katranji LCDA257S Closed – Loop Stepper Driver User Manual

June 9, 2024
katranji

LCDA257S Closed – Loop Stepper Driver
User’s Manual

Installation

  1. Electrical indicators
    Voltage input range : DC:20~50V (Recommended 36V or more)
    Maximum output current:6A
    Pulse form: pulse + direction, CW / CCW
    Logic input current:10~20mA
    Impulse response frequency:0~200KHZ
    Insulation resistance:500M

  2. Environmental indicators
    Save the temperature:-20C°~80C°
    Operating temperature:0C°~55C°
    Use humidity:90%RH(No condensation)
    Vibration frequency: Less than0.5G(4.9m/s?)10HZ~60HZ(Non-continuous operation)

  3. Installation dimensions(unit mm)

Drive terminal description

Power terminal definition

Serial number symbol Functional definition
1 A+

Motor power line terminal wiring color See motor on the label

2| A—
3| B+
4| B-
5| +VDC| DC power input terminal recommended DC 36V or more
6| GND

Drive control terminal definition

Pin symbol Description
1 PUL+ Pulse input positive
2 PUL- Pulse input negative
3 DIR+ Direction input positive
4 DIR- Direction input negative
5 ENA+ Enable input positive
Pin symbol Description
--- --- ---
6 ENA- Enable input negative
7 ALM+ Alarm output positive
8 ALM- Alarm output negative

Drive encoder terminal definition

P i n symbol Colour Description
1 EB+ yellow Encoder B signal is positive
2 EB- green Encoder B signal is negative
3 EA+ black Encoder A signal is positive
4 EA- blue Encoder A signal is negative
5 VCC red Encoder + 5V input
6 EGND white Encoder power ground

Drive communication terminal definition

pin symbol Remarks
1 NC No definition
2 GND Signal ground
3 TXD RS232 Sending end
4 RXD RS232 Receiving end
5 GND Signal ground
6 +5V Power is positive

Drive and computer communication line connection

Control port wiring

Pic 2 Common anode wiring method Pic 3 Common cathode wiring method

Pic 4 Differential signal input and output signal connection

Note: When the control signal voltage VCC = 24V, the current limiting resistor R = 3K;
When the control signal voltage VCC = 5V, the current limiting resistor R = 0;

Control signal timing diagram

Note: Hold time delay Brake delay time
Three, DIP switch setting

This series of drive current for the automatic tuning, so do not need to manually set the current, DIP switch corresponding functions are as follows:
Set the drive subdivision (see details on the driver
SW1~SW4 : are shell subdivision table)
SW5 ;: Set the motor direction
SW6 : Current self-tuning mode switch
SW7 : Working mode selection
SWS : Pulse input form selection
SW9 : Pulse edge selection

Four. Parameter settings

Common parameters are shown in the table below:

Parameter number| Parameter Description| Predetermined area|
---|---|---|---
PA_002| Position loop low speed P| 1~32767|
PA_003| Position loop high speed P| 1~32767|
PA_004| Sped loop low speed P| 1~32767|
PA_005| Speed loop high speed P| 1~32767|
PA_006| Set the number of pulses per revolution| 200~ 32767|
PA_008| Position error limit| 10~32767|
PA_013| Rated current percentage| 1~100|
PA_015| Input filter switch| 0~1|
PA_016| Input filter time| 0~ 32767|
PA_017| Enable level selection| 0~1|
PA_018| Faulty state selection| 0~1|
PA 020| Pulse mode selection| 0~65536|
PA_021| Restore factory parameters| 0~1|
PA_028| Percentage of open loop torque| 0~ 100|
PA_029| Speed loop denounce time| 0~65536|
PA_030| Speed loop integral| 1~100|