POTTER PFC-7500 SERIES Fire Alarm Communicator Owner’s Manual

June 9, 2024
POTTER

POTTER PFC-7500 SERIES Fire Alarm Communicator

PFC-7500 SERIES FIRE ALARM COMMUNICATORS

  • Five zone communicator
  • One class A (style D) Waterflow Zone
  • Four class B Initiating Zones, smoke detector capable w/no additional modules.
  • Two optional Form C relays
  • Built-in dual phone line Module with Line Monitoring and 24 hour self test
  • 1.5 amp Notification Circuit (PFC-7501)
  • 500 mA Auxiliary output
  • LCD or LED Annunciators
  • Fire Drill feature
  • Contact ID, 4-2 or DMP SDLC Communication Formats
  • Remote Programmable
  • Available Cross Zoning
  • 16.5 VAC, 12 VDC or 24 VDC power input

Description

The PFC-7500 series fire alarm communicators provide reliable and efficient monitoring of sprinkler systems where fire alarm panels are not required. The PFC-7500 series has five input circuits, four Class B circuits and one Class A (Style D) circuit (waterflow zone). The PFC-7500 is a slave communicator that can be either connected for sprinkler system monitoring or as a slave communicator to an existing fire alarm panel. The panel comes standard with a Trouble Annunciator that mounts directly in the door of the panel. The panel must be powered with either a WLT transformer and back-up battery a 12VDC or 24VDC from a fire alarm panel with battery backup. The PFC-7501 is a complete fire alarm control panel with five input circuits and a 1.5 amp notification circuit. In addition, a total of 500-mA auxiliary power is provided. The panel provides a non supervised 12 VDC notification circuit. An optional module is available for a supervised notification circuit Class A/B (Style Z/Y). The PFC-7501 comes standard with the WLT wire in 16.5 VAC transformer. Either of the PFC-7500 series panels can be connected to a LCD or LED annunciator. The panels can be programmed using either a LCD annunciator or a computer and programming cable. In addition, the panels are remote programmable through Potter Link software. The PFC-7501 Alarm Communicator Kit is a PFC-7501 panel, a WLT 16.5 VAC transformer and a RA-7690 annunciator. The RA-7690 LCD annunciator is both a programmer and annunciator.

Ordering Information

  • 3003000 PFC-7500 Slave Communicator
  • 3003004 PFC-7501 Fire Alarm Communicator
  • 3003030 PFC-7501 Alarm Communicator Kit
  • 3003006 PFC-7501 without WLT Transformer
  • 3003003 PCB Assy for PFC-7500
  • 3003005 PCB Assy for PFC-7501
  • 3003001 RA-7690 LCD Annunciator
  • 3003002 RA-7692 LED Annunciator
  • 1000394 16.5 VAC Transformer
  • 1000314 Auxiliary Form C relay
  • 1000312 TAM Trouble Annunciator Module
  • 5130084 BT-80 8.0 AH Battery
  • 1000447 P32-1T Single Action Pull Station
  • 1000476 P32-1T-LP Dual Action Pull Station
  • 1430006 BPS-2 12/24 VDC Photo Smoke Detector
  • 1430026 BPS-2W White 12/24 VDC Photo Smoke
  • 1750070 6″ 12 VDC Bell
  • 1750080 8″ 12 VDC Bell
  • 1750060 10″ 12 VDC Bell
  • 1500001 Weatherproof Bell Backbox
  • 1000395 RJ 31X Phone Jack
  • 1000396 RJ 31X 4′ Plug to Plug Phone Cord
  • 1000313 DCP Programming Cable
  • 1000315 SNP Supervised Notification Module
  • 1000397 PPCJ Plug-Plug Cord w/RJ31X Jack

Engineering Specifications

The contractor shall furnish and install the Potter PFC-7500 series fire alarm communicator. The PFC-7500 shall be used as slave digital communicator for a fire alarm control panel or as a sprinkler-monitoring panel. The PFC-7500 shall have one Class A (Style D) waterflow zone and four programmable Class B initiating zones. In addition, the PFC-7500 shall have a Trouble Annunciator Module to indicate a Green LED for a normal system, a Yellow LED for trouble and a silence switch. A buzzer shall also annunciate a trouble condition. The PFC-7501 is listed as a fire alarm control panel and meets the requirements of UL 864. Similar to the PFC-7500 the system shall have one Class A (Style D) waterflow zone and four programmable Class B initiating zones. In addition, The PFC-7501 shall have a 1.5 amp notification output as well as a 100mA smoke detector output. Either panel shall be capable of being powered from a 16.5 VAC wire-in transformer or powered from a 12/24 VDC fire alarm control panel. The panel shall have an internal silence/reset switch. This switch shall silence the bell circuit and temporarily remove power from the auxiliary power (PFC-7501 only) and reset all latched devices on the input circuits. In addition, the panels shall communicate using Contact ID, Ademco 4-2 or DMP SDLC. The panel shall provide two RJ connectors for connecting to telephone lines. The panels shall support either LCD or LED annunciators. The panel shall supervise up to four (4) of the RA-7690 LCD annunciators. The panel shall be programmed either through the RA-7690 or through a computer program. The panel shall support two optional form C relays.

Specifications

  • pfc -7500 SERIES

  • Input –

  • Main –
    16.5 VAC, 12 VDC or 24 VDC
    (No Battery with 12 or 24 VDC)

  • Secondary –
    12 VDC 8.0 Ah battery

  • Auxiliary Output –
    500 mA 12 VDC

  • Alarm Output –
    1.5 Amps @ 12 VDC (PFC – 7501)

  • 4 Wire Smoke Detector Power –
    500 mA @ 12 VDC (PFC-7501)

  • Annunciator Output –
    50 mA each (switched ground)

  • Dimensions –
    12.5″ x 9.5″ x 3.75″

Potter Electric Signal Co., LLC
St. Louis, MO
Cust Service: 866-240-1870
Tech Support: 866-956-1211