BARTEC TYPE RCDE500L Floodlight Instructions
- June 10, 2024
- BARTEC
Table of Contents
- TYPE RCDE500L Floodlight
- INTRODUCTION
- IDENTIFICATION
- SPECIFICATION OF THE PRODUCT
- PREPARING THE PRODUCT FOR USE
- TAKING PRODUCT OUT OF OPERATION
- Documents / Resources
Instruction for use
IU15-214
Rev. 1 del 01/12/2021
FLOODLIGHT TYPE RCDE500L
Copy for: – User
(translation of official version)
TYPE RCDE500L Floodlight
INDEX AND DESCRIPTION OF MODIFIES
Nr of revision | date | description of modified |
---|---|---|
0 | 13/11/2018 | first issue |
1 | 1-12-2021 | Change of the name and address of the applicant and manufacturer |
(Bartek FN)
INTRODUCTION
Scope
This handbook has been written up from the constructor of the equipment and it
is integrating part of it.
This handbook defines the scope for which the equipment it has been designed
and manufactured and contains all the information necessary in order to
guarantee of a sure and corrected use.
The observance of the contained indications in it, guarantees the personal
emergency and one greater duration of the same equipment.
The contained information in the manual present are addressed to subject
following:
- assigned to the transport, handling, unpack;
- assigned to the preparation of installation and its site;
- installer;
- equipment’s users;
- assigned to the maintenance.
This handbook must be conserved must be conserved with the maximum care and it
be available always for eventual consultations; therefore it must be protect
from humidity, carelessness, sunlight and how much other can damage it.
For a fast search of the arguments to consult the index to the previous page.
The warnings and the important parts of text have been evidenced by means of
use of the symbols following illustrated and defined.
General warning
The producer is thought raised from every responsibility for damages caused to the system or the things in the following cases:
- improper use;
- employment of not suitable staff;
- not corrected assembly and installation;
- defects in the systems;
- modifications or interventions not authorized;
- use of non-original spare parts;
- non-observance of the rules written in this handbook;
- exceptional events.
Every operation not described in this handbook and/or not authorized by manufacturer, beyond making to lose in immediate way the guarantee, involves the full responsibility of who executes it.
Guarantee
- The guarantee is applied to the equipments that introduce defects of construction or assemblage, according to the judgment of the technicians of the house builder.
- The guarantee doesn’t cover the subject parts to usury and the due breaking to bad use and the not observance of the contained norms in this manual.
- In accord to the Directive 1999/43/CE of the European Parliament and of the Council, the duration of the guarantee is of two years from the date of delivery.
- The use of non-original exchanges BARTEC F.N. it makes to decay the guarantee.
- BARTEC F.N. won’t answer of damages or drawbacks caused by the missed observance of the contained norms in the manual present.
- The guarantee is made factory; they don’t result therefore covered the costs for the transport of the equipment in guarantee from the client to the producer and vice versa.
- The guarantee doesn’t cover the cost of the hand of necessary work to the substitution or reparation of the made piece.
- The guarantee decay in the case:
– of apparent tampering of the equipment.
– of changes brought to the equipment without previous authorization written from BARTEC F.N.
– of reparations effected from personal not authorized by BARTEC F.N.
– the number of register has been altered or cancelled or the mark BARTEC F.N. has been eliminated.
Residual risk
he equipment, even though used correctly, introduces of the residual, typical
risks of all equipment connected to the electrical net.
In case of not respect of the instructions, would be the risk of muscle-
skeletal lesions to the back.
IDENTIFICATION
Product brand and type designation
Floodlights type: RCDE500L
Producer name and address
BARTEC F.N.
via Mario Pagano 3 – I-20090 Bruzzano sulk Navigo (MI) ITALY
Tel: +39.02.484741 – Fax: +39.02.48474231
http://www.bartec-fn.com – e-mail: info@bartec-fn.com
SPECIFICATION OF THE PRODUCT
Maintenance and installation
The check and the maintenance of lighting floodlights series RCDE500L have
done in accord to the rules:
EN/IEC 60079-14 Explosive atmospheres. Part 14: Electrical installations
design, selection and erection.
