VONROC GP527AC Automatic Pump Instruction Manual

June 9, 2024
VONROC

VONROC GP527AC Automatic Pump

VONROC-GP527AC-Automatic-Pump-product - Copy

SAFETY INSTRUCTIONS

Read the enclosed safety warnings, the additional safety warnings and the instructions. Failure to follow the safety warnings and the instructions may result in electric shock, fire and/or serious injury. Save the safety warnings and the instructions for future reference.
The following symbols are used in the user manual or on the product:

  • Read the user manual.
  • Denotes risk of personal injury, loss of life or damage to the tool in case of nonobser-vance of the instructions in this manual.
  • Indicates electrical shock hazard.
  • Protect the appliance against frost.
  • Max depth.
    • GP527AC: The guaranteed sound power level LWA = 77 dB(A)
    • GP528AC: The guaranteed sound power level LWA = 81 dB(A)
  • Do not dispose of the product in unsuitable containers.
  • The product is in accordance with the applicable safety standards in the European directives.

SAFETY NOTES
THIS APPLIANCE CAN BE USED BY CHILDREN AGED FROM 8 YEARS AND ABOVE AND PERSONS WITH REDUCED PHYSICAL, SENSORY OR MENTAL CAPA-BILITIES OR LACK OF EXPERIENCE AND KNOWL-EDGE IF THEY HAVE BEEN GIVEN SUPERVISION OR INSTRUCTION CONCERNING USE OF THE APPLIANCE IN A SAFE WAY AND UNDERSTAND THE HAZARDS INVOLVED. CHILDREN SHALL NOT PLAY WITH THE APPLIANCE. CLEANING AND USER MAIN- TENANCE SHALL NOT BE MADE BY CHILDREN WITHOUT SUPERVISION. IF THE SUPPLY CORD IS DAMAGED, IT MUST BE REPLACED BY THE MANUFACTURER, ITS SERVICE AGENT OR SIMILARLY QUALIFIED PERSON

IN ORDER TO AVOID A HAZARD. THE PLUG MUST BE REMOVED FROM THE SOCKETOUTLET BEFORE CLEANING OR MAINTAINING THE APPLIANCE.
Please read these instructions carefully and thoroughly before using this appliance and keep them for future reference. It is very important that you understand how to use this appliance safely so please take the time to familiarise yourself with the requirements as outlined in these instructions.

  • If you are in any doubt what so ever about using this appliance, we strongly recommend that you employ the services of a suitably qualified person.
  • Electrical connection must be protected by a residual current device (RCD) at the power socket with a nominal trip current of 30mA (max).
  • Keep children and pets well away from the work area and never allow children to use this appliance or touch the extension cord at any time.
  • When not in use, keep this appliance stored in a safe place out of reach of children.
  • Never leave the appliance unattended when inuse.
  • Never pull the appliance by its power cord. Carry it using the carry handle.
  • Do not allow the power cord to lay on or across sharp objects that might pierce the outer insulation.
  • Carry out a visual inspection of the power cord before use and if it is damaged, have it replaced by a specialist service centre. Do not use the appliance if the cord is damaged.
  • Keep the power cord away from heat, frost, oil, solvents or any sharp objects or edges.
  • Electrical connections e.g. extension cable, must be protected from moisture at all times.
  • Check that the power rating on your appliance corresponds with the power rating at you mains supply. The supply voltage must be 230VAC.
  • Never run this appliance dry – out of the water. If the appliance overheats, the thermal cut-out will switch it off. If this happens wait 5 minutes before using the appliance again.
  • Only switch the power back on with dry hands.
  • Never use this appliance in a pond or swimming pool while people are present in the water!
  • Do not use the pump for drinking water.
  • Corrosive, flammable or explosive substances, grease, oil, salt water and sewage must not be conveyed by the pump.
  • The pH of water must between 6.5 and 8.5.
  • The temperature of the liquid conveyed may not exceed 35 °C.

Electrical safety

When using electric machines always observe the safety regulations applicable in your country to reduce the risk of fire, electric shock and personalinjury. Read the following safety instructions and also the enclosed safety instructions.
Always check that the power supply corresponds to the voltage on the rating plate.

Connecting to the power supply Check that the power supply and plug used in accordance with your machine. Have a look at the rating plate on the machine. Any changes should always be carried out by a qualified electrician.

Warning  This machine must be earthed. If not properly earthed this machine can cause an electrical shock. Be sure that the power supply outlet is earthed. If there is any doubt, have it checked by a qualified electrician. Avoid contact with the terminals on the plug when installing (removing) the plug to (from) the power supply outlet. Contact will cause a severe electrical shock

Replacing cables or plugs

If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard. Immediately throw away old cables or plugs when they have been replaced by new ones. It is dangerous to insert the plug of a loose cable in the wall outlet.

Using extension cables
Only use an approved extension cable suitable for the power input of the machine. The minimum conductor size is 1.5 mm². When using a cable reel always unwind the reel completely.

MACHINE INFORMATION

The automatic pump is intended for private use for household water supply and irrigation of gardens, it is not intended for commercial use. Explosive, corrosive, flammable substances, sewage, salt water, grease and oil must not be conveyed by the pump. It is solely intended for pumping clear and rain water. The particle sizes of the solids in the water must not exceed the maximum particle size specified in the technical data.
This pump is not designed for continuous operation (e.g. as a swimming pool or pond circulation pump).

TECHNICAL SPECIFICATIONS

Model No. GP527AC GP528AC
Pump housing Plastic Stainless steel
Voltage 230 VAC / 50Hz
Input power 800W 1000W
Max. flow rate (Fig. C) 3300l/h 3500l/h
Max. pressure 4 bar 4.4 bar
Max. pumping height (Fig. C) 40m 44m
Max. self-priming suction height 8m
Max. particle size 1 mm (clean water)
Switch-on pressure 1.5-2.5 bar
Default switch-on pressure 1.5 bar
Dry run protection Yes
Pressure gauge Yes
Backflow preventer (pressure switch) Yes
Max. water temperature 35°C
Protection IPX4
Pressure connection (switch) G1″ external thread
Suction connection G1″ internal thread
Recommended inner hose diameter (suction hose) 25mm, 32mm, 38mm
Cable length 1.2m
Weight 6.86 kg 7.24 kg
--- --- ---

Sound pressure level LPA

| 62.6 dB(A)

K = 2.22 dB(A)

| 66.2 dB(A)

K = 2.66 dB(A)


Sound power level LWA

| 74.5 dB(A)

K = 2.22 dB(A)

| 78.1 dB(A)

K = 2.66 dB(A)

DESCRIPTION

The numbers in the text refer

  1. ON/OFF switch
  2. Drain plug
  3. Water inlet (pump)
  4. Foot valve / backflow preventer (not included)
  5. Filling plug
  6. Water outlet (pump)
  7. Carry handle
  8. Suction hose (not included)
  9. Water inlet (pressure switch)
  10. Water outlet (pressure switch)
  11. Pressure gauge
  12. Reset button
  13. LED-power
  14. LED-failure
  15. LED-on
  16. Pressure setting screw

ASSEMBLY

Before carrying out any work on the pump, disconnect the mains plug from the power supply.

Mounting the handle (Fig. D)VONROC-GP527AC-Automatic-Pump-
fig-6

  1. Put the handle (7) on the pump, as shown on figure D.
  2. Mount the handle (7) by tightening the two screws.

Installing the pressure switch (Fig. E)

  1. Screw the coupling into the pump outlet (6), as shown on figure E1.VONROC-GP527AC-Automatic-Pump-fig-7
  2. Screw the water inlet (9) connection into the coupling, as shown on figure E2.VONROC-GP527AC-Automatic-Pump-fig-8

Installing the pump (Fig. G)
The pump should be installed in ventilated and dry environment. It could be installed outside, provided having proper covering to prevent rain and wind. Make sure the pump is placed on the horizontal and stable ground. Always put up the garden pump at a point higher than the water surface, as shown on figure G.

Attaching the suction hose (Fig. A, F, G)VONROC-GP527AC-Automatic-Pump-
fig-2VONROC-GP527AC-Automatic-Pump-
fig-10

warning

Don’t use any hose connection system fittings or standard water hoses on the suction side! A suction hose (8) set with suitable coupling (G1″ external thread) and foot valve (4) must be used. The foot valve (4) prevents the return flow of the water at the end of the pumping process. 25mm, 32mm or 38mm (inner diameter) suction hose (8) must be used to achieve maximum flow rate. The suction hose (8) should be as short as possible.

  1. Remove the protection cap from the water inlet connection.
  2. Fill suction hose (8) with clean tap water, as shown on figure F.
  3. Apply thread seal tape (Teflon tape) to the threaded suction hose coupling.
  4. Screw the suction hose coupling airthight into the water inlet (3).
  5. T he foot valve (4) must be placed vertically and at least 30 cm from the water bottom to prevent the suction of sand and stones, as shown on figure G.

Attaching the outlet hose (Fig. B)

warning: The larger the hose and hose connector diameter, the greater the flow.
The lower the delivery height, the greater the flow.

  1. Decide which hose diameter and hose connecti-on system fittings you are going to use.
  2. Apply thread seal tape (Teflon tape) to the water outlet (10) connection.
  3. Screw the coupling (not included) on the water outlet (10).
  4. Connect the hose (not included) to the cou-pling.
  5. Check that the hose has no kinks in it.

Filling the pump with water (Fig. A, H)

  1. Unscrew and remove the filling plug (5).
  2. Fill the pump with clean tap water, as shown on figure H. Do not overfill the pump.
  3. Place the filling plug (5) back, do not overtighten.

OPERATION

caution:

  • Never use this pump in a pond or swimming pool while people are present in the water!
  • Only switch the power on or off with dry hands.
  • Never run this pump before the pump and the suction hose (8) is filled with water.
  • Clean the foot valve (not included) and pre-filter (not included) at regular intervals, and check it for damage. Otherwise, its function can be impaired.

Switching on/off (Fig. A)

  1. Check that the ON/OFF switch (1) of the pump is in the ‘O’ position before connecting the pressure switch to the power supply.
  2. Move the ON/OFF switch (1) of the pump into the position ‘I’ to switch the pump on.
  3. With the pressure switch you can automatically control the operation of a garden pump. Open the connected tap or spray gun to start the pump. When you start the pump, there will be a lot of air in the water first. This is not
    • a defect of your pump, but serves to remove air from the pump. It may take several minutes for the air to escape when the pump is used for the first time.
  4. When you close the connected tap or the spray gun, the pump automatically stops pumping.
  5. Move the ON/OFF switch (1) of the pump into the position ‘O’ to switch the pump off.

The pressure switch has 3 LED indicators (13, 14, 15) which indicate the status of the pressure switch:

LED indicators Operating status

LED-power (13)

| The pressure switch is connected to the power supply. The pressure switch is ready for use.



LED-failure (14)

| The pump is running dry without water. The dry-run safety is activated. Use the pump’s operating manual to find the cause of the failure and correct it. Then restart the pump by pressing the reset button (12) on the pressure switch.
LED-on (15)| The pump is operating.

Reading the pressure (Fig. B)
The pipe pressure can be read on the pressure gauge (11). The black scale indicates the pressure in bar.

Setting the switch-on pressure (Fig. A, B)
The default switch-on pressure is 1.5 bar. The switch-on pressure can be adjusted to a value between 1.5 bar to 2.5 bar.
It is possible to set the switch-on pressure by using the pressure setting screw (16). Every 360° turn decreases or increases the switch-on pressure for approx. 0.2 bar.

  • By turning clockwise, the pressure will be increased.
  • By turning anti-clockwise, the pressure will be decreased.

Finish operation (Fig. A, I)VONROC-GP527AC-Automatic-Pump-
fig-1

warning

  • Do not touch the pump unless its power has been cut off for at least 5 minutes.
  • When there is the risk of frost or if you do not use your pump for a long time, please properly store your pump.
  1. Check that the ON/OFF switch (1) is in the ‘O’ position.
  2. Remove the mains plug from the mains.
  3. Unscrew and remove the drain plug (2). Let the water drain.
  4. Pull up the suction hose (be aware, it is full of water).
  5. Unscrew the suction hose (8) from the water inlet (3).
  6. Remove the filter and foot valve (4), then rinse with clear water. Make sure that there is no water left in the suction hose (8).
  7. Remove the water hose from the water outlet (10). Unscrew the coupling from the water outlet (10).
  8. Place the drain plug (2) back, do not overtighten.
  9. Clean and store the device (see ‘Maintenance’)

MAINTENANCE

Before cleaning and maintenance, always switch off the machine and remove the mains plug from the mains.

VONROC-GP527AC-Automatic-Pump-fig-11

Clean the machine casings regularly with a soft cloth, preferably after each use. Remove very per-sistent dirt using a soft cloth moistened with soap-suds. Do not use any solvents such as gasoline, alcohol, ammonia, etc. Chemicals such as these will damage the synthetic components.
If the appliance appears to be blocked, switch off the power at the mains, remove the plug from the socket and check the appliance for blockages. Clean suction hose, foot valve, pre-filter and pump.VONROC-GP527AC-Automatic-Pump-
fig-12

STORAGE AND FROST PROTECTION
The garden pump and accessories that are not completely drained can be destroyed by frost. Completely drain the garden pump and accessories and protect them against frost. Keep this appliance in well-ventilated dry premises with temperature not going below +5°C. When not in use, keep this appliance stored in a safe place out of reach of children.

TROUBLESHOOTING GUIDE

Problem Cause Remedy
Pump does not start No mains supply

Pump not switched on

| Check mains supply Switch on pump
| LED-failure is on| Press the reset button
| Not enough pump pressure| Check that the pump pressure is 0.8bar higher than the starting pressure of the switch.
| The switch-on pressure is set too low| By turning the pres- sure setting screw clockwise, the switch-on pressure will be increased.
| The dry-run

safety is activated, because the

the switch-on pressure is set too high

| By turning the pres- sure setting screw anti-clockwise, the switch-on pressure will be reduced.
Pump is active but no water is being delivered (after being started

for more than 5 minutes)

| The pump is not fully filled with water


Air in the suction hose

| Re-fill the pump with water and check the suction hose foot valve


Check sealing of various joints of the suction hose

| Water level is too low| Adjust installation height of the pump (< 8 m)
| Suction hose, foot valve, pre-filter or pump is blocked| Clean suction hose, foot valve, pre-filter or pump
Pump does not stop or start and stop constantly| The switch-on pressure is set too high| By turning the pres- sure setting screw anti-clockwise, the switch- on pressure will be reduced.
Insufficient pressure| Incorrect pump type| Select suitable pump
---|---|---
| The suction hose is too long or with too many bends, suction hose diameter is not selected as required| 25mm, 32mm or 38mm (inner

diameter) suction hose must be used to achieve maximum flow rate. Make the suction hose shorter

| Suction hose, foot valve, pre-filter or pump is blocked| Clean suction hose, foot valve, pre-filter or pump
| The outlet hose is incorrectly or in- correctly installed| Check the outlet hose and connec- tions. The larger the diameter of the hose and the hose connection, the

greater the flow. The lower the delivery height, the greater the flow.

Pump will not start or stops during use.| Thermal overload safety switch has activated| Disconnect from the power supply, leave for 5 minutes and clean suction hose, foot valve, pre-filter or pump
Pump switched off after short op- erating periods| Power has tripped| Check fuses and electrical connec- tions
| Water too hot| Ensure that the wa- ter temperature has not exceeded the maximum of 35°C

ENVIRONMENT

Faulty and/or discarded electrical or electronic apparatus have to be collected at the appropriate recycling locations.

Only for EC countries
Do not dispose of power tools into domestic waste. According to the European Guideline 2012/19/EU for Waste Electrical and Electronic Equipment and its implementation into national right, power tools that are no longer usable must be collected separately and disposed of in an environmentally friendly way.

WARRANTY

VONROC products are developed to the highest quality standards and are guaranteed free of defects in both materials and workmanship for the period lawfully stipulated starting from the date of original purchase. Should the product develop any failure during this period due to defective material and/or workmanship then contact VONROC directly. The following circumstances are excluded from this guarantee:

  • Repairs and or alterations have been made or attempted to the machine by unauthorized service centers;
  • Normal wear and tear;
  • The tool has been abused, misused or improperly maintained;
  • Non-original spare parts have been used.

This constitutes the sole warranty made by compa-ny either expressed or implied. There are no other warranties expressed or implied which extend beyond the face hereof, herein, including the im-plied warranties of merchantability and fitness for a particular purpose. In no event shall VONROC be liable for any incidental or consequential damages. The dealers remedies shall be limited to repair or replacement of nonconforming units or parts.
The product and the user manual are subject to change. Specifications can be changed without further notice.

We declare under our sole responsibility that this product is in conformity with directive 2011/65/EU of the European parliament and of the council of 8 June on the restriction of the use of certain hazardous substances in electrical and electronic equipment is in conformity and accordance with the following standards and regulations:

GP527AC

  • Measured sound power level: 74.5 dB(A)
  • Guaranteed sound power level: 77 dB(A)

GP528AC

  • Measured sound power level: 78.1 dB(A)
  • Guaranteed sound power level: 81 dB(A)
  • Conformity assessment method to Annex V Directive 2000/14/EC amended by 2005/88/EC.
  • The notified body involved: TÜV SÜD Industrie Service GmbH, Certification Body of the Notified Body 0036

EN 60335-1, EN 60335-2-41, EN 62233, EN 55014-1, EN55014-2, EN 61000-3-2, EN61000-3-3, 2006/42/EC, 2014/30/EU, 2011/65/EU, (EU)2015/863, 2012/19/EU, 2000/14/EC, 2005/88/EC

WWW.VONROC.COM

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals