ATLONA AT-OME-EX-TX Omega 4K-UHD HDMI Over HDBaseT Transmitter with USB Installation Guide

June 9, 2024
ATLONA

ATLONA AT-OME-EX-TX Omega 4K-UHD HDMI Over HD Base T Transmitter with USB Installation Guide
ATLONA AT-OME-EX-TX Omega 4K-UHD HDMI Over HDBaseT Transmitter with
USB

The Atlona AT-OME-EX-TX is an HDBaseT transmitter for video up to 4K/60 4:2:0, plus embedded audio, control, Ethernet, and USB over distances up to 330 feet(100 meters). Part of the Omega™ Series of integration products for modern AV communications and collaboration, the OME-EX-TX is HDCP 2.2 compliant and transmits IR, RS-232, and IP control signals. With a matching HD Base T receiver, the integrated USB extension is ideal for software video conferencing and the use of touch or interactive displays. The OME-EX-TX includes a USB host for a PC, plus two peripheral devices such as a speakerphone, microphone, or keyboard and mouse. This transmitter is ideal for use with Omega Series receivers as well as switchers with HD Base T  inputs. Also available is the OME-EX-KIT which includes the OME-EX-TX and OME-EX-RX.*

Package Contents

  • 1 x AT-OME-EX-TX
  • 1 x Captive screw connectors, 4-pin
  • 2 x Mounting plates
  • 4 x Mounting screws
  • 1 x Installation Guide

IMPORTANT: Visit http://www.atlona.com/product/AT-OME-EX-TX for the latest firmware updates and User Manual.

  • The AT-OME-EX-TX is not compatible with the AT-UHD-HDVS-300 system for extending USB.

Package Contents

  1. LAN
    Connect a category cable from this port to a network switch. This cable provide IP passthrough transport control from a control system to the display (sink) device connected to the receiver.

  2. DEVICE
    Connect up to two USB devices (e.g. mouse, keyboard, etc.) to these ports. These ports provide 2.5 W per USB device interface.

  3. HOST
    Connect a USB cable from this port to the host computer.

  4. FW
    Connect a mini USB-to-USB cable from this port, to a computer, to update the firmware. Refer to Updating the Firmware (page 10) for more information.

  5. PWR / LINK
    The PWR LED indicator will glow green when the AT-OME-EX-TX is powered. The AT-OMEEX-RX supplies power to the AT-OME EX-TX over HDBaseT. The LINK LED indicator glows yellow when a solid link is established between the transmitter and receiver. Refer to LED Indicators (page 5) for more information. 6 RS-232 / IR Connect the included 4-pin captive screw block to this receptacle. Refer to RS-232 and IR (page 3) for more information.

  6. HD Base T OUT
    Connect a category cable from this port to the HDBaseT IN port of the AT-OME- EX-RX or other PoE-compatible receiver.

  7. HDMI IN
    Connect an HDMI cable from this port to the source device.

RS-232 and IR

The AT-OME-EX-TX provides pass-through transport of RS-232 protocol and/or IR over HDBaseT, which allows communication between a control system and an RS-232 or IR device. This step is optional.

NOTE: Typical DB9 connectors use pin 2 for TX, pin 3 for RX, and pin 5 for ground. On some devices functions of pins 2 and 3 are reversed. Note that the signal (S) pin for the IR is labeled as “TX” on the port.
Instruction

Installation

  1. Connect a UHD/HD source to the HDMI IN port.
  2. Connect a USB cable from the host computer to the HOST port.
  3. Connect up to two USB devices (speakerphone, etc.) to the DEVICE ports. These ports provide 2.5 W per USB device interface.
  4.  Connect a category cable, from the HD Base T OUT port on the transmitter, to the HD Base T IN port on the receiver.
  5. OPTIONAL: Connect an Ethernet cable from the LAN port to a network switch. This cable provide IP pass-through transport control from a control system to the display (sink) device connected to the receiver.
  6. OPTIONAL: Connect an RS-232 cable between a control system and the RS-232 port on the transmitter. Refer to RS-232 and IR (page 3) for more information.
  7. OPTIONAL: Connect an IR emitter to the IR port. Refer to RS-232 and IR (page 3) for more information.

Cable Recommendation Guidelines

Refer to the tables below for recommended cabling when using Altona products with HD Base T . The green bars indicate the signal quality when using each type of cable. Higher-quality signals are represented by more bars.

Core Shielding CAT5e CAT6 CAT6a CAT7
Solid UTP (unshielded) ![Icon](https://manuals.plus/wp-
content/uploads/2023/03/Screenshot_6-166.png) N/A
STP (shielded)

IMPORTANT: Stranded or patch cables are not recommended due to performance issues.

Cable Max. Distance @ 4K Max. Distance @ 1080p
CAT5e 295 feet (90 meters) 330 feet (100 meters)
CAT6 / CAT6a / CAT7 330 feet (100 meters 330 feet (100 meters)

*Atlona recommends TIA/EIA 568-B termination for optimal performance.

LED Indicators

The PWR and LINK LED indicator on both the transmitter and receiver unit provides basic information on the current status of the AT-OME-EX-TX.

Mounting Instructions

The AT-OME-EX-TX provides two mounting brackets, which can be used to attach the unit to any flat surface. Use the two enclosure screws, on the sides of the unit to attach the mounting brackets.

  1. Using a small Phillips screwdriver, remove the two screws from the left side of the enclosure.
    Mounting Instructions

  2. Position one of the mounting brackets, as shown below, aligning the holes on the side of the enclosure with one set of holes on the mounting bracket.

  3. Use the screws from Step 1 to attach the mounting bracket.
    Mounting Instructions

  4. Repeat these steps to attach the second mounting bracket to the opposite side of the unit.

  5. Mount the unit to a flat surface using the oval-shaped holes, on each mounting bracket. If using a drywall surface, a #6 drywall screw is recommended.
    Mounting Instructions

Analyzer Software

The Analyzer software provides HD Base T testing, debugging,  and firmware update utilities. The software can be downloaded from the Resource tab located at https://atlona.com/product/at-ome-ex-kit/.

HD Base T Testing

  1. Launch the Analyzer software.

  2. Make sure the system is powered and the transmitter and receiver are connected using the HDBaseT OUT and HDBaseT IN ports.

  3. Connect an active source to the transmitter and an active display to the receiver. Set the source to the highest resolution.

  4. Connect a mini-USB to USB-A cable from the FW port, on the transmitter, to a computer.

  5. Click the Port drop-down list and select the COM port, then click the Connect button.
    Analyzer Software

  6. Click Quality in the menu bar.

  7. Click the Start button in the lower-right right corner of the window. The link information and cable pairing test results will display. Follow the instructions on the Analyzer software for any pair failures

Debug

  1. Launch the Analyzer software.

  2. Make sure the system is powered and the transmitter and receiver are connected using the HD Base T OUT and HD Base T IN ports.

  3. Connect an active source to the transmitter and an active display to the receiver. Set the source to the highest resolution.

  4. Connect a mini-USB to USB-A cable from the FW port, on the transmitter, to a computer.

  5. Click the Port drop-down list and select the COM port, then click the Connect button

  6. Click Debug in the menu bar.
    Analyzer Software

  7. lick the Debug button. Information will appear in the box field if there is any data that can be logged. The log can be saved to the local computer if needed.

Updating the Firmware

Requirements

  • AT-OME-EX-TX
  • Firmware file
  • Computer running Windows
  • USB-A to USB mini-B cable

NOTE: The update process can take up to five minutes to complete.

  1. Disconnect power from the unit.

  2. Connect a USB-A to USB mini-B cable between the PC and the FW port on the unit.

  3. Power the unit. Make sure the receiver is powered and a category cable is connected between the HD Base T ports of both the transmitter and receiver units.

  4. The USB UPDATE folder will be displayed. If this folder is not displayed, automatically, select the USB UPDATE drive from Windows Explorer.

  5. Delete all files from the USB UPDATE drive, if any are present.
    Analyzer Software

  6. Drag-and-drop the firmware file to the drive.

  7. The PWR LED indicator, on the front panel, will flash green while the unit is being updated. Do not disconnect the USB cable during the update process. When the PWR LED stops flashing and is solid green, the update process will be complete.

  8. Disconnect the USB cable from the unit and repeat for any additional units

Warranty

To view the product warranty, use the following link or QR code: https://atlona.com/warranty/.
QR code

English Declaration of Conformity
The English version can be found under the resources tab at:
https://atlona.com/product/at-ome-ex-tx/.
QR code

Chinese Declaration of Conformity

https://atlona.com/about-us/china-rohs/.

© 2022 Atlona Inc. All rights reserved. “Atlona” and the Atlona logo are registered trademarks of Atlona Inc. All other brand names and trademarks or registered trademarks are the property of their respective owners. Pricing, specifications and availability subject to change without notice. Actual products, product images, and online product images may vary from images shown here.

ATLONA Logo

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

ATLONA User Manuals

Related Manuals