Trina Solar TS4 Connector
Installation Manual
No: PS-M-0779
Version:F
Date:2021.10.12
Safety Instruction
The products may be installed only by suitably qualified and trained specialists with due observance of all applicable safety regulations. Trina Solar declines any liability in the event of failure to observe these warnings.
1.1.1 Use only the components and tools specified by Trina Solar. Do not
deviate from the preparation and assembly procedures described here, since in
this event, in the situation of self-assembly, no guarantee can be given as to
safety or conformity with the technical data. Do not modify the product in any
way.
1.1.2 Connector must be mated with connector qualified by Trina Solar,
otherwise Trina Solar will disclaim any warranty responsibility.
1.1.3 Do Not Disconnect under Load. Plugging and unplugging when life is
permitted, but the power at the PV system must be cut off.
1.2.1 Protection from electric shock must be assured by the end product and
its user.
1.2.2 To prevent electric shock, the system must be disconnected from the
power source when the connector is installed or disassembled.
1.2.3 The plug connection must not be subjected to a continuous mechanical
tension. The cable should be fixed with cable ties, avoiding any pull on the
connectors.
1.2.4 Do not place the plug connectors directly on the roof membrane.
1.3 Handling Safety
1.3.1 The connector is only applicable to the B and C types of copper wires
(see chapter 9 of NFPA NEC 70, table 10). It is recommended to use special
photovoltaic cable, tin-plated copper core, double insulation, and XLPE
insulating material. Trina prohibits the use of untinned cable PVC cables,
otherwise Trina Solar will disclaim any warranty responsibility.
1.3.2 Unmated plug connectors must be protected from moisture and dirt with a
sealing cap. If soiled, the male and female connectors must not be plugged
together.
1.3.3 The plug connectors are watertight in accordance with the IP68
protection class. However, they cannot be used for continuous operation
underwater.
1.3.4 Do not use in hydrocarbon, phenol, amine, and plastic corrosive
environment. The components must not be exposed to moisture due to direct
rainfall, condensation, etc. Ensure that the individual components do not come
into contact with acids, alkalis, gases, acetone, or other chemical substances
that could negatively impact the materials used. During the installation
process, do not add any grease and lubricant to the connector.
1.3.5 Below is the list of common chemicals that can affect the products. For
other chemicals not listed in the table, please confirm with Trina Solar
Technical Service
BEFORE use (see Section#8).
NO. | Chemical Name |
---|---|
1 | Lubricating oil |
2 | Rust-proof oil |
3 | Stamping oil |
4 | Grease |
5 | Engine oil |
6 | Diesel |
7 | Cooking oil |
8 | WD40 |
9 | Banana oil |
10 | Oil sealing agent |
11 | Ethyl acetate |
1.3.6 We recommend TS4 connector storage and transportation temperature
between -30℃ and +60℃ and relative humidity of less than 70%. Storage and
transportation at normal temperature must avoid direct sunlight, moisture, and
dust. It is not allowed to be stored with the affected chemicals. The plug
connectors should be installed within one year of delivery by Trina Solar.
1.3.7 Trina Solar has the right to make certain corrections for the printing
errors, improvements, and innovations for the products, and there will be no
prior notice when these changes happen. If there was any misunderstanding
regarding the version in a different language, please regard the Chinese
version as the right one. The final explanation right belongs to Trina Solar.
Product Specifications
Connector system | Φ4mm |
---|---|
Rated voltage | IEC 1500V&UL 1500V |
Rated current @IEC(85℃) | 41A(4.0mm2 / 12AWG) |
46A(6.0mm2 / 10AWG)
55A(10.0mm2 / 8AWG)
Rated impulse voltage| 16KV
Ambient temperature range| -40℃~+85℃
Contact resistance| ≤0.5mΩ
Application degree| Class A
Protection class| Class Ⅱ
