
- The minimum ambient temperature is -22°F (-30°C). Do not operate the product at lower temperatures.
- To eliminate unnecessary wear and improve its lifespan, during periods of non-use completely disconnect the product from power via breaker or by unplugging it.
- In the event of a serious operating problem, stop using immediately.
FCC Compliance
This device complies with Part 15 Part B of the FCC rules. Operation is subject to the following two conditions:
- This device may not cause harmful interference, and
- This device must accept any interference received, including interference that may cause undesired operation.
Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
RF Exposure Warning for North America, and Australia
Warning! This equipment complies with FCC radiation exposure limits set
forth for an uncontrolled environment. This equipment should be installed and
operated with a minimum distance of 20cm between the radiator and your body.
This transmitter must not be co-located or operating in conjunction with any
other antenna or transmitter.
What is Included
- Maverick Storm 2 Profile
- Sermonic Power on IP65 power cord
- 2 omega brackets with mounting hardware
- Quick Reference Guide
AC Power
This product has an auto-ranging power supply that can work with an input voltage range of 100240 VAC, 50/60 Hz.
AC Plug
Connection | Wire (U.S.) | Wire (Europe) | Screw Color |
---|---|---|---|
AC Live | Black | Brown | Yellow/Brass |
AC Neutral | White | Blue | Silver |
AC Ground | Green/Yellow | Green/Yellow | Green |
To eliminate unnecessary wear and improve its lifespan, during periods of non- use completely disconnect the product from power via breaker or by unplugging it.
Mounting
Before mounting this product, read the Safety Notes. Use at least 2 mounting points per product. Make sure the mounting clamps are capable of supporting the weight of the product. For our Chauvet line of mounting clamps, go to http:// trusst.com/productcategory/truss- clamps.
Mounting Diagram
Control Panel Description
Button | Name | Function |
---|---|---|
< UP> | Navigates upwards through the menu list or increases the numeric |
value when in a function
| < MENU>| Exits from the current menu or function
| < DOWN>| Navigates downwards through the menu list or decreases the
numeric value when in a function
| < LEFT>| Navigates leftwards through the menu list
| < ENTER>| Enables the currently displayed menu or sets the currently
selected value into the selected function
| < RIGHT>| Navigates rightwards through the menu list
Contact Us
General Information | Technical Support |
---|
Chauvet World Headquarters
Address: 3360 Davie Rd. Davie, FL 33314
Voice: 954-577-4455 Fax:
954-929-5560
Toll Free: 800-762-1084| Voice:
844-393-7575 Fax:
954-756-8015
Email: chauvetcs@chauvetlighting.com
Website: www.chauvetprofessional.com
Chauvet U.K.
Address: Unit 1C
Brook hill Road Industrial Estate Panton, Nottingham,
UK NG16 6NT
Voice: +44 (0) 1773 511115 Fax: +44 (0) 1773 511110| Email:
UKtech@chauvetlighting.eu
Website: www.chauvetprofessional.eu
Chauvet Benelux
Address: Stokstraat 18 9770 Kruishoutem Belgium
Voice: +32 9 388 93 97| Email:
BNLtech@chauvetlighting.eu
Website: www.chauvetprofessional.eu
Chauvet France
Address: 3, Rue Ampère 91380 Chilly-Mazarin France
Voice: +33 1 78 85 33 59| Email:
FRtech@chauvetlighting.fr
Website: www.chauvetprofessional.eu
Chauvet Germany
Address: Bruno-Burgle-Str. 11 28759 Bremen Germany
Voice: +49 421 62 60 20| Email:
DEtech@chauvetlighting.de
Website: www.chauvetprofessional.eu
Chauvet Mexico
Address: Av. de las Partita’s 34 – 3B (Entrance by Calle 2)
Zona Industrial Lerma Lerma, Edo. de México, CP 52000
Voice: +52 728-690-2010| Email:
servicio@chauvet.com.mx
Website: www.chauvetprofessional.mx
Visit the applicable website above to verify our contact information and instructions to request support. Outside the U.S., U. K., Ireland, Mexico, France, Germany, or Benelux, contact the dealer of record.
Maverick Storm 2 Profile QRG Rev. 1
Documents / Resources
|
CHAUVET PROFESSIONAL Maverick Storm 2 Profile 580W LED Fixture
Light
[pdf] User Guide
Maverick Storm 2 Profile, 580W LED Fixture Light, Maverick Storm 2 Profile
580W LED Fixture Light, LED Fixture Light, Fixture Light
---|---
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>