Gamewell 600 Series Commercial Power Fire Alarms
Description
The Gamewell-FCI, IdentiFlex 602 (IF602) is ideally suited for small- to medium-sized installations of commercial, institutional, and industrial life- safety applications. The IF602 offers all the features of today’s most advanced life safety systems. The integration of analog and addressable hardwired circuits allows System Engineers to customize panels and maximize efficiency for a given application. The IF602 can monitor and control up to 252 intelligent analog addressable input/output points. The interactive operator’s display uses LED prompting for ease of programming and user operation. An alphanumeric display and keypad simplify field programming, or download programming from a Windows®-based application. The IF602’s housing was designed to be both aesthetically pleasing and functionally sound. The cabinet is designed to fit between studs for semi-flush mounting. This compact design and the key-activated dead-front construction enables secure routine maintenance of the system. Access to system function keys is limited by a key switch. Multiple levels of password protection prohibit unauthorized use. The circuit boards are mounted on a removable chassis, and are designed with pluggable terminal strips for ease of installation and service.
Operator’s Display
The IF602’s operator’s display is the source of all user access to the system.
The display provides all of the necessary keys and annunciation points to
maintain and monitor the system. Alarm, supervisory, and trouble conditions
are all indicated on the operator’s display by dedicated LEDs and an internal
sounder. The Acknowledge, Reset, and Signal Silence keys are located directly
below the 4 x 40-character backlit alphanumeric display. All system functions
and operational logic can be programmed directly from the front panel in the
field. The IF602 display includes four user-programmable function keys.
Features
- Listed per ANSI/UL® 864, 9th Edition
- One or two Signaling Line Circuits (SLC), up to 252 points.
- Apollo XP-95 protocol
- Polarity-insensitive SLC circuit wiring
- SmartStart™ self-programming logic
- Downloadable or front-panel programmable
- Password protected
- Approved for Supervisory Service
- Fully digital SLC protocol
- SmartLink™ peer-to-peer networking
- 1000-event history log
- Automatic drift compensation
- Coded signaling capability
- Adjustable sensor sensitivity and temperature settings
- Style 6, 7 (Class A) or Style 4 (Class B) SLC
- Four Style Y (Class B), or two Style Z (Class A) notification appliance circuits (NACs)
- Semi-flush mounting (between 16″ studs)
- 160-character display
- Optional GW-UDACT compatible
- Built-in strobe and horn synchronization
Analog Addressable Signaling Line Circuits
- The IF602 Analog Interface Module provides Signaling Line Circuits (SLC), loop circuits that can monitor and control up to 126 analog/addressable devices on each powerlimited loop, for a total of 252 analog points in a dual-loop system. Loop wiring is not polarity sensitive.
- Each SLC loop has a dedicated microprocessor that simultaneously communicates with connected field devices and the main CPU.
- The IF602 uses the advanced XP95 fully digital communications protocol to improve the speed and accuracy of event reporting. The communications protocol provides for alarm verification per detector, detector adjustability and compensation, adjustable analog heat detector range (131°F to 194°F, 55°C to 90°C), circuit isolation, and priority interrupts. Priority interrupts allow contact-type devices such as manual fire alarm stations to interrupt the polling cycle and transmit their addresses at any time during a polling sequence.
- The fully digital protocol allows the IF602 to operate on most types of field wiring, greatly expanding its use in retrofit applications. Consult Gamewell-FCI Technical Support for specific wiring requirements.
IF602 Power Supply
The IF602 power supply is a fully regulated 8 amp supply that furnishes system operating and signaling power. It is equipped with a battery charger which maintains the secondary power source. The power supply is monitored by the main CPU, ensuring that adequate power levels are available. The power supply design allows for high efficiency while providing precise power output. The battery charger maintains batteries up to 26 AH. The supply powers four on- board NACs (two Class A) with built-in synchronization protocols for System Sensor, Cooper-Wheelock and other brands.
I/O Devices
Addressable control output devices are the interface between analog circuits
and building functions. The outputs are controlled by Control By Event (CBE)
software within the IF602, and can be programmed to respond to any event. The
control devices can also be used as supervised remote signaling circuits.
The IF602, with Gamewell-FCI’s complete line of 600 Series devices, provides a
foundation for the system design. The IF602’s RS-232 output expands system
monitoring and control capabilities.
Remote Display and Control
Add serial annunciators to display system activity and control. Serial
annunciator drivers are available in 16-point increments and are an ideal
interface to graphic annunciators. Switches can be used for Acknowledge,
Reset, Signal Silence, Drill, etc., to customize the remote status control
network. An alphanumeric display can also be used for remote status and
control. The alphanumeric display is designed to communicate over the serial
communications network. The IF602 can communicate locally or remotely with a
printer to document system activity. See the RAN/SAN data sheets (CS-2025 and
CS-2027) for complete annunciator details.
Applications
The IF602 Analog Addressable Control Panel is designed for new or retrofit small- to mid-sized projects that require state-of-the-art life-safety systems. The embedded CPU offers users unrivaled reliability without sacrificing flexibility or value. With its compatible analog sensors and addressable input and control interface devices, and its remote status and control capabilities, the IF602 provides system engineers with all the tools necessary to design effective system solutions for any application.
Architectural/Engineering Specifications
The control panel furnished and installed shall be capable of supporting 252
addressable devices and two analog loops. The panel shall utilize a fully
digital Signaling Line Circuit (SLC) protocol. The panel shall contain four
onboard Notification Appliance Circuits (NACs) that support multiple
synchronization protocols. The panel shall use a 160-character Liquid Crystal
Display (LCD) and a 1,000- event history log. The panel shall be a Gamewell-
FCI IF602.
Specifications
- Common Control:
- Standby Current: 0.160A
- Alarm Current: 0.222 mA plus signaling circuit power, plus 0.002A for master box, or plus 0.022A for reverse-polarity
- Input Power: 120 VAC, 4.0A; or 240 VAC, 2.0A
- Auxiliary Output:
- S+/S–, A+/A–, 2.0 A maximum
- Common Relays: 1.0 A @ 30 VDC or 0.5A @ 250 VAC
- Notification Appliance Circuits:
- Circuits: Four Class B, two Class A
- Output: 3.0A maximum@24 VDC per circuit. Maximum 7.5A total for all circuits
- Analog SLC: IF602/126 IF602/252
- Standby Current: 0.045A 0.055A
- Alarm Current: 0.045A 0.055A
- Panel Dimensions:
- Standard Cabinet: 20.0″ H x 14.0″ W x 4.5″ D (50.8 H x 35.6 W x 11.4 D cm
- Battery storage dimensions:
- Standard Cabinet: 6.0″ H x 9.0″ W x 4.5″ D (15.24 H x 22.86 W x 11.43 D cm)
- Relative Humidity: 93% non-condensing Temperature
- Rating: 32°F – 120°F (0°C – 49°C)
Ordering Information
Specifications are for information only, are not intended for installation
purposes, and are subject to change without notice. No responsibility is
assumed by Gamewell-FCI for their use.
©2009 Honeywell International Inc. All rights reserved. www.gamewell-