autopilot APC8200 CO2 Monitor and Controller with Remote Sensor User Manual

June 9, 2024
autopilot

autopilot - logo APC8200 CO2 Monitor and Controller with Remote Sensor
User Manualautopilot APC8200 CO2 Monitor and Controller with Remote
Sensor The Best Grow (Pty) Ltd / orders@thebestgrow.co.za
Tel: 076 808 8526

OVERVIEW

Thank you for purchasing the Autopilot CO2 Monitor & Controller with Remote Sensor! Our products are packaged and shipped with the utmost care. In the unlikely event  that your item is incorrect, incomplete, or unsatisfactory, please contact us and we will resolve the issue.

WARNINGS

  • To ensure safe operation, please read this manual carefully before installation and follow the instructions.
  • Store this manual in a secure place for future reference.
  • WARNING: CHOKING HAZARD – Accessories contain small parts.

FEATURES AT A GLANCE

  • CO2 controller; Tracer (Data logger)
  • Built-in Day/Night sensor
  • Chart with variable time Zoom Levels
  • 2-Channel Low Drift NDIR Sensor
  • “Hold Home” function
  • MIN/MAX display at the click of a button

OPERATING INSTRUCTIONS

Initial Setup: When first unboxing, plug the piggyback into the power socket. If successfully connected, 3 things will happen while booting up:

  1. Alarm will beep once.
  2. Chart display will show the current software version & “Warm Up”.
  3. Main display will show a countdown from 10.
    autopilot APC8200 CO2 Monitor and Controller with Remote Sensor -
countdown

LCD DISPLAY

autopilot APC8200 CO2 Monitor and Controller with Remote Sensor -
DISPLAY

  1. CO2 Trend Chart
  2. AVG HI reading of Chart
  3. AVG LO reading of Chart
  4. Audible Alarm On/Off
  5. CO2 Zone value (deadband setting)
  6. CO2 Center value (Ideal CO₂ level)
  7. CO2 Reading
  8. Zoom Level of Time –  indicates the chart’s timespan
  9. Target Zone Indicator

Once the countdown is complete, your product is ready to use. No additional setup or calibration is needed.
CO2, SET CENTER, SET ZONE READINGS
The device has three built-in main parameters: ambient carbon dioxide (7), Set Center value (6), and Set Zone value (5). They are constantly displayed on screen.

TREND CHART ZOOM
Below is a table showing the available Zoom Levels for all CO2 parameters, as well as the duration of each interval for corresponding Zoom Levels:
The DOWN button will toggle the available Zoom Levels for each parameter. Note that in addition to the Zoom Levels for each parameter, there is an option that will  automatically cycle between the Zoom Levels. This can be achieved by pressing DOWN until icon (8) appears at the bottom left of the chart.

Zoom Level (Time Span) (8)  Span) (8) Time Per Interval
1m (minute) 5sec /div
1h (hour) 5m/div
1d (day) 2h/div
1w (week) 0.5d/div
Auto Cycle Zoom Cycle

AVG HI/AVG LO
At the top right corner of the display, there are two numerical indicators: AVG HI (2) and AVG LO (3). As the Zoom Level is changed, the AVG 1-11 and AVG LO will reflect the average high and average low values on the chart of the selected parameter. At startup, the unit will automatically display values for id (day) value.

AUTO DETECT DAY/NIGHT
The built-in photocell sensor can automatically detect whether it is Day or Night. It can override the CO2 control and shut off the CO2 generator or regulator by turning off the output power during the night. Conversely, if the Photo-Cell detects light and the CO2 level is low, the device will start the CO2 generator by turning on output power.

CO2 OUTPUT CONTROL
Output power is on when the CO2 concentration is below Set Center+(1/2) Set zone, and off when CO2 concentration is over Set Center-(1/2) Set zone. For example, if the Set Center is 1200 ppm, and the Set zone is 400ppm, the output power will shut off when CO2 over 1200+(1/2)(400)=1400 ppm, and power on when CO2 below 1200-(1/2)(400)=1000 ppm. In other words, if you want a ±100 ppm deadband you should enter 200ppm here. That means the unit will allow a 100 ppm swing above or below your Set Center CO2 Setting.autopilot APC8200 CO2
Monitor and Controller with Remote Sensor - CONTROL

HOLD HOME
To revert to start-up settings at any point, hold ENTER for 3 seconds until you hear audible beep. The device will then revert to Home Setting, as if the power was reset,  displaying “Back Home done.” Note that this is not the same as Restore to factory settings.
To clear all stored data in the chart you must Restore to factory settings. To use Restore mode select the Advanced Setting function and hold ENTER for 3 seconds until an  audible beep sounds.
Below is a table showing what main menu selection is made by pressing MENU multiple times as well as their functions. Note that the device will display “Done,” followed  by the confirmed selection if selected correctly.

MAX/MIN
From the home screen, press ENTER. The trend chart will be replaced by “MAX,” and the maximum value will be shown in the main display area. Press ENTER again to  view the minimum value. Press ENTER once again to return to the home screen.
Note that after 10 seconds if ENTER is not pressed, the device will return to the home screen.

LED DISPLAY

MAIN MENU FUNCTIONS
The Main Menu functions can be toggled through by selecting the MENU button. If the main menu is not selected, the menu LED will remain off, leaving the UP buttons to toggle Zoom Levels, respectively.

autopilot APC8200 CO2 Monitor and Controller with Remote Sensor -
LED

  • S1 Set Center (Custom CO2 ppm setting)
  • S2 Set Zone (Deadband)
  • S3 Home
  • S4 Re-Calibrate
  • S5 Advance Setting

Pressing MENU once will bring up the menu LED, with flashing before the current choice.
To select the function, press ENTER when menu selection LED is flashing. Note that after 1 minute if nothing is pressed, the Main Menu LED will shut off and the device  will revert to the normal state.

FUNCTION

Si Set Center

| DIRECTIONS
---|---
Set Center value is preset to 1200 ppm. Once Set Center is selected (by pressing ENTER), use either UP or DOWN to increase or decrease the Set Center value. Press ENTER one more time to confirm.
52 Set Zone
(Deadband)| This function allows the user to set the Zone (Deadband). Once selected, Use UP and DOWN to increase or decrease the set zone value. Press ENTER to confirm. Note that the default value of set zone is 400 ppm. See CO2 OUTPUT CONTROL for setting a custom deadband.
53 Home| This is for basic indoor gardening, and cannot be adjusted. Once selected, the Set Center value is fixed 1200 ppm, and Set Zone value is fixed 400 ppm.
54 Re-Calibrate| Use this function to calibrate your device with outside atmospheric CO2 level — 400 ppm. Select this mode, hold ENTER for 3 seconds until a beep and the chart will read “Calibrating”, then place the device outside for 20 minutes. To escape, press MENU. Make sure the device is far from a source of CO2, not in direct sunlight, and not exposed to water. Step away from the unit during calibration.
55 Advance Setting| This function toggles between 3 things when selected:
• Audible Alarm On/Off
• Altitude Setting
• Restore Factory Setting
Restore Factory Setting will reset the device to factory settings and erase all stored data in the chart. To use Restore mode, hold ENTER for 3 seconds until an audible beep.

SPECIFICATIONS

Typical test conditions, unless otherwise specified: Ambient Temp =73+/-3°F (22 +/-3°C), RH=50%–70%, Altitude=0~100 meter

MEASUREMENT SPECIFICATION
Operating Temperature 32°F to 122°F (0°C to 50°C)
Storage Temperature -4°F to 140°F (-20°C to 60°C)
Operating & Storage RH 0-95%, non-condensing

CO2 Measurement

Accuracy at 0-1000 ppm| ±50 ppm or ±5% of reading, whichever is greater
Accuracy over 3000 ppm| ±7%
Repeatability| 20 ppm at 400 ppm (standard dev. of 10 readings in 1 minute)
Measurement Range| 0-5000 ppm
Display Resolution| 1 ppm (0-1000); 5 ppm (1000-2000); 10 ppm (>2000)
Temp Dependence| 1-0.2% of reading per °C or ±2ppm per °C, whichever is greater, referenced to 25 C
Pressure Dependence| 0.13% of reading per mmHg (corrected by user’s altitude input)
Response Time| <2 min for 63% of step change or <4.6 min for 90% step change
Warm-up Time| <30 sec
Power input| AC 100 a’ 240 VAC
Dimensions| Sensor Unit: 153 x 33 x 27 mm (6.0″ x 1.3″ x 1.1″) Control Unit: 195 x 145 x 44 mm (7.7″ x 5.7″ x 1.7″)
Weight| 700 g (24.7 oz)

DISCLAIMERS
This device is not intended for workplace hazard CO2 monitoring, nor intended as a definitive monitor for human or animal health institutions, life sustenance, or any  medical-related situation.
Hydrofarm and the manufacturer assume no responsibility for any damage or loss suffered by the user or any third party arising through the use of this product or its  malfunction.
Hydrofarm reserves the right to change the specifications without notice.

LIMITED WARRANTY

Hydrofarm warrants the APC8200 to be free from defects in materials and workmanship. The warranty term is for 3 years beginning on the date of purchase. Misuse, abuse,  or failure to follow instructions is not covered under this warranty. Hydrofarm’s warranty liability extends only to the replacement cost of the product. Hydrofarm will not be  liable for any consequential, indirect, or incidental damages of any kind, including lost revenues, lost profits, or other losses in connection with the product. Some states do  not allow limitation on how long an implied warranty lasts or the exclusion of incidental or consequential damages, so the above limitations or exclusions may not apply to  you. Hydrofarm will, at our discretion, repair or replace the APC8200 covered under this warranty if it is returned to the original place of purchase. To request warranty  service, please return the APC8200, with original sales receipt and original packaging, to your place of purchase. The purchase date is based on your original sales receipt.