The 2ft. LED T8 Tubes are designed to replace traditional fluorescent tubes with energy-efficient LED lighting. The retrofit kit includes the LED tube, operation instructions, and a field applied double-ended or single-ended application label. The PLTSP4M23/PLTSP4M24 PLTSP4M25 model is suitable for use with these tubes. For further information or inquiries, please visit www.pltsolutions.com
Product Usage Instructions
- Turn off the power supply to the fixture and remove the existing fluorescent tube.
- Remove the ballast cover and disconnect the ballast from the fixture.
- Install the LED tube according to the markings on the tube itself or the included label, ensuring it is firmly in place.
- Connect the wires according to the wiring diagram provided in the operation instructions.
- Replace the ballast cover and turn on the power supply to the fixture to test the LED tube.
Note: If the LED tube does not turn on after installation, turn off the power supply and check that the wires are connected correctly. If the issue persists, contact the manufacturer for further assistance.
Installation Instructions
Double & Single ended By Pass/Line Voltage
- Product Name: LED T8 Tube Series
- Product Model: T8-LED
-
Product Features:
-
UL certified
-
Single ended:
-
Full glass housing: No Aging, Yellowing, Bending.
-
Double ended:
-
-
Product Applications:
Widely used in residential buildings, offices, shopping malls, supermarkets, hospitals, assembly lines, warehouses, etc. for energy saving illumination. -
Installation Instructions:
Please completely comply with these instructions and notes, to ensure that the product is operated in a safe condition.
Safety Precautions
For your and others’ safety, please read the precaution carefully before
installation:
- Product should be installed by qualified electrician.
- Switch of the power supply before commencing work, make sure correct connection before power on.
- Suitable for use with the following emergency equipment: PRECISION LIGHTING & TRANSFORMER, INC., model PLTSP91, PLTSP92.
- Only use the control provided with or specified by these instructions to control this lamp. This lamp ill not operate properly when connected to a standard (incandescent) dimmer or dimming control. Only operate with specific dimmer manufactured by Lutron, type NTELV-300.
WARNING:
- WARNING – Risk of fire or electric shock. LED Retrofit Kit installation requires knowledge of luminaires electrical systems. It not qualified, do not attempt installation. Contact a qualified electrician.
- WARNING- Risk of fire or electric shock. Install this kit only in the luminaires that have the construction features and dimensions shown in the photographs and/or drawings and where the input rating of the retrofit kit does not exceed the input rating of the luminaire.
- WARNING1o prevent wiring damage or abrasion, do not expose wiring to edges of sheet metal or other
- WARNING: To avoid potential fire or shock hazard, do not use this retrofit kit in luminaires employing shunted bi-pin lampholders.
- Note: Shunted lamp holders are found only in fluorescent luminaires with Instant-start. ballasts. Instant-start ballasts can be identified by the words “Instant Start” or “I.S.” marked on the ballast. This designation may be in the roam of a statement pertaining to the ballast its, or made combined with the information. contact the led Luminaire retrofit it Sue 1r example reoil. For more information, contact the LED luminaire retrofit kit manufacturer.
Do not make or alter any open holes in an enclosure of wiring or electrical components during kit installation. Installers should not disconnect existing wires from lamp holder terminals to make new connections at lamp holder terminals. Instead installers should cut existing lamp holder leads away from the lamp holder and make new electrical connections to lamp holder lead wires by employing applicable connectors.
THIS RETROFIT ASSEMBLY IS ACCEPTEDAS A COMPONENT OF A LUMINAIRE WHERE THE SUITABILITY OF THE COMBINATION SHALL BE DETERMINED BY UL OR AUTHORITTES HAVING JURISDICTTON. THERE ARE TUBE, OPERATION INSTRUCTION AND THE FIELD APPLIED DOUBLE-ENDED OR SINGLE-ENDED APPLICATION LABEL IN THIS RETROFIT KIT
Type B LAMP- intended for operation in luminaires with traditional fluorescent-type lamp holders wired directly to the branch circuit. This includes both factory-wired luminaries as well as those converted for this purpose under a retrofit program.
The units covered by this report were intended to retrofit surface mount, Type IC or nonbloc recessed mount Listed fluorescent luminaires that use maximum 4 tubular lamps, the minimum lamp compartment dimensions are tabulated below
This device complies with Part 15 of the FCC Rules.
Operation is subject to the following two conditions:
- this device may not cause harmful interference, and
- this device must accept any interference received, including interference that may cause undesired operation.
The below ballast wiring represents typical configuration.
The actual ballast wiring varies according to ballast model. The socket should
be non-shunted.
Singale ended Wiring Instruction
-
Retrofit luminaire with 1 lamp
-
Retrofit luminaire with 2 lamps
-
Retrofit luminaire with 3 lamps
-
Retrofit luminaire with 4 lamps
Double ended Wiring Instruction
-
Retrofit luminaire with 1 lamp
-
Retrofit luminaire with 2 lamps
-
Retrofit luminaire with 3 lamps
-
Retrofit Luminaire with 4 lamps
Any further questions or interests, please visit www.pltsolutions.com
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>