contacta V15a Series Hearing Loop Drivers User Guide
- June 6, 2024
- contacta
Table of Contents
- contacta V15a Series Hearing Loop Drivers
- Product Overview
- Components
- Connections
- Suitable Cable Lengths
- Driver Area Coverage
- Start-Up Tests
- Controls
- Hearing Loop Setup
- Troubleshooting
- Technical Specification
- Standards
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
contacta V15a Series Hearing Loop Drivers
Contacta has a policy of continuous product development, therefore small specification changes may not be reflected in this manual. Images, labels, packaging, accessories and product colors are subject to change without notice.
Product Overview
- Our highly efficient and compact V7+, V15+, and V15a+ hearing loop drivers are suitable for smaller facilities and venues.
- The V7+ and V15+ are constant current hearing loop drivers that power hearing loops utilizing a single output. The V15a+ is a constant current dual output hearing loop driver with an integral phase shifter for phased array configuration.
- These hearing loop drivers offer features that are usually found in more expensive hearing loop drivers.
- Features such as selectable High-Pass filters, audio signal delay, and switchable AGC are now available in these entry-level drivers. These features are enabled through the use of an advanced audio subsystem based on DSP.
- Coupled with efficient Class D output stages allows the V+ range of drivers to achieve life-like speech and first-class music reproduction.
Note: For large area hearing loop installation instructions, consult the Large Area Hearing Loop Installation Guide.
Components
- Rubber Feet x4
- 5.08mm Euro-Block Connector
- 3.81mm Euro-Block Connector x2
- Signage
- V7+ Hearing Loop Driver
- Installation & User Guide
- Power Supply [PS-55]
- IEC Power Lead*
-
Rubber Feet x4
-
5.08mm Euro-Block Connector
-
3.81mm Euro-Block Connector x2
-
Signage
-
V15+ Hearing Loop Driver
-
Installation & User Guide
-
Power Supply [PS-60]
-
IEC Power Lead*
-
Rubber Feet x4
-
5.08mm Euro-Block Connector x2
-
3.81mm Euro-Block Connector x2
-
Signage
-
V15a+ Hearing Loop Driver
-
Installation & User Guide
-
Power Supply [PS-60]
-
IEC Power Lead*
lug type varies by country.
Cable & Equipment: A length of loop cable determined by the loop design is also required. Hearing loop drivers also require ancillary equipment for audio feeds, such as a microphone or sound system.
Connections
Rear Panel Connections
- Microphone Input – 3.81mm Euro-block balanced microphone input (12V phantom power via 680Ω).
- Line Input 1* – 3.81mm Euro-block balanced line input/feedthrough.
- Line Input 2* – XLR balanced line input/feedthrough.
- Power Supply Input – *V7+ DC Power Input, 2.1mm 14Vdc 2.14A
- V15+ DC Power Input, 2.1mm 24Vdc 4.17A
- V15a+ DC Power Input, 2.1mm 24Vdc 4.17A
- Caution: Use only the provided Power Supply.
- Loop A Output – 5.08mm Euro-block.
- Loop B Output – 5.08mm Euro-block [V15a+ only].
Note: Only connect to one Line Input at a time.
Connection Examples
Suitable Cable Lengths
The tables in this section show the approximate maximum cable lengths for differing maximum required currents. Loop impedance (at 1.6kHz) should be less than the voltage capability of the driver (V7+: 7.5Vrms, V15+: 15Vrms, V15a+: 15Vrms) divided by the required current. This achieves 400mA/m field strength at 1kHz.