Pollution degree| 2
Degree of Protection| IP68(1m,1h),mated
IP2X,unmated
Flame class| UL94-V0
Insulation material| m-PPE/PA
Contact material| Copper, Tin-plated
Type of termination| Crimping
Locking system(UL)| Locking type
TUV , IEC62852| R50401767/R50385924/ R50508240
UL, UL6703| E486009
Product Selection Form
3.1 TS4 PV connector
Type| P/N| Cable
OD| Conductor
Cross Section| Tool P/N
---|---|---|---|---
Wire Stripper P/N| Rivet Plier
P/N| Spanner
P/N
mm| mm2| A” ‘wG
TS4-F1| 7A000986| 4.7-6.0| 4.0/6.0| 12/10| 7A001039| 7A001038| 7A001040
TS4-M 1| 7A000987
TS4-F2| 7A000982| 5.6-6.8
TS4-M2| 7A000983
TS4-F3| 7A002404| 6.0-6.6
TS4-M3| 7A002425
TS4-F4| 7A000984| 6.0-7.2
TS4-M4| 7A000985
TS4-F5| 7A000992| 7.2-8.7| 7A001036
T54-M5| 7A000981
TS4-F6| 7A000990| 10.0| 8| 7A001037
TS4-M6| 7A000991
TS4-F7| 7A004375| 6.6-7.2| 4.0/6.0| 12/10| 7A001039| 7A001036
TS4-M7| 7A004378
TS4-F8| 7A004377| 5.6-6.6
TS4-M8| 7A004376
TS4-F9| 7A002997| 6.9-7.5| 4.0/6.0| 12/10| 7A001038
TS4-M9| 7A002996
3.2 TS4 Plus PV connector
Type | P/N | Cable OD | Conductor Cross Section | Fool P/N |
---|
Wirc Stripper
P/N| Rivet Mier P/N| Spanner P/N
mm| mm2| AWG
TS4 Plus-Fl| 7A004669| 4.7-6.0| 4.0/6. 0| 12/10| 7A0010 39| 7A001038| 7A00454
1
TS4 Plus-MI| 7A004670
TS4 Plus-F2| 7A004671| 5.6-6.8
TS4 Plus-M2| 7A004672
TS4 Plus-F3| 7A004673| 6.0-7.2
TS4 Plus-M3| 7A004674
Note 1:Select the connector specification and Part No. matched with the
cable, and ensure that the cross-sectional area of the conductor and the OD of
the cable are within the range. Otherwise, it will affect the use and create
safety risks.
Note 2:The specification of the connector with * is an O-type metal
terminal.
Connector Appearance Size Drawing
4.1 TS4 PV connector
4.1.1 Positive Connector
TS4-F1、TS4-F2、TS4-F3、TS4-F4、TS4-F9:
4.1.2 Negative Connector
TS4-M1、TS4-M2、TS4-M3 、TS4-M4、TS4-M9:
TS4-M5、TS4-M6、TS4-M7、TS4-M8:
4.2 TS4 Plus PV connector
4.2.1 Positive Connector
TS4 Plus-F1、TS4 Plus-F2、TS4 Plus-F3
4.2.2 Negative Connector
TS4 Plus-M1、TS4 Plus-M2、TS4 Plus-M3
Installation
5.1 Tools Requirements
5.1.1 Wire Stripper
P/N | Jaw | Crimping Range |
---|---|---|
7A001039 | Middle | 4.0mm2 |
Right side | 6.0mm2 | 10AWG |
7A001037 | Right side | 10.0mm2 |
5.1.2 Rivet Plier
P/N | Jaw | Riveting Range | Picture |
---|---|---|---|
7A001038 | Middle | 4.0mm2 | 12AWG |
Right side | 6.0mm2 | 10AWG | |
7A001036 | Adju stable | 4 | 4.0mm2 |
--- | --- | --- | --- |
6 | 6.0mm2 | 10AWG | |
8 | 10.0mm2 | 8AWG |
5.1.3 Plastic Unlocking Spanner
1 set =2 pc,TS4 P/N:7A001040,TS4 Plus P/N:7A004541
5.1.4 Tool Box
For TS4 Connector:
P/N| Wire Stripper| Rivet Plier| TS4 Unlocking Spanner|
Picture
---|---|---|---|---
7A001039 Qty.| 7A001037| 7A001038| 7A001036 Qty.| 7A001040 Qty.
7A001035| 1pc| None| 1pc| None| 2pcs|
7A001034| None| 1pc| None| 1pc|
7A004329| 1pc| None| None| 1pc
TS4 Plus For TS4 Plus Connector:
P/N| Wire Stripper| Rivet Plier| TS4 Plus Unlocking|
Picture
---|---|---|---|---
| | | Spanner|
---|---|---|---|---
7A001039 Qty.| 7A001037 Qty.| 7A001038 Qty.| 7A001036 Qty.| 7A004541 Qty.
7A004675| 1pc| None| 1pc| None| 2pcs|
5.2 Assembly Steps
-15~+35℃。For assembling of components, we recommend an ambient temperature between -15~+35℃.
5.2.1 Stripping
L=6±0.5mm。Strip the plastic insulating layer of cable. L=6±0.5mm.
Note: Please pay attention and do NOT cut off and damage the copper wire
core under the cable insulating plastic.
5.2.2 Inserting pin and socket
Place the metal terminal (pin or socket) in the hole of the riveting tool. The riveting hole is facing out. The most outer edge of the metal terminal is flat with the riveting interface. Refer to chapter 5.1.2 for jaw selection.
5.2.3 Crimping pin and socket
Insert the stripped cable into the rivet hole of the metal terminal, and make sure all the individual strands are in the hole. Ensure the coaxial of metal parts and cables. Finally, press the riveting tool handles all the way and press it to the end to complete the riveting. All individual strands should be crimped.