EN/IEC 60079-17 Explosive atmospheres. Part 17: Electrical installations
inspection and maintenance.
General functions and range of applications, intended use
Lighting Floodlights series RCDE500L is intended for use on the surface (group
II), in areas in which, during the normal activities, explosive atmospheres
caused by gases, vapours, mists and/or air/dust mixtures are likely to occur.
Lighting fixture RCDE500L has been designed to be capable of functioning in
conformity with the operational parameters established by BARTEC F.N. and of
ensuring a high level of protection.
The type of protection adopted ensure the requisite level of protection, even
in the event of frequently occurring disturbances or equipment faults which
normally has been taken into account during risk analysis.
The technician and the user have to know the risks to the electric current and
the chemical characteristics of the gases and/or vapour, present in zone with
danger of explosion. Both must have put to knowledge of the dangers during the
installation and the maintenance.
The components or accessories installed, can be replaced, if necessary, only
with the same furnished by BARTEC F.N.
The inspection and maintenance of the equipment’s must be carried out only
from expert staff, whose training has included all the necessary instructions
on the installation modalities, on the laws and standards relevant and on the
general principles of the classification of the hazardous areas.
Electrical equipment
The electrical equipment complies with the relevant construction standards.
Type of lamps | P max [W] | V max [V] | f [Hz] |
---|---|---|---|
LEDs | 192 | 277 | 50-60 |
Technical data
Materials
Body/Cover| Aluminum-silicon primary alloy for sand-casting (EN_AC43100)
or for gravity/die casting (EN_AC44100) according to standards UNI EN1706:
2010 – ISO3522: 2007.
Quantity of magnesium (Mg), titanium (Ti) and Zirconium (Zr) is minor of 7,5%
of total mass.
---|---
Gaskets| Silicone (LSR)
Temperature: -60°C … + 260°C
Light-transmitting
part| The transparent part for safety is made of sodium calcium glass
type A, according to standards UNI EN 752.1/2, and it is sealed to the housing
through the sealant “SILICONE SARATOGA HT” Temperature: -60°C … + 260°C
Nipple sealant| Electron MC 62/W 363 Elates. Temperature: -60°C…+250°C
Ambient temperature range
-60°C ≤ Tam ≤ +60°C
Dimensions and weight Floodlights (for transport purpose)
Dimensions | Size |
---|---|
A [mm] | 432 |
ØB [mm] | 400 |
C [mm] | 441 |
ØD [mm] | 1/2″ or 3/4” |
E [mm] | 358 |
Weight [Kg] | 21 |
IP code and clear text
Degree of protection: IP66
→ First characteristic numeral – against ingress of solid foreign objects
symb. | no. | denomination | description |
---|---|---|---|
6 | persons | protected against tools and wires over 1 [mm] in diameter | |
things | dust-tight | no ingress of dust. |
→ Second characteristic numeral – against water
symb. | no. | denomination | description |
---|---|---|---|
6 | protected against | ||
powerful water jets | water projected in powerful jets against the enclosure |
from any direction shall have no harmful effects
Environmental conditions and limits for operation and storage
For the use in a consistent explosive atmosphere in a mix of air and inflammable substances in the form of gas, vapours, fogs (G), for normal atmospheric conditions they intend:
- temperature: -60 / +60 [°C] * pressure: 80 ÷ 110 [kPa] For storage conditions see following par. 4.1 “transport and storage”.
Positions and information relative to the labels
Main tag RCDE500L
1 | brand, name and address of the manufacturer |
---|---|
2 | equipment type designation given by manufacturer |
3 | specification number of customer (if request) |
4 | year of construction and serial number |
5 | ambient temperature range |
6 | nominal electrical characteristic |
7 | warning used for all types of enclosure |
8 | graphic symbol of conformity CE marking |
9 | identifying number of Notified Body responsible of production surveillance |
on “ATEX” equipment
10| distinctive community mark specific of explosion protection
11| ATEX marking (only)
II: group of apparatus – equipment suitable to be installed in surface places
2G: category – equipment suitable to be installed in places in which, during
the normal activities, explosive atmosphere caused by gases, vapours, mists
(G) are likely to occur (zone 1); suitable to be installed in zone 1 and in
zone 2.