V7+ Single-Turn Hearing Loop (Metric)
Current | 2.0A | 3.0A | 4.0A | 5.0A | |
---|---|---|---|---|---|
Cable Type | Cable Length | ||||
Maximum Cable Length | Round Cable (CSA) | 0.5mm | 85m | 56m | 42m |
1mm | 133m | 89m | 66m | 53m | |
1.5mm | 155m | 103m | 77m | 62m | |
2.5mm | 173m | 115m | 86m | 69m | |
Flat Cable (Width) | 10mm | 101m | 67m | 50m | 40m |
12.5mm | 192m | 128m | 96m | 77m | |
25mm | 255m | 170m | 127m | 102m |
V7+ Single-Turn Hearing Loop (Imperial)
Current | 2.0A | 3.0A | 4.0A | 5.0A |
---|
Cable Type| Cable Length
Maximum Cable Length| Round Cable (AWG)| 18AWG| 438ft| 292ft| 219ft| 175ft
14AWG| 593ft| 395ft| 296ft| 237ft
Flat Cable (Width)| 18AWG
(equivalent)
| 505ft| 336ft| 252ft| 202ft
14AWG
(equivalent)
| 711ft| 474ft| 355ft| 284ft
V15+ Single-Turn Hearing Loop (Metric)
Current | 2.0A | 3.0A | 4.0A | 5.0A |
---|
Cable Type| Cable Length
Maximum Cable Length| Round Cable (CSA)| 1mm| 242m| 161m| 121m| 97m
1.5mm| 284m| 189m| 142m| 114m
2.5mm| 319m| 213m| 160m| 128m
Flat Cable (Width)| 10mm| 180m| 120m| 90m| 72m
12.5mm| 340m| 226m| 170m| 136m
25mm| 450m| 300m| 225m| 180m
V15+ Single-Turn Hearing Loop (Imperial)
Current | 2.0A | 3.0A | 4.0A | 5.0A |
---|
Cable Type| Cable Length
Maximum Cable Length| Round Cable (AWG)| 18AWG| 746ft| 498ft| 373ft| 299ft
14AWG| 997ft| 664ft| 498ft| 399ft
Flat Cable (Width)| 18AWG
(equivalent)
| 840ft| 560ft| 420ft| 336ft
14AWG
(equivalent)
| 1327ft| 885ft| 663ft| 531ft
V15a+ Single-Turn Hearing Loop (Metric)
Current | 2.0A | 3.0A | 4.0A | 5.0A |
---|
Cable Type| Cable Length
Maximum Cable Length| Round Cable (CSA)| 1mm| 266m| 177m| 133m| 106m
1.5mm| 311m| 208m| 156m| 125m
2.5mm| 350m| 233m| 175m| 140m
Flat Cable (Width)| 10mm| 197m| 131m| 99m| 79m
12.5mm| 373m| 249m| 186m| 149m
25mm| 493m| 329m| 247m| 197m
V15a+ Double-Turn Hearing Loop (Metric)
Current | 2.0A | 3.0A | 4.0A | 5.0A |
---|
Cable Type| Cable Length
Maximum Cable Length| Round Cable (CSA)| 1mm| 193m| 129m| 97m| 77m
1.5mm| 209m| 139m| 104m| 83m
2.5mm| 219m| 146m| 110m| 88m
Flat Cable (Width)| 10mm| 172m| 115m| 86m| 69m
12.5mm| 267m| 178m| 133m| 107m
25mm| 316m| 211m| 158m| 126m
V15a+ Single-Turn Hearing Loop (Imperial)
Current | 2.0A | 3.0A | 4.0A | 5.0A |
---|
Cable Type| Cable Length
Maximum Cable Length| Round Cable (AWG)| 18AWG| 819ft| 546ft| 409ft| 328ft
14AWG| 1093ft| 729ft| 547ft| 437ft
Flat Cable (Width)| 18AWG
(equivalent)
| 921ft| 614ft| 461ft| 369ft
14AWG
(equivalent)
| 1456ft| 971ft| 728ft| 582ft
V15a+ Double-Turn Hearing Loop (Imperial)
Current | 2.0A | 3.0A | 4.0A | 5.0A |
---|
Cable Type| Cable Length
Maximum Cable Length| Round Cable (AWG)| 18AWG| 598ft| 399ft| 299ft| 239ft
14AWG| 684ft| 456ft| 342ft| 273ft
Flat Cable (Width)| 18AWG
(equivalent)
| 723ft| 482ft| 362ft| 289ft
14AWG
(equivalent)
| 949ft| 633ft| 475ft| 380ft
Driver Area Coverage
Note: A full site survey of an installation area is recommended for optimal loop design.
