Operation

  1. Plug the mains plug into the socket.
  2. Switch the device on with the ON/OFF switch.

Note
Pump starts immediately. Wait until the pump sucks in and delivers evenly, then close the stop valves in the pressure line.
After reaching the switch-off pressure, the pressure switch switches off the motor. The storage tank is now filled, the domestic water supply is ready for operation.
If there is no water supply, the switch-off pressure is not reached and the pressure switch can no longer shut off the device. This heats up the water in the pump head.
To prevent damage to the pump due to overheating, the power supply is interrupted by the thermal switch in the event of overheating. After cooling down, the power supply is restored.
Note
The cooling time until the engine restarts can be up to 150 minutes.
We recommend the use of a dry-running protection device (see special accessories) for regular protection against water shortage.
ATTENTION
Risk of injury, the system is pressurised!
When opening a pressurised system, you can be injured by flying parts.
Depressurise the device before opening the connections (for pressure, see chapter Technical data)

Ending operation

  1. Switch off the device at the ON/OFF switch.
  2. Unplug the device at the mains plug.
    Care and maintenance

DANGER

Danger of electric shock.
Always switch the device off and disconnect the mains plug before working on the device.
The device is maintenance-free.

Pressure relief

  1. Open and close connected stop valves for pressure relief.
    The system is depressurised.

Note
Rinse the pump with clear water after each use when pumping water with additives.

Check the pressure of the air filling in the storage tank

  1. Check the pressure of the air filling in the storage tank every six months, if necessary top up to 2.0 bar when the device is switched off/depressurised (unplug the device,
    open the water tap)

Note
The type plate is located below the cover. Unscrew the cover in an anti- clockwise direction.
Illustration B

Transport

CAUTION
Risk of injury
Risk of injury from falling device.
When transporting the device, observe the weight of the device (see chapter Specifications) and secure it accordingly when transporting it in vehicles.

Storage
CAUTION
Failure to observe the weight
Risk of injury and damage
Be aware of the weight of the device during storage.

  1. Empty the device completely before storage.
  2. Store the device in a frost-protected place.

Special accessories
You will find the possible special accessories on the last page of these operating instructions.
Troubleshooting guide
Malfunctions often have simple causes that you can remedy yourself using the following overview. When in doubt, or in the case of malfunctions not mentioned here, please contact your authorised Customer Service.

Fault Cause Rectification
Pump is running, but not delivering There is air in the pump. 1. See

chapter Preparation
The air cannot escape on the pressure side.| 1. Open the tapping point on the pressure
side.
No water available.| 1. Check the water reservoir.
The pump does not start up, or stops suddenly during operation| The power supply is disconnected.| 1. Check the fuses and the electrical connec-
tions.
Thermal protection switch in the motor has switched off the pump due to over- heating of the motor.| 1.Pull out the mains plug.
2.Allow the pump to cool down.
3.Clean the suction area.
4.Prevent dry running.
Note
The cooling time until the motor starts can be up to 150 minutes.
The pump switches itself off and also on again| The thermal protection fuse has switched off the pump to protect it from overheat- ing or switched it on again after it has cooled down.| 1. To prevent recurrence, the system should
be checked for leaks and sealed.
The motor restarts imme-
diately after switching off| The pressure in the system is lost.| 1. Check the connections including seals and
check for water leakage. The slightest leakage affects operation.
The air pressure in the storage tank is too low.| 1. Fill the storage tank with 2.0 bar (see chap-
ter Care and maintenance).
The return valve does not close properly.| 1. Check the check valve on the suction side.
The membrane in the pressure tank is defective.| 1. Have the membrane replaced.
The pump capacity drops or is too low| The suction filter or the check valve (spe- cial accessory) are contaminated.| 1. Clean the suction filter or the check valve
(special accessory).
The delivery rate of the pump depends on the delivery head and the connected periphery.| 1. Observe the max. delivery head (see chap-
ter Specifications) Select a different hose diameter or a different hose length if necessary.
Vibrating noise during water removal| The membrane in the pressure tank vi- brates.| 1. An operating noise that can be eliminated
by reducing the pressure of the air filling in the storage tank.

Specifications

| | BP 3.200 Home| BP 4.900 Home
---|---|---|---
Mains voltage| V| 230-240| 230-240
Power frequency| Hz| 50| 50
Nominal power| W| 600| 1150
Device performance data
Maximum flow rate| I/h| 3200| 4900
Suction height (max.)| m| 8| 8
Pressure (max.)| MPa (bar)| 3,6| 5,0
Max. pressure of the air filling in the storage tank| MPa (bar)| 0.18 – 0.2 (1.8 – 2.0)| 0.18 – 0.2 (1.8 – 2.0)
Max. permissible inner pressure in the storage tank| MPa (bar)| 0.50 (5.0)| 0.50 (5.0)
Delivery height (max.)| m| 28| 35
Dimensions and weights
Weight (without accessories)| kg| 10,5| 13,9

Note
Reason for exception according to regulation (EU) 2019/1781 Annex I Section 2 (12): (j) Subject to technical modifications!

Characteristic curves

KARCHER BP 3.200 Home Irrigation Pumps -
CharacteristicKARCHER BP 3.200 Home
Irrigation Pumps - Characteristic1

Declaration of Conformity

EU Declaration of Conformity
We hereby declare that the machine described below complies with the relevant basic safety and health requirements in the EU Directives, both in its basic design and construction as well as in the version placed in circulation by us.
This declaration is invalidated by any changes made to the machine that are not approved by us.
Product:
Pump Type:
1.645-xxx
Currently applicable EU Directives
2014/35/EU
2014/30/EU
2011/65/EU
2009/125/EC
Commission Regulation(s)
(EU) 2019/1781
Harmonised standards used
EN 60335-1
EN 60335-2-41
EN 62233: 2008
EN 55014-1: 2017 + A11: 2020
EN 55014-2: 1997+A1: 2001+A2: 2008
EN 61000-3-2: 2014
EN 61000-3-3: 2013
EN IEC 63000: 2018
The signatories act on behalf of and with the authority of the company management.

KARCHER BP 3.200 Home Irrigation Pumps - signeture

Documentation supervisor:
S. Reiser
Alfred Kärcher SE & Co. KG
Alfred-Kärcher-Str. 28 – 40
71364 Winnenden (Germany)
Ph.: +49 7195 14-0
Fax: +49 7195 14-2212
Winnenden, 2021/06/01

Declaration of Conformity (UK)
We hereby declare that the product described below complies with the relevant provisions of the following UK Regulations, both in its basic design and construction as well as in the version put into circulation by us.
This declaration shall cease to be valid if the product is modified without our prior approval.
Product: Pump
Type: 1.645-xxx
Currently applicable UK Regulations
S.I. 2016/1101 (as amended)
S.I. 2016/1091 (as amended)
S.I. 2012/3032 (as amended)
S.I. 2010/2617 (as amended)
Commission Regulation(s)
(EU) 2019/1781
Designated standards used
EN 60335-1
EN 60335-2-41
EN 62233: 2008
EN 55014-1: 2017 + A11: 2020
EN 55014-2: 1997+A1: 2001+A2: 2008
EN 61000-3-2: 2014
EN 61000-3-3: 2013
EN IEC 63000: 2018
The signatories act on behalf of and with the authority of the company management.

KARCHER BP 3.200 Home Irrigation Pumps - signeture

Documentation supervisor:
S. Reiser
Alfred Kärcher SE & Co. KG
Alfred-Kärcher-Str. 28 – 40
71364 Winnenden (Germany)
Ph.: +49 7195 14-0
Fax: +49 7195 14-2212
Winnenden, 2021/06/01

 OPTIONAL SPECIAL ACCESSORY

KARCHER BP 3.200 Home Irrigation Pumps - fig 3

THANK YOU!
MERCI! DANKE! iGRACIAS!

Register your product and benefit from many advantages.
www.kaercher.com/welcome
  Rate your product and tell us your opinion.

KARCHER BP 3.200 Home Irrigation Pumps - icon 6www.kaercher.com/dealersearch
Alfred Kärcher SE & Co. KG
Alfred-Kärcher-Str. 28-40
71364 Winnenden (Germany)
Tel.: +49 7195 14-0
Fax: +49 7195 14-2212KARCHER BP 3.200 Home Irrigation Pumps -
qrhttp://kaer.ch/er/?l=TwSoJtl9IUOwZyAe1rHDyw

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals