babcopark Pit Parking Lift System User Manual
- June 9, 2024
- babcopark
Table of Contents
babcopark Pit Parking Lift System User Manual
Pit Parking Lift
The pit parking system offers maximized installation dimension flexibility for
2 or 4 cars. The system offers great flexibility for access and comfort. The
lift provides independent access to each car through the utilization of a pit.
The ease of operation makes it ideal solutions for Developers, multi-family
projects and hotel parking.
- Independent access to each vehicle
- Ideal solution for low ceiling height parking
- Offers solid corrugated platform
- Offers multiple dimensions and customization flexibility
General Parts
- Post
- Connection Rod
- Platform
- Cylinder
- Anti-Falling Lock
- Oil Hose
FEATURES
- TUV compliant, which is the most authoritative certification in the world Certification standard 2006/42/EC and EN14010
- Low Usage Cost When the platform moves down, it is driven by gravity, so there is no electricity consumption for the pump motor
- New & improved hydraulic system The hydraulic system adopts a German top-level structure design which is stable and reliable with twice the lifetime as older models
- Newly designed control system User-friendly operation with a 50% reduced failure rate
- Galvanized, corrugated panels Long-lasting, durable, anti-slip corrugated deck
- Zero accident security system All new upgraded security system to ensure no accidents
- Dynamic locking device Mechanical locks in the front of platform for safety
- CSA-Approve power unit Meets electrical Canadian standard
- Multiple Chain Protection Devices Loose chain detection as well as break protection ensures safety
- Metallic powder coated surface After applying AkzoNobel powder the colour saturation, weather resistance and adhesion are significantly enhanced
- Rich, vibrant colour Great care is taken with the treatment of lacquer in order to improve the quality of the product surface
- Strong adhesion The weather resistance of the spray powder has better performance and can withstand wear and tear
- Superior chains 20% longer lifespan than that of domestic chains
- Laser cutting + robotic welding Accurate laser cutting improves accuracy of parts and automated robotic welding makes the weld joints stronger
- Hydraulic Centralized Control Perfect shared power unit solution
- Galvanized screw bolts Longer life screws with a much higher corrosion resistance
SPECIFICATIONS
General
Safety Devices
- b Mechanical Anti-Falling Safety Lock
- b Loosen Chain Detection System
- b Full Direction Guiding System
- b Auto Locking System In Case Of Electrical Failure
- b Emergency Stop Button
- b Pressure Relief Valve & Pressure Control Valve
- b Limit Switch Ensures Automatic Stop At Top
- b Overload Protection Device
- b Synchronization Shaft
Dimensions
Pit Parking Lift
-
Yellow & Black Safety Markings
3.9in. (100mm) wide, along the pit edge. (see page 4) Static calculations and construction work requirements -
In Case of Intermediate Walls
5.9in. (150mm) x 5.9in. (150mm) opening for electric & hydraulic system cables and pipes
• After installation, do not close the opening -
Recommended Drainage
3.9in. (100mm) x .78in. (20mm) with a 19.6in. (500mm) x 19.6in. (500mm) x 7.8in. (200mm) drainage pit
• In case of installation of a sump pump, it is necessary to comply with the drainage pit dimensions specified by the pump manufacturer -
Channels or Undercuts / Concrete Haunches
Should channels or undercuts be necessary, the system width needs to be reduced or the pit must be wider
• Not allowed along the pit floor-to-wall joints -
196.8in. (5000mm) Vehicle Length 208.6in. (5300mm) Pit Length
-
6 Free Spaces for any Connection
Performed By The Customer · Please ask Babcopark for dimension sheets -
Lintel
Notes:
- All dimensions specified are the minimum, finished dimensions
- Tolerances must be taken into consideration
- All dimensions are given in inches & millimetres
Height Dimensions
Pit Parking Lift
- With an increase in headroom available, correspondingly taller vehicles will be able to park on the upper platform.
- UL – Upper Level / LL = Lower Level
Width Dimensions
Platform Widths
90.5in. (2300mm), 181.1in. (4600mm) (Double Units): For 80.7in. (2050mm) vehicle width (without outside mirror)
94.4in. (2300mm) – 98.4in. (2500mm) (Single Units) 185in. (4700mm) – 196.8 (5000mm) For vehicles wider than 80.7in. (2050mm) (without outside mirror) For units with intermediate walls For units at the end of the driving aisle
For comfortable parking, entry and exit platform widths of 90.5in. (2300mm) are recommended. Reduced platform width means reduced parking depending on the vehicle width, type, driving style and access area of the garage.
