ELECTRO TERMINAL SLK 8-5 Luminaire Connection User Manual

June 12, 2024
ELECTRO TERMINAL

ELECTRO TERMINAL SLK 8-5 Luminaire Connection

Product Information

The SLK 8 is a connector with a radio module designed for the wiring of luminaires. It allows for easy installation and connection of lights. Please note that the installation of this product should only be done by qualified personnel.

Product Usage Instructions

Before starting any work on the device, ensure that the power supply is switched off. Follow the steps below to properly use the SLK 8:

  1. Drehen und ziehen (Twist and pull): Twist and pull the connector to open it.
  2. Leiter herausziehen (Pull out the wire): Pull out the wire from the connector.
  3. Push button: Press the button on the connector to prepare for wire insertion.
  4. Insert wire: Insert the wire into the connector.
  5. Release button: Release the button to secure the wire in place.
  6. Lochbild OF – Befestigungslasche (Cutout OF – Fixing tag): Use a torque wrench (max. 0.8 Nm) to secure the fixing tag with an M4 screw.
  7. ALP (Aluminiumprofil) Befestigung (ALP – Aluminium profile fixation): Use an M4 screw to attach the aluminum profile with a threaded channel of at least 0.5mm thickness.
  8. Antennenposition (Antenna position): Position the antenna according to your requirements.
  9. Anschlussdiagramm (Wiring diagram): Refer to the provided wiring diagram for proper connection, ensuring that protective earth-wiring is done according to the luminaire protection type.

Warning: This device should only be installed by qualified personnel. Always switch off the power supply before working on the device. Make sure to follow all applicable safety and accident prevention regulations. For more information, please visit www.electroterminal.com.

Wire insertion

  • Solid wires 0.5 – 2.5 mm²
  • Rigid stranded wires 1.5 – 2.5mm²
  • Insert wire to the back end

Flexible wires 0.5 – 2.5 mm² (upper terminals only)

  1. Push button
  2. Insert wire
  3. Release button

Wire release

Lower terminals

  1. Twist and pull
  2. Pull out the wire

Upper terminals

  1. Press button
  2. Pull out the wire

Test opening

Cutout E-SCHR (Standard fixing pin – screw earth tag)

Torque: max. 0.8 Nm

Cutout OF – Fixing tag

ALP (aluminum profile) fixation

Extruded aluminum profile with M4 thread channel

Minimum mounting distances
ELECTRO-TERMINAL-SLK-8-5-Luminaire-Connection-FIG-1
\(8\)

Dimensions

ELECTRO-TERMINAL-SLK-8-5-Luminaire-Connection-FIG-1
\(10\)

Antenna position

EC Ratings

  • Power supply voltage range 220 – 240 V
  • Mains frequency 50/60 Hz
  • Max Power input 1.5 W
  • Connectivity standards: Casambi-CBM003 radio module
  • Output: DALI (compatible)
  • Guaranteed output current DALI: 20 mA
  • Max. number of DALI devices: 6
  • Max. casing temperature: 70°C / 158°F
  • Type. power consumption in stand-by < 0,5 W
  • Operating frequency radio transceiver 2400 – 2480 Mhz
  • Max. transmitting power +8 dBm
  • Range Indoor: up to 30 m
  • Outdoor: up to 50 m
  • Protection class IP 20

Wiring diagram

ELECTRO-TERMINAL-SLK-8-5-Luminaire-Connection-FIG-1
\(12\)

Protective earth-wiring depending on the luminaire protection type
Warning! This device may only be installed by qualified personnel. The power supply must be switched off before working on the device. The applicable safety and accident prevention regulations must be observed!