AcerAltos City850 UPS Line-interactive UPS User Manual

June 9, 2024
AcerAltos

AcerAltos City850 UPS Line-interactive UPS User Manual

AcerAltos City850 UPS Line-interactive UPS User Manual

IMPORTANT SAFETY INSTRUCTIONS

(SAVE THESE INSTRUCTIONS) This manual contains important safety instructions. Please read and follow all instructions carefully during installation and operation of the unit. Read this manual thoroughly before attempting to unpack, install, or operate your UPS. CAUTION! To prevent the risk of fire or electric shock, install in a temperature and humidity controlled indoor area free of conductive contaminants. (See the specifications for the acceptable temperature and humidity range.)
CAUTION! To reduce the risk of overheating the UPS, do not cover the UPS’ cooling vents and avoid exposing the unit to direct sunlight or installing the unit near heat emitting appliances such as space heaters or furnaces.
CAUTION! Do not attach non-computer-related items, such as medical equipment, life-support equipment, microwave ovens, or vacuum cleaners to UPS.
CAUTION! Do not plug the UPS input into its own output.
CAUTION! Do not allow liquids or any foreign object to enter the UPS. Do not place beverages or any other liquid-containing vessels on or near the unit.
CAUTION! In the event of an emergency, press the OFF button and disconnect the power cord from the AC power supply to properly disable the UPS.
CAUTION! Do not attach a power strip or surge suppressor to the UPS.
CAUTION! Unplug the UPS prior to cleaning and do not use liquid or spray detergent.
CAUTION! Servicing of batteries should be performed or supervised by personnel knowledgeable of batteries and the required precautions. Keep unauthorized personnel away from batteries.
CAUTION! The battery supply should be therefore disconnected in the plus and minus pole at the quick connectors of the battery when maintenance or service work inside the UPS is necessary.
CAUTION! Internal battery voltage is 12Vdc. Sealed, lead-acid, 6-cell battery.
CAUTION! When replacing the batteries, use the same number and type of batteries.
CAUTION! Do not dispose of batteries in a fire. The battery may explode. Do not open or mutilate the battery or batteries. Released electrolyte is harmful to the skin and eyes.

INSTALLING YOUR UPS SYSTEM

UNPACKING The box should contain the following: (1) UPS Unit x1; (2) USB Cable x 1 (Except City650); (3) User Manual 1; (4) Warranty Card 1

OVERVIEW The UPS provides automatic voltage regulation for inconsistent utility power, and provides battery backup during power outages, and ensures consistent power to your computer system.

HARDWARE INSTALLATION GUIDE

  1. Your new UPS may be used immediately upon receipt. However, recharging the battery for at least 8 hours is recommended to ensure that the battery’s maximum charge capacity is achieved. Charge loss may occur during shipping and storage. To recharge the battery, simply leave the unit plugged into an AC outlet. The unit will charge in both the on and off position.
  2. With the UPS unit off and unplugged, connect the computer, monitor, and any externally powered data storage device (Zip drive, Jazz drive, Tape drive), etc. into the battery power supplied outlets. DO NOT plug a laser printer, copier, space heater, vacuum, paper shredder or other large electrical device into the battery power supplied outlets. The power demands of these devices will overload and possibly damage the unit.
  3. Plug the UPS into a 2 pole, 3 wire grounded receptacle (wall outlet). Make sure the wall branch outlet is protected by a fuse or circuit breaker and does not service equipment with large electrical demands (e.g. air conditioner, refrigerator, copier, etc. Avoid using extension cords.
  4. Press the power switch to turn the unit on. The power on indicator light will illuminate and the unit will “beep”.
  5. If an overload is detected, an audible alarm will sound and the unit will emit one long beep. To correct this, turn the UPS off and unplug at least one piece of equipment from the battery power supplied outlets. Wait 10 seconds. Make sure the circuit breaker / fuse is normal and then turns the UPS on.
  6. To maintain optimal battery charge, leave the UPS plugged into an AC outlet at all times. 7. To store your UPS for an extended period, cover it and store with the battery fully charged. Recharge the battery every three months to ensure battery life.

BASIC OPERATION

Front panel

  1. Power Switch
    Press the switch for 2 seconds to turn the UPS ON or OFF. Mute setting: The audible alarm can be turned OFF or ON by quickly pressing the power button twice. The default setting is for the Alarm On.

  2. Line Mode LED The green LED will light when utility power is normal.

  3. Battery Mode LED The yellow LED will light when input power is abnormal and the unit will work in battery mode.

  4. Fault LED The red LED will light when fault or over load occurs.

Rear panel

  1. USB COMM. Port
    This port allows connection and communication from the USB port on the computer to the UPS unit.

  2. RJ45/11 Communication Protection Ports
    Communication protection ports will protect any standard modem, fax, telephone line, or network cable

  3. Input Circuit Breaker
    The circuit breaker provides optimal overload protection.

  4. Input power cord
    Connect to utility power.

  5. Battery Backup & Surge Protected Outlets
    Provide battery backup and surge protection. They ensure power is provided to connected equipment over a period of time during a power failure.

TECHNICAL SPECIFICATIONS

AcerAltos City850 UPS Line-interactive UPS User Manual - TECHNICAL
SPECIFICATIONS AcerAltos City850 UPS Line-interactive UPS User Manual - TECHNICAL
SPECIFICATIONS

DEFINITIONS FOR LED & ALARM

AcerAltos City850 UPS Line-interactive UPS User Manual - DEFINITIONS FOR LED
& ALARM

TROUBLE SHOOTING

AcerAltos City850 UPS Line-interactive UPS User Manual - TROUBLE
SHOOTING

SOFTWARE DOWNLOAD

Power Master Management software provides a user-friendly interface for your power systems. The graphic user interface is intuitive and displays essential power information at a glance. Please follow procedure below to install the software.
Installation procedure:

  1. Download Power Master from the website: http://www.powermonitor.software/#PowerMasterSoftware 
  2. Double-click the file and follow the installation steps.
    When your computer restarts, the Power Master software will appear as a blue icon located in the system tray.

AcerAltos City850 UPS Line-interactive UPS User Manual - Installation
procedure

In a continuing effort to improve the quality of our products, information in this document is subject to change without notice. Please refer Altos support website (www.altoscomputing.com) for latest information. Responsible Party: Altos Computing Incorporated Address: 6F, No.88, Section 1, Xintai 5th Road, New Taipei City 221, Taiwan (R.O.C.) © 2020. All rights reserved. Altos, Acer Altos and the Altos logo are registered trademarks of Altos Computing, Inc. Other trademarks, registered trademarks and/or service marks, indicated or otherwise the properties of their respective owners.

About Altos
Altos Computing Inc. (abbr. Altos) is established in 2017 and it is a subsidiary of Acer Inc. The business model of Altos is to provide the best streamlined and cost-effective integrated solutions thru in-house R&D working with ODM/IHV/ISV on servers, workstations, thin client, network, storage and UPS. In the era of demanding speed, Altos provides leading solution included, but not limited to High Performance Computing, Virtual Desktop Infrastructure, Cloud Infrastructure and Software Defined Storage, etc. Altos provides solutions and services to government, academia, cloud service providers, datacentre operators and enterprises.