POTTER AMS-51CV Insulation Displacement Surface Mount Contact Owner’s Manual
- June 9, 2024
 - POTTER
 
Table of Contents
 AMS-51CV Insulation Displacement Surface Mount Contact
Owner’s Manual
 AMS-51CV
INSULATION DISPLACEMENT
SURFACE MOUNT CONTACT
AMS-51CV Insulation Displacement Surface Mount Contact
- UL Listed
 - 1” operating gap
 - Simple installation
 - Alnico 5 magnet
 - Available in white, brown, gray, or ivory
 
Application
The AMS-51CV Surface Mount contact is a UL listed magnetic contact designed for quick installation using the patented insulation displacement method. Simply insert the unstripped wire and tighten the screw terminal. The AMS-51CV contact can be used to protect openings such as man doors, sliding doors, and windows.
Dimensions

Exclusive 5-Point Contact
Specifications
Model| Color| Stock
Number| Contact| Contact
Rating| Contact
Type| Max.
Carry
Current| Max’
Switching
Current| Breakdown
Voltage| Operating
Gap| Mounting
Method| Operating
Temperature
Range
---|---|---|---|---|---|---|---|---|---|---|---
AMS-5ICV| White| 4350213| Terminal| 10VA| Form A
N.O.| 1.0 Amp| .3 Amp| 200VDC
min.| 1″| Screw in
or self-
adhesive| 32°F to 120°F
(0°C to 49°C)
Brown| 4350211
Gray| 4350212
Ivory| 4350082  
 Potter Electric Signal Co., LLC
St. Louis, MO
Cust Service: 866-240-1870
Tech Support: 866-956-1211
Canada 888-882-1833
www.pottersignal.com
PRINTED IN USA
MKT. #8880117 – REV B