For the crimping pliers (7A001036) used for O-type metal terminals, adjust the jaw to the corresponding gear according to different specifications of cables, and adjust the height of the knob so that the outermost edge of the metal terminal is flush with the riveting interface. See Below.
Gear | Cable spec | Connector type |
---|---|---|
4 | 4.0mm2/12AWG | TS4-F5/F7/F8 |
TS4-M5/M7/M8
6| 6.0mm/10AWG
8| 10.0mm2/8AWG| TS4-F6
TS4-M6
Qualified crimping samples must meet IEC 62852 and the following criteria.
The picture below are riveted pins and sockets.
Insert the riveted metal terminal into the plastic body of the positive or negative until it engages. Gently pull the cable to check whether the metal terminals are firmly engaged. Confirm that the negative pin is coaxial with the negative body.
Note: Before inserting the cable and metal terminal into the plastic body, do NOT unscrew the nut to prevent the internal seal from falling or installing in the opposite direction.
5.2.5 Install the nut
First, screw the nut by hand, then lock it tightly by a plastic spanner.
For TS4 Connector:
Type | Cable OD range | Control gap | Reference torque |
---|---|---|---|
TS4-F1/M1 | 4.7-6.0mm | 0<X<1.0mm | 3±0.5 N*m |
TS4-F2/M2 | 5.6-6.8mm | ||
TS4-F3/M3 | 6.0-6.6mm | ||
TS4-F4/M4 | 6.0-7.2mm | ||
TS4-F5/M5 | 7.2-8.7mm | 1.0<X≤1.8mm | <5 N*m |
TS4-F6/M6
TS4-F7/M7| 6.6-7.2mm| 0<X≤1.0mm| 3±0.5 N*m
TS4-F8/M8| 5.6-6.6mm| 0<X<1.0mm
TS4-F9/M9| 6.9-7.5mm| 0<X≤1.0mm
For TS4 Plus Connector:
Type | Cable OD range | Control gap | Reference torque |
---|---|---|---|
TS4 Plus-F1/M1 | 4.7-6.0mm | 0<X<1.0mm | 3±0.5 N*m |
TS4 Plus-F2/M2 | 5.6-6.8mm | ||
TS4 Plus-F3/M4 | 6.0-7.2mm |
Refer to the following figure for the Control gap.
Note 1:Ensure the concentricity of cable and cable nut when you screw
cable nut.
Note 2:Make sure the negative pin and the negative body are coaxial and
then lock the nut.
Note 3:When the nut is locked, the clearance X value shall be strictly
controlled. When the OD of the cable deviates to the lower limit, the control
gap shall deviate to the lower limit of the control value; On the contrary, it
is biased to the upper limit of the control value.
Connecting and Disconnecting
6.1 Connecting
Plug the coupling together until they engage. And pull lightly to check
correct engagement.
6.2 Disconnecting
The negative and positive terminals of the connectors must be unlocked with the TS4 plastic spanner (part# 7A001040) or TS4 Plus plastic spanner (part# 7A004541).
Cable
7.1 Connection of Cable
In order to avoid deformation of the cable sealing element from that force generated by bending the wires, the cable should have at least a 20mm straight length nearest to the connector. See the figures below.
Note: Please refer to the detailed instructions on the minimum bend
radius specified by the cable manufacturer.
7.2 Connection Status
Trina Solar Service Point
ADD No. 2 Tian He Road, Electronics Park, New District, Changzhou, Jiangsu
213031, P. R. China
Website:www.trinasolar.com
Region | Address | Telephone Number | E-Mail Address |
---|---|---|---|
EU | Regus East Midlands Airport Pegasus Business Park Herald | +44 1332 63 | |
8799 | EUservice@trinasolar.com | ||
Way, Castle Donington Derby, DE74 2TZ – United Kingdom | |||
--- | --- | --- | --- |
Richtistrasse 11 8304
Wallisellen- Switzerland| +41 43 299 6800
Einsteinring 26 – 85609
Aschheim – Germany| +49 89 1228 49250
C/Caleruega, 79, 3º-A, 28033,
Madrid , SPAIN| +34 91 133 59 39
USA &
Canada| 100 Century Center, Suite 501
San Jose CA 95112| +1 800 696 7114|
NAservice@trinasolar.com
Japan| 21F World Trade Center Building 2-4-1 Hamamatsu-cho,
Minatu-ku, Tokyo 106-6121| +81 3 3437 7000|
Japanservice@trinasolar.co
m
Please visit the Trina Solar site for viewing, downloading, and printing these instructions at http://www.trinasolar.com
References
- Solar for Home, Utility, and Commercial | Trina Solar US
- Solar for Home, Utility, and Commercial | Trina Solar US
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>