2D: category – equipment suitable to be installed in places in which, during
the normal activities, explosive atmosphere caused by mixture of air and
combustible dust are likely to occur (zone 21); suitable to be installed in
zone 21 and in zone 22.
12| IECEx marking – type of protection
Ex: protection against explosion db: type of protection flameproof
IIC: equipment suitable to be installed in surface places for all types of
combustible gas
Gb: equipment for explosive gas atmospheres, having a “high” level of
protection, which is not a source of ignition in normal operation or during
expected malfunctions
tb: protection by enclosures, (for EPL Db)
IIIC: for use in places with an explosive dust atmosphere other than mines
susceptible to firedamp; conductive dust
Db: equipment for explosive dust atmospheres, having a ”high” level of
protection, which is not a source of ignition in normal operation or during
expected malfunctions IP66 dust-tight (6); protected against powerful water
jets (6)
13| Identification of Notified Body that have issued the EC-type examination
certificate and its relative number (see declaration of conformity)
14| Identification of Notified Body that have issued the IECEx certificate of
conformity and its relative number
PREPARING THE PRODUCT FOR USE
Transport and storage
Lighting Floodlights series RCDE500L is furnished in:
- pack of carton
- wood boxes
- wood cages
Is the boxes in wood that the cages in wood, they are in accord to the standard ISPM15 of the FAO.
In case of storage, the pack has been protected:
| from rain
---|---
| from impact
| from sunlight
| from humidity
| put in vertical position
Storing of floodlights series RCDE500L must respect the following conditions:
| ambient temperature: from -20 [°C] a +60 [°C];
---|---
| to avoid the superimposition of more packs
Handling
For handling there aren’t request of particular demands to assigned staff, therefore it is recommended, to carry out such operation observing the common rules of accident prevention.
Safety precautions before use
In the event of installation in places where the formation of stray electric currents can be present (i.e.: outskirts of electrical railway networks, great systems of welding, electrical systems with high currents and radio frequencies, etc.), it is right to take adequate precautions to avoid consequences. How general rule, whichever intervention on the electrical or mechanical parts or on the system, must be preceded from the interruption of the electrical supply system.
Unpacking
It is opportune to eliminate, immediately, the parts of pack that could be dangerous to the persons (nail, tapes, plastic bags, etc.).
- To make sure that pack have not suffered external damages during the transport.
- Place down the right side of the pack and unpacked the electrical pump.
- Extract the equipment from pack him through the fittest way in relation to the weight of the same equipment.
Safety disposing of packaging material
All pack materials are recyclable and they can dispose according to law in force.
| carton
---|---
| wood
Notes
Spread anti-seize paste, electro-conductive, high and low temperature, on the
threaded joint after every removal of cover type L0358 of CFG s.r.l. or
equivalent.
The user, will have to check at least once the year the good state of the
gasket and in case of usury, replace with analogous product furnished by
BARTEC F.N. For the use in presence of a potentially atmosphere explosive
caused by dusts, the user will have to effect a to regulate cleaning of the
for eliminate the deposits of dust. The maximum quantity of dust will have to
be inferior to the 5mm. The width of the flameproof joints is superior to the
value specified in table 3 and 4 of IEC/EN 60079-1.
TAKING PRODUCT OUT OF OPERATION
Scraping
It is recommended to address to specialized companies authorized for the scraping, according to laws and standards in force.
The present document is property of BARTEC F.N.
Its copyright in any format, whole or partial, must be before authorized by
BARTEC F.N.
IU15-214_ r1
Documents / Resources
|
BARTEC TYPE RCDE500L
Floodlight
[pdf] Instructions
TYPE RCDE500L Floodlight, TYPE RCDE500L, RCDE500L Floodlight, Floodlight
---|---
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>