Perimeter Loops Perimeter loop areas detailed in the table on page 13 are valid only when the following conditions are met:
- Area is at the maximum current the driver is capable of delivering without voltage clipping at 1.6KHz
- Loop layout is designed to achieve 0dB in the centre
- 25mm x 0.1mm flat copper cable
- Loop is installed in the floor
- Listening height 1.2m (large perimeter loops may have areas where the actual signal level is higher than required)
Phased Array Loops
Phased array loop areas detailed in the table on page 13 are valid only when
the following conditions are met:
- Area is at the maximum voltage the driver is capable of delivering without voltage clipping at 1.6KHz
- Layout of 3m segment widths
- 25mm X 0.1mm flat copper cable is used
- Loop is installed in the floor
- Listening height 1.2m
- Medium metal loss = 6dB
Area | |
---|---|
Voltage |
Perimeter loops
V7+| 7.5V| 5.0A| | 95.06m²| 143.00m²| 178.64m²
V15+| 15.0V| 5.0A| 95.06m²| 143.00m²| 178.64m²
Phased array (no metal loss)
V15a+| 15.0V| 5.0A| | 625.00m2| 684.50m²| 705.33m²
Phased array (medium metal loss)
V15a+| 15.0V| 5.0A| | 289.00m²| 288.00m²| 408.33m²
Start-Up Tests
V+ Series drivers perform a series of tests when powered on, causing several indications to appear on the display screen during start-up.
Indicator | Meaning | Remedy |
---|
V7+ and V15+:
Loop Good
V15a+:
Loop A Good Loop B Good
| Hearing loop(s) is/are correctly
connected to the driver.
| None required.
V7+ and V15+:
Loop Open Fault
V15a+:
Loop A Open Fault Loop B Open Fault
| Hearing loop(s) is/are improperly
connected to the driver.
An open-circuit loop will not damage the driver, and start-up will continue to the main menu.
| Ensure that the loop(s) is properly connected to the driver. The
loop current indication in normal operation may be used to confirm the connections.
V7+ and V15+:
Loop Ground Fault
V15a+:
Loop A Ground Fault Loop B Ground Fault
| A ground fault with the hearing
loop(s) has been found.
The driver will halt operation with this message displayed on screen, as such a fault would cause stress to the driver were normal operation to continue.
| Switch off the driver and carefully check the loop(s) for shorts to ground. Rectify the faults and re- apply power to the driver.
Please contact your distributor (or Contacta if appropriate) if technical difficulties persist.
Incorrect Power| The power input supply voltage from the mains power supply is incorrect.
The driver will halt operation with this message displayed on screen, as such a fault would cause stress to the driver were it to continue to normal operation.
| Switch off the driver and connect the power supply which was provided with the driver. If this
is not available, contact your distributor to order a new power supply.
Please note if using V15a+: If connecting only one loop to a V15a+, whichever loop connection has not been used (either Loop A or Loop B) will show as an “Open Fault” as default. This is the correct display for operation with only one loop; continue as normal.
Please contact your distributor (or Contacta if appropriate) if you are experiencing technical difficulties with the product.
Controls
Front Panel Overview
V7+ and V15+
- Clip Status Light – When lit, this status LED indicates the signal on the hearing loop output is clipping (see Troubleshooting on page 30 for appropriate solutions).
- Display Screen – Indicates the status of the Loop Output, displays menu and adjustment options.
- Control Dial – Used for unlocking and making adjustments.
V15a+
- Clip Status Light – When lit, this status LED indicates the signal on Hearing Loop A is clipping (see Troubleshooting on page 30 for appropriate solutions).
- Clip Status Light – When lit, this status LED indicates the signal on Hearing Loop B is clipping (see Troubleshooting on page 30 for appropriate solutions).
- Display Screen – Indicates the status of the Loop Output, displays menu and adjustment options.
- Control Dial – Used for unlocking and making adjustments.
Locking/Unlocking the Hearing Loop Driver
The hearing loop driver will power up in Output Current Display Mode and will
be locked from entering Adjustment Mode.
Unlock the Driver
- To unlock the hearing loop driver, press the control dial, and when prompted “Unlock driver?” click “Yes.”
- Enter the passcode 2239:
- a. Rotate the control clockwise to select the first required digit.
- b. Press the control dial in to select the digit.
- c. Repeat steps (a) and (b) until all the digits have been selected.
Note: Entering the wrong code returns the hearing loop driver to the lock screen.
Additional Functions and Codes
- To access one of the additional functions available, press the control dial, and when prompted “Unlock driver?” click “Yes.”
- Enter one of the following passcodes:
- 1010: Disable the display backlight 10 minute auto switch-off. This setting is remembered through power cycles.
- 1011: Enable the display backlight 10 minute auto switch-off. This setting is remembered through power cycles.
- 9999: Disable the auto re-lock (timeout). This is not remembered through power cycles.
- 8888: Restore all factory defaults and restart the driver.
Modes
Main Menu
After being unlocked, the hearing loop driver will display the main menu. This
is indicated by up and down arrows on the display screen.
When in this mode, rotating the hearing loop driver’s control dial clockwise will move the screen to the next menu item and rotating the dial anti- clockwise will move it to the previous menu item.
