The EuroSeries humidity temperature duct transmitter combines a capacitance- type relative humidity sensor and a temperature sensor in one IP65/NEMA4X housing, both with 0…10V output.
The EuroSeries humidity temperature duct transmitter is additionally equipped with a passive temperature sensor.
These temperature transmitters can be used :
- for checking and monitoring temperature and humidity in air duct applications (fresh air / exhaust);
- to avoid condensation in air duct applications;
- for humidification control.
FEATURES
- Wide sensing range
- Capacitance-type sensing element for rel. humidity
- Available with Passive Temperature Sensor
SPECIFICATION
Measured Values
- Relative humidity (0…10 V)
- Working range 10…90% %RH (non-condensing)
- Accuracy (active sensor) ±3% RH (30…70% RH) at 20 °C, otherwise ±5% RH
- Temperature dependency typically ±0.05% RH / °C Typical response time < 180 s
Temperature (0…10 V)
- Working range: -5…+55 °C (+23…+131 °F)
- Accuracy: ±0.3 °C at 20 °C
- Typical response time: < 180 s
General Specifications
- Power supply (Class III) for 0…10 V, 15…35 VDC or 24 VAC ± 20%
- Current consumption DC power supply: typ. 5 mA AC power supply: typ. 13 mAeff
- Connection Screw terminals, max. 1.5 mm2
- Housing material Polycarbonate, UL94V-2 appr.
- Protection class IP65 / NEMA 4 for enclosure; IP40 for sensing part (cap filter)
- Cable gland M16 x 1.5 / UL94-V2
- Sensor protection PE filter, non-removable
- EMC EN61326-1, EN61326-2-3; FCC Part 15, Class B; ind. environment: ICES-003 Issue 5 Class B
- Working conditions -5…+55 °C (+23…+131 °F), 0…95% RH (non-condensing)
- Storage conditions -25…+60 °C (-13…+140 °F), 20…80% RH
- Dimensions See Fig 1.
- Mounting Duct
- Approvals CE
Outputs
- Analog output 0…10 V ≡ 0…100% relative humidity / 0…50 °C (32…122°F)
- Passive temp. sensor 2-wire, passive sensor; wire resistance (terminal-sensor), typ. 0.5 W; temp. unit: °C
WIRING
- sensor to controller: maximum length 200 m (660 ft)
NOTE: Installation of the sensor near high EMI-emitting devices may lead to faulty measurements. Use shielded wiring in areas with high EMI. Keep 15 cm (5.9’’) min. distance between sensor lines and 230 Vac power lines. Use two transformers: one for sensors and actuators and one for the controller