Installation Requirements
Construction Requirements:
Fixing the Frames to the Floor Slab:
- Using base plates (approx. 602.3in.2 (15300mm2)
- Using adhesive anchor bolts M20 with 9.8in. (250mm) length
- Hole depth is more than 9.8in. (250mm)
- Concrete thickness of at least 11.8in. (300mm)
Concrete Quality Grade:
- Compliant of static requirements of construction
- Min. C30 grade (for dowel fastening)
Walls:
- Front drive-in wall and rear wall in concrete
- Perfectly flat wall surfaces
- Without protruding sections such as border edging pipes and tubes etc.
Frame Bearing Points:
- The specified lengths are expressed as mean value
Extra Space for Hydraulic Power Packs
Hydraulic Power Pack Placement Options:
- Located behind the parking lift
- Where this is not possible, it is necessary to arrange for an extra space above drive-in level (i.e. for a wall recess or a niche)
Installation Requirements
Electrical Specifications:
Cabling Preparation to be Performed by the Customer:
- Up to the main switch to be in place prior to starting the installation operations
- Connection to the main switch during installation
- Check system functionality performed by an electrician provided by the customer
Grounding and Potential Equalization:
- To be performed by the customer compliant to local regulations
Connections are Required Every 10 Meters
To Be Performed By The Customer:
Important Note:
- For garages with doors, the door manufacturer must be consulted before the electrical feed cabling is laid.
Notes & Directions
Scope of Application: Suitable for residential buildings, office
buildings and business premises such as hotels. Only for long-term users that
have been instructed on how to use the system.
For frequently changing users (e.g. for office, hotel and business premises or
similar):
- Only park on top platform
- Performance of any technical system adjustments when necessary
- Consult with Babcopark is mandatory
Noise Protection:
- Insulation figure of the construction of min. Rw = 57 dB
- Walls which are bordering the parking systems must be done as single wall and deflection resistant with min m = 300kg / m2
- Solid ceiling above the parking systems with min. m = 400 kg / m2
At differing constructional conditions additional sound absorbing measures are to be provided by the customer. The best results are achieved by separated sole plates from the construction.
Increased noise protection: If increased noise protection must be provided, planning must be confirmed on a project basis by Babcopark.
Temperature:
- System operating range: -10 to +40C (with unloading platforms lowering speed is reduced if less than +5C)
- Humidity: 50% at +40C
- In the event of changes to system conditions please consult with Babcopark
Drainage:
-
In the winter, up to 40 litres of melting snow can come from vehicles in just one parking process Recommended Drainage Channels:
-
Along the front end sections of the pit
-
Connecting to a floor drain or drainage (500 x 500 x 200 mm)
-
With manual emptying out of the drainage pit
-
Alternatively the installation of a pump or drainage channel into the sewer system can be performed by the customer
Environmental Safety: -
Coating of the pit floor is recommended
-
Installation of an oil and or gas separator unit between the drainage connection and the main sewage system is recommended
Railings:
Railings mandatory:
-
When exceeding the permissible country -specific construction gaps and opening
Safety fences mandatory: -
When walkways running alongside or behind parking lifts and / or systems positioned along border walls
-
Safety fences according to ISO 13857 to be performed by the customer (also should be completed during the construction phase)
Surface Protection:
- Please consider using surface protection
Lighting
- Sufficient lighting must be provided by the customer
Maintenance:
- Babcopark provide can provide installation and maintenance
- Regular, annual maintenance is provided subject to the stipulation of a maintenance agreement
Fire Safety:
- All the safety requirements and all mandatory equipment (fire extinguisher and fire alarm system, etc.) must be performed by the customer
Protection against corrosion:
- All operations listed in the Babcopark Cleaning and Maintenance Instructions are to be performed regularly (independently of maintenance operation)
- Zinc-plated parts, components and platforms are to be kept clean of dirt, road-salt and any other debris (due to corrosion hazards)
- Always keep the garage well ventilated and aerated
Construction Modifications
- The right to construction or model modifications and / or variations is hereby reserved
- The right to any subsequent part modification and / or variation and amendments in procedures and standards due to technical and engineering progress or due to environmental regulation changes is also hereby reserved
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>