hoymiles HMS-2000DW-4T Series Microinverters Installation Guide

June 9, 2024
hoymiles

hoymiles HMS-2000DW-4T Series Microinverters

hoymiles-HMS-2000DW-4T-Series-Microinverters-product

Product Information:

The HMS-2000DW-4T Series is a microinverter designed to convert the direct current (DC) power generated by solar panels into alternating current (AC) power. The microinverter is suitable for use with HMS-1600DW/1800DW/2000DW-4T microinverters and comes with the accessories listed below:

  • A – AC Trunk Cable, 12/10 AWG Cable
  • B – M8 x 25 screws (Prepared by the installer)
  • C – Grounding Accessory
  • D – AC Trunk Connector
  • E – AC Trunk End Cap
  • F – AC Trunk Port Disconnect Tool
  • G – AC Trunk Connector Unlock Tool
  • H – AC Trunk Port Cap

Note : All accessories above are not included in the package and should be purchased separately.

Accessories

hoymiles-HMS-2000DW-4T-Series-Microinverters-fig-
\(1\)

Note: All accessories above are not included in the package and should be purchased separately.
Applicable to HMS-1600DW/1800DW/2000DW-4T microinverters

Product Usage Instructions

Follow the steps below to install and use the HMS-2000DW-4T Series microinverter:
The order of Step 1 and Step 2 can be reversed according to your planned needs

Step 1: Plan and Install the Microinverter

  1. Mark the position of each microinverter on the rail, according to the PV module layout.
  2. Fix the screw on the rail.hoymiles-HMS-2000DW-4T-Series-Microinverters-fig- \(2\)
  3. Hang the microinverter (label side up) on the screws and beneath the PV module. Then tighten the screws.

Note:hoymiles-HMS-2000DW-4T-Series-Microinverters-fig-
\(3\)

  • There is an earth wire inside the wire cable and the grounding can be done directly by this wire. If external grounding is needed, the grounding accessories, as shown on the right, can be used to bond the mounting bracket to the racking. Torque each grounding cleat screw to 2 N•m.
  • Install the microinverter and all DC connections beneath the PV module to avoid direct sunlight, rain exposure, snow buildup, UV, etc.
  • Leave at least 2 cm of space around the microinverter enclosure to ensure ventilation and heat dissipation.
  • Mounting torque of the 8 mm screws should be 9 N·m.Please do not over-torque.
  • Do not pull or hold the AC cable with your hand. Hold the handle instead

Step 2: Plan and Build the AC Trunk Cable

The AC Trunk Cable is used to connect the microinverter to the distribution box. Follow the steps below to build the AC Trunk Cable:

  1. Select the appropriate AC Trunk Cable according to the spacing between microinverters. The connector spacing of the AC Trunk Cable should be close to spacing between microinverters to ensure that they are well-matched. (Hoymiles provides AC Trunk Cable with different AC Trunk Connector spacing.)
  2. Determine how many microinverters you plan to install on eachAC branch and prepare AC Trunk Connectors accordingly.
  3. Take out segments of AC Trunk Cable as you need to make AC branch.
  4. Disassemble the AC Trunk Connector and remove the cable.
  * Use the AC Trunk Connector Unlock Tool to unlock the connector upper cover.![hoymiles-HMS-2000DW-4T-Series-Microinverters-fig- \(4\)](https://manuals.plus/wp-content/uploads/2023/03/hoymiles-HMS-2000DW-4T-Series-Microinverters-fig-4.png)
  * Loosen the three screws with screwdriver. Untighten the cap and remove the cable.![hoymiles-HMS-2000DW-4T-Series-Microinverters-fig- \(5\)](https://manuals.plus/wp-content/uploads/2023/03/hoymiles-HMS-2000DW-4T-Series-Microinverters-fig-5.png)
2. Install the AC Trunk End Cap at one side of AC Trunk Cable (The end of AC Trunk Cable).
  * Insert the AC Trunk End cap and screw the cap back to port, then tighten the cap.![hoymiles-HMS-2000DW-4T-Series-Microinverters-fig- \(6\)](https://manuals.plus/wp-content/uploads/2023/03/hoymiles-HMS-2000DW-4T-Series-Microinverters-fig-6.png)
  * Plug the upper cover back to the Trunk connector.![hoymiles-HMS-2000DW-4T-Series-Microinverters-fig- \(7\)](https://manuals.plus/wp-content/uploads/2023/03/hoymiles-HMS-2000DW-4T-Series-Microinverters-fig-7.png)
3. Install AC end cable on the other side of AC Trunk Cable (connected to the distribution box).
  * Unlock the port upper cover, loosen the screws with screwdriver and remove the extra cable. (Skip this step if there is no cable at this side.)![hoymiles-HMS-2000DW-4T-Series-Microinverters-fig- \(8\)](https://manuals.plus/wp-content/uploads/2023/03/hoymiles-HMS-2000DW-4T-Series-Microinverters-fig-8.png)
  * Prepare a segment of AC cable with suitable length to connect to the distribution box, with stripping requirements fulfilled.![hoymiles-HMS-2000DW-4T-Series-Microinverters-fig- \(9\)](https://manuals.plus/wp-content/uploads/2023/03/hoymiles-HMS-2000DW-4T-Series-Microinverters-fig-9.png)
  * Insert the cable into the cap in a way that the L, N and PE lines are in corresponding slots.![hoymiles-HMS-2000DW-4T-Series-Microinverters-fig- \(10\)](https://manuals.plus/wp-content/uploads/2023/03/hoymiles-HMS-2000DW-4T-Series-Microinverters-fig-10.png)
  * Tighten the screws and tighten the cap back to the port.![hoymiles-HMS-2000DW-4T-Series-Microinverters-fig- \(11\)](https://manuals.plus/wp-content/uploads/2023/03/hoymiles-HMS-2000DW-4T-Series-Microinverters-fig-11.png)
  * Plug the upper cover back to the Trunk connector.![hoymiles-HMS-2000DW-4T-Series-Microinverters-fig- \(12\)](https://manuals.plus/wp-content/uploads/2023/03/hoymiles-HMS-2000DW-4T-Series-Microinverters-fig-12.png)
  1. Repeat the above steps, lay out the cable on the rail as appropriate so that the microinverters can be connected to the Trunk connectors.
  2. Attach the AC Trunk Cable to the mounting rail and fix the cable with tie wraps.hoymiles-HMS-2000DW-4T-Series-Microinverters-fig- \(13\)

Step 3: Complete the AC Connection

Follow the steps below to complete the AC Connection:

  1. Push the AC Sub Connector from microinverter to the AC Trunk Connector until it clicks.
  2. Connect the AC end cable to the distribution box, and wire it to the local grid network.
  3. Please plug the AC Trunk Port Cap in any vacant AC Trunk Port to make it water and dust-proof.hoymiles-HMS-2000DW-4T-Series-Microinverters-fig- \(16\)

Note :
Make sure that the AC Trunk Connectors are kept away from any water-channeling surface.
In case you need to remove the inverter AC cable from AC Trunk Connector, please use the AC Trunk Port Disconnect Tool and insert the tool into the side of AC Sub Connector to complete the removal.hoymiles-HMS-2000DW-4T-Series-
Microinverters-fig- \(17\)

Step 4. Create an Installation Map

  • A ) Peel the removable Wi-Fi Module Serial Number Label from each microinverter.
  • B ) Affix the serial number label to the respective location on the installation map (please refer to the User Manual)hoymiles-HMS-2000DW-4T-Series-Microinverters-fig- \(18\)

Step 5. Connect PV Modules

  • A ) Mount the PV modules above the microinverter.
  • B ) Connect the PV modules’ DC cables to the DC input side of the microinverterhoymiles-HMS-2000DW-4T-Series-Microinverters-fig- \(19\)

Step 6. Energize the System

  • A ) Turn on the AC breaker for the branch circuit.
  • B) Turn on the main AC breaker for the house. Your system will start to generate power in about two minutes

Step 7. Set up Monitoring System

  • A) Scan the QR code to download the S-Miles Installer application
  • B) Connect the microinverter to the the network using S-Miles Installer application.

Open the S-Miles Installer App on smartphone/tablet and login as Installer. Tap O&M icon on the bottom of the page, then tap Network Config button. This takes you to the network configuration screen On WLAN setting, select the microinverter’s hotspot and tap
Connect button. (The network name of the microinverter consists of DTUBI and product serial number, and the default password is 12345678.)hoymiles-HMS-
2000DW-4T-Series-Microinverters-fig- \(21\)

Note : If you already have an installer account, just type your account number and password to log in, otherwise, please ask your installer or distributor to create an account for you.

Set up with the Internethoymiles-HMS-2000DW-4T-Series-Microinverters-fig-
\(22\)

  • When the connection is successful, turn to the O&M screen and tap Network Config icon.
  • On the Network Config screen, tap the dropdown icon and a Wi-Fi network list will pop up.
  • Select the router Wi-Fi from the list and enter the password.
  • Tap the Send to DTU button
  • The network configuration takes about 1 minute, please be patient.
  • If there is a faulty Wi-Fi connection, please check the internet as instructed.hoymiles-HMS-2000DW-4T-Series-Microinverters-fig- \(23\)
  • Check the indicator light of the microinverter. A Solid green light means a successful connection.
    Note : If your configuration page is inconsistent with the above, please update the microinverter firmware to the latest version.

Please refer to the S-Miles Cloud Operating Guide to set up monitoring system.
Product information is subject to change without notice. (Please download reference guides at www.hoymiles.com).
Region : Global AP040779 REV1.1 © 2023 Hoymiles Power Electronics Inc.

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals