Blood Glucose Monitoring System

The Blood Glucose Monitoring System is a device used to measure blood glucose levels in individuals with diabetes. It consists of a meter, lancet device, test strips, and a charging cable. The meter displays the blood glucose level after a test strip with a blood sample is inserted into it. The lancet device is used to prick the fingertip to obtain the blood sample.

Instructions for Use

  1. Charge the meter for at least 6 hours using the included charging cable before using it for the first time.
  2. Insert a new lancet into the lancing device and twist off its plastic cap. Adjust the cap to your desired puncture depth level.
  3. Using your thumb, push the sliding button back. You will hear a click, indicating that the lancet carrier is locked into position.
  4. Position the end of the device against the side of the fingertip. Press the trigger button to actuate the lancet.
  5. Power on the meter and insert a new test strip until it is fully seated and “Apply Blood” appears.
  6. Make sure the “Apply Blood” screen is displayed. Touch the blood drop until the end is filled. After the test strip is filled, the device will display a countdown while calculating the reading.
  7. Your test result will appear after the countdown is over. Select a Reading Tag during or after the countdown. Press the CONTINUE button to confirm your selection and send your result to the server. A response message from the server will be displayed if the results are sent successfully. Remove the test strip.
  8. To view and add logs, press the LOGS icon on the Application Menu or use the buttons to access the logs.
  9. Press the FILTER button to only view certain types of logs.
  10. Swipe Up/Down or use the buttons to scroll through stored readings and other entries.
  11. Press the ADD LOG button on the Home Screen or Logs Screen to create a new log entry.
  12. Press the EDIT button to create or delete new types of logs.
  13. Press the CREATE A LOG button to enter the value, tag, and timestamp of a log entry.
  14. Press the SUBMIT button to save and upload the new log entry to the server.

OVERVIEW

BioTel-BGM-4-QSG-ENG-SPA-Blood-Glucose-Monitoring-System-fig
1

BEFORE YOU START

Before fi rst use, charge the glucose meter for at least 6 hours with the AC charger included in your kit.
Conduct a Control Solution Test per instructions in Section D.2 of the BioTel Care® BGM User Manual.
Wash your hands and testing site with warm water and soap. Dry your hands well.
Clean and disinfect your lancing device after every use. Clean and disinfect your meter at least once a week. Please refer to details in the manual.

TAKE A BLOOD GLUCOSE TEST

  1. Insert a new lancet into the lancing device and twist off its plastic cap.BioTel-BGM-4-QSG-ENG-SPA-Blood-Glucose-Monitoring-System-fig 4
    IMPORTANT: The lancing device is intended for single patient use.

  2. Adjust the cap to your desired puncture depth level.

  3. Using your thumb, push the sliding button back.
    You will hear a click, indicating that the lancet carrier is locked into position.

  4. Position the end of the device against the side of the fingertip.
    Press the trigger button to actuate the lancet.

  5. Power on and insert a new test strip until it is fully seated and Apply Blood appears

  6. Make sure the APPLY BLOOD screen is displayed.
    Touch the blood drop until the end is filled.
    After the test strip is fi lled, the device will display a countdown while calculating the reading.

  7. BioTel-BGM-4-QSG-ENG-SPA-Blood-Glucose-Monitoring-System-fig 10

  8. The BioTel Care® BGM will automatically send the results to the server. A response message from the server will be displayed if the results are sent successfully.
    Remove the test strip.

VIEW & ADD LOGS

  1. On the Application Menu, press the LOGS icon OR use the buttons to access the logs .BioTel-BGM-4-QSG-ENG-SPA-Blood-Glucose-Monitoring-System-fig 12

TELCARE, LLC
600 West Ridge Road, Suite 200
Linwood, PA 19061, USA
Phone: 888-666-4530 (US) or (1) 978-610-4688 (International)

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals