METCAL MFR-1300 Series MFR System User Guide

June 9, 2024
METCAL

METCAL-LOGO

METCAL MFR-1300 Series MFR System

METCAL-MFR-1300-Series-MFR-System-PRODUCT

MFR-1300 SERIES User Guide

Product Information

The MFR-1300 SERIES is a desoldering system that offers superior EOS (Electrical Overstress) protection. The system includes a power unit, hand- piece, workstand, and disposable collection chamber cartridge. The system is designed for use in a well-ventilated area and should only be used as described in the manual. The system should only be repaired with genuine MFR replacement parts.

Features

Contents and Identification

METCAL-MFR-1300-Series-MFR-System-FIG-1

  • Power LED
  • AC Power Switch
  • Channel LED
  • Oxide Removal Pad
  • Vacuum Port & Filter
  • Channel Switch
  • Output Connector
  • Sulfur-free Sponge
  • Disposable Collection Chamber Cartridge MFR-DC10

Maintenance

To change the coil assembly, remove the screws and replace it with part number MFR-HDCA. Replace the front seal (part number AC-SK1) if it is worn. Regularly check the instrument cord and incorporate it into standard operator maintenance procedures.

Product Usage

Preparing to use the unit & Operation

METCAL-MFR-1300-Series-MFR-System-FIG-2

  1. Connect the hand-piece to the power unit output connector(s).
  2. Connect the hand-piece vacuum line to the port on the main unit.
  3. Insert your selected tip (cartridge) into the hand-piece. Push the tip (cartridge) all the way until it seats (See instructions supplied with each hand-piece).
  4. Place hand-piece(s) into associated workstand(s).
  5. Add distilled water to the workstand sponge (sulfur-free).
  6. Select the desired channel using the selector switch.
  7. Plug the power cord into a grounded wall socket of the rated input line voltage.
  8. To turn the unit on, push the AC power switch. The AC power LED should light up green.

Initial Setup & Operation

  1. Connect hand-piece to power unit output connector(s).
  2. Connect hand-piece vacuum line to the port on the main unit.
  3. Insert your selected tip (cartridge) into the hand-piece. Push the tip (cartridge) all the way until it seats (See instructions supplied with each hand-piece).
  4. Place hand-piece(s) into associated workstand(s)
  5. Add distilled water to workstand sponge (sulfur free).
  6. Select the desired channel using the selector switch.
  7. Plug the power cord into a grounded wall socket of the rated input line voltage.
  8. To turn the unit on, push the AC power switch. The AC power LED should light up green.

METCAL-MFR-1300-Series-MFR-System-FIG-3

Using the Desolder Tool

Always use the tip removal pad for changing tips. To use the desolder tool, follow the instructions supplied with each hand-piece. Depress the latch to unplug the handle. Plug into the left port of the main unit, next to the vacuum port, until the latch locks in place.

Disposable Collection Chamber Cartridge MFR-DC10

To replace filters, slide the collection chamber back until the latch locks, then remove it. Connect the vacuum line to the vacuum port on the main unit.

Tip Selection
Select the appropriate tip (cartridge) for your application. Refer to the table below for part numbers and dimensions.

Part Number Regular Long Reach
DFP-CN2 0.64 mm (Dimension A) 2.0 mm (Dimension B)
DFP-CN3 0.76 mm (Dimension A) 2.3 mm (Dimension B)
DFP-CN4 1.02 mm (Dimension A) 2.6 mm (Dimension B)
DFP-CN5 1.27 mm (Dimension A) N/A
DFP-CN6 1.52 mm (Dimension A) 2.8 mm (Dimension B)
DFP-CN7 2.41 mm (Dimension A) 3.6 mm (Dimension B)
DFP-CNL3 N/A 2.0 mm (Dimension B)
DFP-CNL4 N/A 2.3 mm (Dimension B)
DFP-CNL5 N/A 2.6 mm (Dimension B)

METCAL-MFR-1300-Series-MFR-System-FIG-4

Waste Electrical and Electronic Equipment Directive – WEEE (2002/96/EC)
When this product is no longer required, if it cannot be re-used, do not dispose of it as unsorted municipal waste but appropriately recycle the product. In Europe, please contact your OK International distributor who can advise the recycling options available (www.metcal.com).

WARNING
With power applied, the tip temperature can be > 300°C. Failure to observe the following precautions may lead to injury to users or damage the equipment:

  • Do not touch any metallic parts of the hand-piece
  • Do not use near flammable items
  • Do not use unit for any function other than described in this manual
  • Use only genuine MFR replacement parts
  • Use in a well ventilated area
  • Do not use the equipment with wet hands
  • Connect only to properly grounded outlets to prevent risk of electric shock.
  • Always place hand-piece back into the workstand to prevent accidental burning of oneself or surrounding objects.

Although the systems offer superior EOS (Electrical Overstress) protection, periodic checks of the instrument cord should be incorporated into standard operator maintenance procedures.

Maintenance of Desolder Tool
To change coil assembly remove screws (Fig. 1), replace with part number MFR- HDCA. Replace front seal part number AC-SK1 if worn. Disposable Collection Chamber Cartridge MFR-DC10 (package of 10) MFR-DC100 (package of 100)

Replacing the Vacuum Port Filter on the MFR-PS1300

  1. a. Turn the filter cover anti-clockwise until it stops then pull to remove.
  2. b. Remove old filter (use tweezers). Insert new filter, (AC-VPF.)
  3. c. Reinstall filter cover, push and then turn clockwise to lock.

METCAL-MFR-1300-Series-MFR-System-FIG-5Use part number MFR-DC10 for replacement chamber cartridge, flux filter and in-line fume filter. To ensure good vacuum check all filters, hoses, coil assembly seal and desolder cartridge for blockages.

LED Indications and Meaning

METCAL-MFR-1300-Series-MFR-System-FIG-6

Auto-Sleep and Auto Off Functions
To prolong tip life, MFR systems with a soldering hand-piece (MFR-H1-SC2, MFR-H2-ST2) include an “Auto-Sleep Workstand” (WS1). When the hand-piece is placed into the workstand, the “Auto-Sleep Workstand” immediately reduces power to the hand-piece. All MFR systems have an “Auto Off” Function. The “Auto Off” Function will be engaged when the hand-piece has been idle in the sleep stand for a period of two hours. The channel LED indicator light will go from green to Off. The “Auto Off” Function can be reset by cycling the power switch.

SmartHeat® & Calibration
SmartHeat® technology establishes and retains heater idle temperature by virtue of Curie effect inside the heater core. This phenomenon occurs at the atomic level and consequently idle temperature cannot shift over time nor can it be altered by the operator. Accordingly the system requires absolutely no calibration. Contact us at support@okinternational.com

Specifications

  • Ambient Operating Temperature 10 – 40°C (50 – 104°F)
  • Maximum Enclosure Temperature 55°C (131°F)
  • Input Line Voltage 100- 240 VAC, grounded circuit
  • Input Line Frequency 50/60 Hz
  • Power Consumption 110 Watts max. (MFR-PS1300)
  • Output Power 60 Watts max. at 22°C (71°F) ambient temperature
  • Output Frequency 450 kHz
  • Power Cord 3-Wire 183cm (72”) (18/3) SJT
  • Dimensions w x d x h 170mm (7”) x 200mm (8”) x 152.5mm (6”)
  • Certification / Marking cTUVus, CE
  • Tip-to-Ground Potential <2mV
  • Tip-to-Ground Resistance <2 ohms
  • Idle Temperature Stability ± 1.1°C (34°F) in still air
  • Desolder Hand-piece Cable Length L=152cm (60”), burn proof, ESD safe
  • Other Hand-piece Cable Length L=122cm (48”), burn proof, ESD safe
  • Hand-piece Connector 8-pin circular DIN
  • Workstand Dimensions w x d x h 100 mm (4”) x 200 mm (8”) x 100 mm (4”)

Warranty

Please visit OK International’s web page (www.metcal.com) where you will find available information on systems, accessories, technical notes, and more. OK International warrants the MFR-PS1300 against any defects in materials or workmanship for one (1) year from the date of purchase by the original owner. This Warranty excludes normal maintenance and shall not apply to any opened, misused, abused, altered or damaged items. If the product should become defective within the warranty period, OK International will repair or replace it free of charge at its sole option. The repaired or replacement item will be shipped, freight prepaid, to the original purchaser. The warranty period will start from the date of purchase. If the date of purchase cannot be substantiated the date of manufacture will be used as the start of the warranty period. The MFR-H5-DS hand-piece uses a coil assembly which is a consumable item. OK International warrants the coil assembly against material and workmanship defects for a period of 30 days. For contact details for Warranty and Support look for your local office details at: www.metcal.com

SPARE PARTS:

  • AC-PM1 Pump with Motor Replacement Kit
  • AC-PR1 Pump Rebuild Kit

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>