VIXEN HORNS VXT3000AB 3 Gallon 6 Ports Train-Horn Aluminum Air Tank Installation Guide
- June 9, 2024
- VIXEN HORNS
Table of Contents
VXT3000AB
INSTALLATION GUIDE
BEFORE BEGINNING YOUR INSTALLATION
Read through the instruction guide before getting started with the installation. Professional installation is recommended for this product.
CONTENTS
- 3 Gallon Aluminum Air Tank (Black)
- Mounting Hardware
Over pressuring the tank beyond the specified maximum working pressure (200 PSI) may result in death or serious injury.
SAFETY INSTRUCTIONS
-
Install all fittings and accessories in the tank before pressurizing the tank.
-
Before assembly, use thread sealant on all fitting’s threads, then use a wrench to tighten each part.
IMPORTANT: Do not over tighten. -
Tank must be drain frequently.
-
We recommend always to install a drain and safety valves in the tank.
-
Always depressurize the tank before servicing or adding accessories.
-
Do not use this tank as a breathing device.
-
Be sure to pump nothing other than atmospheric air.
-
It is important to determine the maximum air pressure for any tool or attachment before using it.
-
Make sure your battery ground is detached before you begin the installation.
-
Employ equipment for eye protection during drilling operations.
PLANNING YOUR INSTALLATION
- Before beginning the installation, determine each component’s spot.
- Confirm you have the proper length of airline and wire.
MOUNTING
- Find a convenient mounting location in your vehicle for the air tank. Ensure ports are reachable before drilling any holes.
- Mark the location of holes using the mounting bracket of the air tank as a template, and then drill to size.
- Using mounting hardware, secure the air tank.
IMPORTANT: Do not mount on a flexible material.
BRAIDED HOSE INSTALLATION
- Connect the stainless steel braided hose of your compressor to the tank’s inlet port.
PORT LOCATIONS AND THREAD SIZE (NPT)
MAINTENANCE
- Make sure that electrical and fitting connections are regularly inspected, cleaned and tightened when needed.
- Make sure mounting screws are regularly tightened if needed.
- Drain weekly, to avoid excessive buildup of condensation.
SOLUTIONS TO COMMON ISSUES
Issue: Loss of pressure of tank.
Solution 1: Tighten drain cock.
Solution 2: Examine air and check valves and replace if damaged or leaking.
Solution 3: Use soap and water solution on air connections and tank, and
tighten connections or repair leaks where needed.
Issue: Air horn is inaudible
Solution 1: Check all switches to make sure they are ON.
Solution 2: Assure air tank is pressurized.
Solution 3: Check the fuse; if blown, disconnect compressor from power and
replace the fuse.
Solution 4: Examine electrical connection for damage or corrosion, secure
electrical connections.
Issue: Excessive moisture in horn or safety valve (if installed).
Solution 1: Depressurize and drain the tank.
Solution 2: Relocate the compressor to a drier location.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>