The menu options are as follows:
V7+ and V15+
- Loop Output
- AGC On/Off
- Line Input
- Phantom Power
- Microphone Input
- Current Output (no adjustment)
- High-Frequency Compensation
- Input High Pass Filter
- Audio Delay
V15a+
- Loop Output
- Line Input
- Phantom Power
- Microphone Input
- Loop B Trim Adjustment
- High-Frequency Compensation
- High Pass Filter
- Audio Delay
- AGC On/Off
Adjustment Mode
Press the control dial-in to enter Adjustment Mode; the arrows on the display
screen will move to a left and right position. Rotate the dial clockwise or
anti-clockwise to adjust. Press the control dial in to confirm the selection
and return to the main menu.
If the control dial is not used for 120 seconds when in Adjustment Mode the hearing loop driver will revert to the main menu, with Loop Output as the default screen.
Loop Output
The hearing loop driver’s Loop Output section displays the real-time output current in 0.5A steps.
Adjustments
In Adjustment Mode, the real-time output current is displayed on the top line in 0.5A steps. The bottom line indicates the strength of the loop output level adjustment.
To alter the loop output level, enter Adjustment Mode
- To increase the loop output level, rotate the control dial clockwise.
- To decrease the loop output level, rotate the control dial anti-clockwise.
- Press the control dial once to confirm the selection and return to the main menu.
AGC On/Off
The AGC function can be switched on or off from this screen. For normal set-up
and operation and optimal performance, it is recommended the AGC is left on.
- To switch the AGC off, rotate the control dial clockwise.
- To switch the AGC on, rotate the control dial anti-clockwise.
- Press the control dial once to confirm the selection and return to the main menu.
Adjustments
Line Input
The hearing loop driver’s Line Input section displays the line input level within a range of 47dB. The text on the display indicates if the correct line level has been achieved:
- “Low” indicates the line level is too low for the automatic gain control to operate.
- “Good” indicates the line level is at an optimum level for the automatic gain control to operate.
- “High” indicates the line level is too high and signal clipping may occur. Signal clipping will also be shown by the LED.
Adjustments
It is recommended that at least 5 blocks in the adjustment block are filled (see the above image for an example). Enter Adjustment Mode, and alter the line input level displayed on the bar until the text displays ‘Good’:
- To increase the line input level, rotate the control dial clockwise.
- To decrease the line input level, rotate the control dial anti-clockwise.
- Press the control dial once to confirm the selection and return to the main menu.
Phantom Power
Phantom power for a connected microphone is set off as the default setting.
Adjustments
Rotating the control dial clockwise or anti-clockwise in Adjustment Mode will toggle the phantom power on or off. Press the control dial once to confirm the selection and return to the main menu.
Microphone Input
The hearing loop driver’s Microphone Input section displays the microphone input level within a range of 47dB.
The top line of the display indicates if the correct microphone input level has been achieved:
- “Low” indicates the microphone level is too low for the automatic gain control to operate.
- “Good” indicates the microphone level is at an optimum level for the automatic gain control to operate.
- “High” indicates the microphone level is too high and signal clipping may occur. Signal clipping will also be shown by the LED.
Adjustments
It is recommended that at least 5 blocks in the adjustment block are filled (see the above image for an example). Enter Adjustment Mode and alter the microphone input level displayed on the bar until the text displays ‘Good’:
- To increase the microphone input level, rotate the control dial clockwise.
- To decrease the microphone input level, rotate the control dial anti-clockwise.
- Press the control dial once to confirm the selection and return to the main menu.
Input High Pass Filter
This feature removes low-frequency sounds from the hearing loop when background noise such as air conditioners might impact users. Select either 150Hz or 180Hz if required.
Adjustments
Rotating the control dial clockwise or anti-clockwise in Adjustment Mode to
toggle between the 150Hz and 180Hz cut-off or turn the filter off. Press the
dial once to confirm the selection and return to the main menu.
Audio Delay
In theatres, stadiums and other large venues, sound sent from speakers will be impacted by the speed of sound, whereas audio sent through a hearing loop will reach a user instantly. This means the two sounds must be aligned or users will hear a constant echo.
Adjustments
After syncing and compensate for latency.
- To increase the delay, rotate the control dial clockwise.
- To decrease the delay, rotate the control dial anti-clockwise.
- Press the control dial once to confirm the selection and return to the main menu.
V15a+ Only: Loop Trim
When using a V15a+, the hearing loop driver’s Loop Trim function allows Loop B’s output to be adjusted relative to Loop A’s output.
Please note: This section is only available on the V15a+. The equivalent V7+ and V15+ menu displays Current Output, to which adjustments can be made using the Loop Output section (see page 18). When in the Loop Trim section, adjustments are made in 1dB steps. The measured loop output current is displayed in amps RMS (accurate for sine signals).
Adjustments
Enter Adjustment Mode to alter “Loop B Trim” relative to “Loop A”.
- To increase the Loop B Trim level, rotate the control dial clockwise.
- To decrease the Loop B Trim level, rotate the control dial anti-clockwise.
- Press the control dial once to confirm the selection and return to the main menu.
High-Frequency Compensation
There are 7 levels of high-frequency compensation available to adjust for metal loss. Your hearing loop driver will have high-frequency compensation turned to the lowest setting as its default.
Adjustments
To alter the high frequency compensation level, enter Adjustment Mode:
- To increase the high-frequency compensation level, rotate the control dial clockwise.
- To decrease the high-frequency compensation level, rotate the control dial anti-clockwise.
- Press the control dial once to confirm the selection and return to the main menu.
To calculate the correct high-frequency compensation level, refer to Setup on page 24.
Hearing Loop Setup
To ensure optimal performance of a V7+, V15+ or V15a+ hearing loop driver, setup should be performed in following order:
- Step 1: Background Noise Level
- Step 2 : Metal Loss
- Step 3 : Output Level and Clipping
- Step 4 : Field Uniformity
- Step 5 : Final Output Level Adjustment
- Step 6 : Input Signal Level Adjustment
Required for Setup
- TSG – Contacta Test Signal Generator (TSG1)
- FSM – Contacta Field Strength Meter (IL-CONTACTA-FSM)
- Tripod or similar for mounting the FSM is recommended
- ‘Compliance Certificate’ document
Note: Throughout set-up, record values on the provided Compliance Certificate document whenever you see the following icon: The Compliance Certificate document confirms compliance with IEC-60118:4 if your values are within acceptable levels. It is highly recommended that you retain a copy of the completed Compliance Certificate document for your records and provide a copy to the relevant facilities manager.
Step 1: Background Noise Level
This test should be performed prior to loop installation.
-
Set up the FSM, ensuring that the two vertical arrows in the top-right corner of the device are placed at the correct height:
- 1.2 metres (3’ 9”) for seated user.
- 1.7 metres (5’ 6”) for standing users.
A tripod or similar for mounting the FSM is recommended.
-
Any lights or equipment normally active in the surrounding area should be turned on to ensure an accurate testing environment.
-
Set the FSM to the Background Noise mode – “A-weighted”.
-
Measure and note the background noise level throughout the looped area on the Compliance Certificate document.
-
Listen to the loop through the FSM (A-weighted) or a loop listener (A-weighted). Note and demonstrate any interference to the customer which may not be heard through a hearing instrument.
-
Background magnetic noise must be between -32dB and -60dB. If the readings noted pass the Compliance Certificate document’s requirements, move on to Step 2: Metal Loss.
Step 2: Metal Loss
-
Set up the FSM, ensuring that the two vertical arrows in the top-right corner of the device are placed at the correct height:
• 1.2 metres (3’ 9”) for seated user.
• 1.7 metres (5’ 6”) for standing users.
A tripod or similar for mounting the FSM is recommended. -
Connect the TSG to the line input of the hearing loop driver.
-
Set the TSG to the 1kHz setting.
-
Set the FSM to the Third Octave F= 1000Hz setting.
-
Adjust the line level until “Good” is displayed.
-
Adjust the drive level to achieve 2 amps of output current.
-
Set the TSG to the pink noise setting and record the value measured by the FSM.
-
Set the FSM to the Third Octave F= 100Hz setting and record the value measured.
-
Set the FSM to the Third Octave F= 5000Hz setting and record the value measured.
-
If the difference between the values measured at 1000Hz and 5000Hz is less than 3dB, record the results and move on to Step 3: Output Level and Clipping. If the difference is higher than 3dB, move on to step 11.
-
Increase the HF comp and repeat steps 3 to 10.
Step 3: Output Level and Clipping
Note: This test should be performed as briefly as possible.
-
Set the TSG to the 1kHz setting.
-
Set the FSM to the RMS/Peak A-Weighted mode.
-
Adjust the drive level to achieve 2 amps of output current.
-
Measure the field strength. Achieve 0dB by using the FSM’s indicated field strength to work out the extra current required. For example: if the measured field strength on the FSM is (A-RMS) – 6dB then 6dB (2X) extra current will be required to achieve 0dB (see Note 1 on page 29).
Note: If more than 7.9dB is required to achieve 0dB, a different loop design or more powerful driver is required. This is potentially due to metal loss. -
Briefly alter the current to the desired level. For instance, the example in step 4 requires 4 amps of current.
-
The field strength will now be 0dB +/- 1dB.
-
Quickly record the current required to achieve 0dB field strength. Now switch the TSG to 1.6kHz.
-
Confirm that the Loop A and Loop B Clip LEDs remain unlit.
-
If the driver’s front panel Clip LEDs remain unlit, return the TSG to 1kHz and reduce output current to 2 amps move on to Step 4: Field Uniformity.
If the driver’s front panel Clip LEDs are lit, the driver is clipping. This means the loop connected is too long, and therefore:
- The system is not IEC60118-4 compliant.
- The sound will be distorted.
- The driver may be susceptible to damage and warranty voided.
Perform one of the following solutions and repeat until there is no clipping:
- Reduce the loop current,
- Reduce the length of the loop,
- Use a higher diameter of flat cable,
- Try a two-turn loop,
- Use a higher voltage driver.
Step 4: Field Uniformity
- Set up the FSM. Ensure that the two vertical arrows in the top-right corner of the FSM are placed at the correct height:
• 1.2 metres (3’ 9”) for seated user.
• 1.7 metres (5’ 6”) for standing users.
A tripod or similar for mounting the FSM is recommended.
- Reduce the loop output current to 2 amps.
- Set the FSM to the RMS/Peak A-Weighted mode and record the value measured by the FSM in the centre of the loop.
- Move the FSM to other user positions within the looped area and record the values measured by the FSM.
- The differences measured in other positions should not be greater than +/- 3dB of that measured in the first position.
- Repeat steps 3 to 5 to create a suitable map of the area looped.
Step 5: Final Output Level Adjustment
- Set the TSG to 1kHz.
- Adjust the output current to the level recorded in Step 3: Output Level and Clipping (7) on page 27. Once the current is set, disconnect the TSG.
Step 6: Input Signal Level Adjustment
- Connect the system signal source.
- Adjust the input level (line/mic) level until “Good” is displayed on audio peaks.
- The system is now set up.
Note 1:
When adjusting the output current, if a level of 2.5 amps is reached and yet
the field strength is still below -6dB, the correct field strength will not be
achieved. This is caused by either an incorrect loop design or installation,
more metal loss than expected or an incorrectly specified driver. There is no
need to go higher than +0dB ARMS.
Adjustment to drive current/level required based on the measured field strength:
Measured Field Strength| Output current that
will achieve 0dB
| Steps to increase Drive| Steps to decrease Drive
---|---|---|---
6.00dB| 1.00A| | 6
5.00dB| 1.12A| | 5
4.00dB| 1.26A| | 4
3.00dB| 1.42A| | 3
2.00dB| 1.59A| | 2
1.00dB| 1.78A| | 1
.00dB| 2.00A| 0| 0
-1.00dB| 2.24A| 1|
-2.00dB| 2.52A| 2|
-3.00dB| 2.83A| 3|
-4.00dB| 3.17A| 4|
-5.00dB| 3.56A| 5|
-6.00dB| 3.99A| 6|
-7.00dB| 4.48A| 7|
-8.00dB| 5.02A| 8|
-9.00dB| 5.64A| 9|
-10.00dB| 6.32A| 10|
-11.00dB| 7.10A| 11|
-12.00dB| 7.96A| 12|
-13.00dB| 8.93A| 13|
-14.00dB| 10.02A| 14|
Troubleshooting
Symptom | Possible Fault | Action |
---|---|---|
The driver does not turn on. | 1) Mains power is absent. |
2) Internal failure.
| 1) Check mains power.
2) Seek assistance.
Interference (buzzing/ whistling/hissing) is heard through induction loop.| 1) Bad input signals.
2) Internal failure.
| 1) Power off the hearing loop driver and confirm that interference isn’t from an external origin.
2) Disconnect input signals. If the sound disappears, check inputs.
The driver is excessively hot
to touch.
| 1) Large amount of mains hum present on the input.
2) Internal failure.
| 1) Check the input signal source.
2) Incorrect hearing loop
driver being used.
The loop output level indicates current is flowing but I hear nothing in the loop.| 1) Shorted feeder cable.
2) Loop listener is not working or being used too far from loop.
| 1) Check the feeder cable, although the hearing loop driver will usually refuse to tune to the shorted feeder.
2) Check listener and location.
The sound is distorted.| 1) Input level has been turned up too high for signal level at input.
2) Input signal is distorted.
3) Output signal is clipping.
| 1) Reduce input level setting.
2) Check signal source.
3) Refer to “The Clipping Status Lights are lit” below.
The Clipping Status Lights
are lit.
| The connected hearing loop is
too long.
| 1) Reduce the length of the loop.
2) Use a larger diameter
cable.
3) Create a two-turn loop.
4) Use a higher voltage driver.
Please contact your distributor (or Contacta if appropriate) if you are experiencing technical difficulties with the product.
Loop Ground Fault
This image indicates the driver has detected a fault with the loop.
Diagnosing the fault
Step 1
Recycle the mains power. If the error message is displayed again move onto
step 2.
Step 2
Remove the power and disconnect the loop(s). Using a multi-meter measure the
resistance of the loop. This measurement should be made at the Euroblock
connector between the conductors. The reading should be below the following
values:
- V15a+ <12Ω
- V15+ <12Ω
- V7+ <6Ω
If the loop resistance is higher than these values but not an open circuit, then:
- The loop connected (including feeder cable) exceeds the maximum Resistance due to being either too long or too small a gauge or a combination of both. The reason should be investigated.
- If the reading is open circuit, then there is most likely a break in the loop or feeder cable. The reason should be investigated.If the loop resistance is withing these values (typically less than half these values) then the fault could be caused by the loop being connected to mains or building ground (Earth).
Step 3:
- With the mains power removed, disconnect the loop connector.
- Using a multimeter measure the resistance of the loop connections and a suitable ground/earth connection, such as the chassis of an earthed piece of electrical equipment, exposed metal pipes (water or gas) or conduit.
- This should be measured using a multi-meter on the Megaohms (MΏ) range.
- The reading should be greater than 10MΩ, be careful not to touch any of the meter connections as this will affect the measurement.
- If the reading is higher than 10MΩ or the meter reads O/C (open circuit) on the V15a+ move on to step 4. For V15+ and V7+ contact your supplier or installer for advice.
- If the reading is lower than 10MΩ then the loop insulation needs checking.
- Very low readings may indicate a serious fault with the loop insulation. This should be rectified before proceeding.
Step 4:
- Using a multimeter on the Megaohms (MΩ) range, measure the resistance between both loops. The reading should be greater than 10MΩ be careful not to touch any of the meter connections as this will affect the measurement.
- If the reading is lower than this check the loop/feeder cable insulation and points where the loops are in physical contact with each other.
- If the reading is higher than 10MΩ or the meter reads O/C (open circuit), contact your supplier or installer for advice.
Technical Specification
V7+
Power
- 2.1mm 30W 14Vdc 2.14A via External PSU (PS-55)
- Class 6 External PSU (100V -240V AC 50Hz-60Hz)
Inputs
- 1 X Line XLR or 3.81mm Euro-block [optimised for -10dBV to 0dBv]
- 1 X Microphone (12V phantom power via 680Ω) [optimised for levels above -45dBv]
Output Characteristics
- Output Voltage : 7.5Vrms (21.21Vpk-pk) @ 5Arms (14.14Apk-pk) see notes 1 and 2
- Output Current : 5Arms (14.14Apk-pk) up to 300 seconds
- Loop Connector: 5.08mm Euro-block
Audio system
- Frequency Response: 80Hz to 9kHz
- Distortion: THD+N <1% (-40dB)
- AGC: Peak detecting
- HF Comp : 7 optimised stages
- Audio Delay: 1ms – 70ms in 1ms steps
- High Pass Filter: Off/150Hz/180Hz
Note 1: Z=1.4Ω (133uH +0.685Ω @ 1.6kHz) Note 2: < 1% (-40dB) distortion
Display & Control
- Display: LED Backlit LCD display
- Control: Single rotary control
Fault Monitoring and Protection
- Main Display : Open circuit loop (DCR measurement) Loop ground fault
- Front Panel LED : Output voltage clipping
- Cooling : Internal heatsinks with thermal protection
Physical
- Height: 42mm (1.65”)
- Depth: 132mm (5.20”) [150mm (5.90”) including XLR and control knob]
- Width: 198mm (7.80”)
- Weight: 938g (2.06lbs)
V15+:
Power
- 2.1mm 100W 24Vdc 4.17A via External PSU (PS-60)
- Class 6 External PSU (100V -240V AC 50Hz-60Hz)
Inputs
- 1 X Line XLR or 3.81mm Euro-block [optimized for -10dBV to 0dBv]
- 1 X Microphone (12V phantom power via 680Ω) [optimised for levels above -45dBv]
Output Characteristics
- Output Voltage : 15Vrms (42.3Vpk-pk) @ 5Arms (14.14Apk-pk) see notes 1 and 2
- Output Current : 5Arms (14.14Apk-pk) up to 300 seconds
- Loop Connector : 5.08mm Euro-block
Audio system
- Frequency Response : 80Hz to 9kHz
- Distortion : THD+N <1% (-40dB)
- AGC : Peak detecting
- HF Comp : 7 optimized stages
- Audio Delay : 1ms – 70ms in 1ms steps
- High Pass Filter : Off/150Hz/180Hz
Note 1: Z=3Ω (265.4uH + 1.37Ω @ 1.6KHz), Note 2: 1% (-40dB) distortion
Display & Control
- Display: LED Backlit LCD
- Control: Single rotary control
Fault Monitoring and Protection
- Main Display: Open circuit loop (DCR measurement)
Loop ground fault
- Front Panel LED : Output voltage clipping
- Cooling: Internal heatsinks with thermal protection
Physical
- Height: 42mm (1.65”)
- Depth: 132mm (5.20”) [150mm (5.90”) including XLR and control knob]
- Width: 198mm (7.80”)
- Weight: 938g (2.06lbs)
V15a+:
Power
- 2.1mm 100W 24Vdc 4.17A via External PSU (PS-60)
- Class 6 External PSU (100V -240V AC 50Hz-60Hz)
Inputs
- 1 X Line XLR or 3.81mm Euro-block [optimised for -10dBV to 0dBv]
- 1 X Microphone (12V phantom power via 680Ω) [optimised for levels above -45dBv]
Output Characteristics
- Output Voltage : 15Vrms (42.3Vpk-pk) @ 5Arms (14.14Apk-pk) see notes 1 and 2
- Output Current: 5Arms (14.14Apk-pk) up to 300 seconds
- Loop Connector: 5.08mm Euro-block
Audio system
- Frequency Response: 80Hz to 9kHz
- Distortion : THD+N <0.3% (-50.5dB) Full current both outputs driven
- AGC : Peak detecting
- HF Comp : 7 optimised stages
- Audio Delay : 1ms – 70ms in 1ms steps
- High Pass Filter : Off/150Hz/180Hz
Note 1: Z=3Ω (265.4uH + 1.37Ω @ 1.6KHz), Note 2: 1% (-40dB) distortion
Display & Control
- Display: LED Backlit LCD display
- Control: Single rotary control
Fault Monitoring and Protection
- Main Display : Open circuit loop (DCR measurement)
Loop ground fault
- Front Panel LED : Output voltage clipping
- Cooling : Internal heatsinks with thermal protection
Physical
- Height: 42mm (1.65”)
- Depth: 132mm (5.20”) [150mm (5.90”) including XLR and control knob]
- Width: 198mm (7.80”)
- Weight: 978g (2.15lbs)
Standards
EMC
- BS EN 55103-1: 2009 (EMC emissions)
- BS EN 55103-2: 2009 (EMC immunity)
This product has been designed and tested to comply with the following North American and Canadian standards:
- FCC class “B” EMC (emissions)
- ICES-003
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
CAUTION: Changes or modifications not expressly approved by Contacta Systems LTD or an authorised partner could void the user’s authority to operate the equipment.
Correct disposal of this product
This marking indicates that this product should not be disposed with other
household waste throughout the EU. To prevent possible harm to the environment
or human health from uncontrolled waste disposal and to conserve material
resources, this product should be recycled responsibly. To dispose of your
product, please use your local return and collection systems or contact the
retailer where the product was purchased.
- UK & ROW
- +44 (0) 1732 223900
- sales@contacta.co.uk
- US & Canada
- +1 616 392 3400
- info@contactainc.com
Contacta Systems Ltd. Office 13, Dana Trading Estate Transfesa Road Paddock Wood, Tonbridge TN12 6UT www.contacta.co.uk