MODERN FORMS PD-80048 LED Pendant Light Instruction Manual

June 9, 2024
MODERN FORMS

MODERN FORMS PD-80048 LED Pendant Light

MODERN-FORMS-PD-80048-LED-Pendant-Light-product

CAUTION:
To prevent electrical shock, ensure electricity has been turned off at the circuit breaker before beginning.

  • Read all instructions before installing.
  • The system is intended for installation by a licensed electrician in accordance with the National Electrical Code (NEC) and local regulations.
  • When handling the fixture, do not apply pressure to the LEDs. Hold the fixture by the base only.
  • Retain installation instructions for future maintenance reference.

WARNING:
All parts must be used as indicated in these instructions. This product is designed for use only with the supplied parts and/or accessories designated for use by Modern Forms. Substitution of parts or accessories not designated for use with this product by Modern Forms could result in personal injury or property damage and will void the warranty. Contact an authorized dealer or manufacturer if any parts are damaged or missing.

MAINTENANCE NOTE

Coastal conditions may cause mineral and residue build-up on the fixture. We recommend that customers in coastal areas clean all external surfaces of the fixture once every two weeks with a wet cloth.

HARDWARE

MODERN-FORMS-PD-80048-LED-Pendant-Light-fig- \(1\)

PREPARATION

  1. Shut off the power at the circuit breaker and remove the existing fixture, including the crossbar.
  2. Carefully unpack your new fixture and lay out all the parts on a clear area. Be careful not to lose any small parts necessary for installation

MOUNTING THE FIXTURE

(Fig. 1)

  1. Remove the mounting screw (B) from the mounting back plate.MODERN-FORMS-PD-80048-LED-Pendant-Light-fig- \(2\)

  2. Center the mounting back plate around the junction box. Drill holes in the ceiling aligned with the keyholes in the mounting plate. Insert the plastic anchor (D)

  3. Secure the mounting back plate to the junction box using the standard junction box screw provided with the junction box. Fasten it to the wall using a wood screw(C) onto the plastic anchor(D). Hook the safety cord to the mounting back plate.
    Note:

  4. Using any other non-original-manufacturer-provided junction box screw may result in safety issues;

  5. The side of the mounting plate marked “GND” must face out.

  6. Adjust the fixture wire length by pushing the cable gripper on the canopy and pulling the wire as desired.

    • Retract the wires close to a desirable length within the canopy before securing the fixture in place.
      Note: retracting or extending excessive cable length through the cable gripper is not recommended.

    • Warning: Shortening these cables without professional help or electronic background is not advisable. Any modifications to the fixture may result in voiding the warranty of the product.

  7. Please follow these if shortening the wire is needed. Take note or take picture of how the wires are being connected and label each wire clearly Using Fig4 and Fig.5 as given below as reference.

CONNECTING THE WIRES

(Fig. 2/Fig. 3)

  1. Connect the driver’s output wires to the center cable as shown in Fig. 3, red to the center, and black to the bare, make sure that wire connectors (A) are secured. Then tuck them inside the canopy.
  2. Connect the driver’s input wires to junction box wires as shown in Fig. 2, and make sure that all wire connectors (A) are secured.

If your outlet box has a green or bare copper ground wire, connect the fixture’s ground wire to it. Otherwise, connect the fixture’s ground wire directly to the back plate using the screw provided. After the wires are connected, tuck them carefully inside the junction box.

DIMMING WIRING INFORMATION

(Fig. 3)

  1. This fixture features electronic low voltage (ELV or TRAIC) or 0-10V dimming capabilities. See notes below for specific dimming wires information.
  2. To utilize ELV or TRAIC dimming: use black (hot), white (neutral), and bare copper ground wires (ground).
  3. To utilize 0-10V dimming: use purple (dim+), gray (dim-), black (hot), white (neutral), and bare copper ground wires (ground).
    NOTE: Make sure to connect 0-10V prior to power-up the fixture in order to allow the 0-10V dimming to function properly.

COMPLETING THE INSTALLATION

  1. Secure the fixture to the mounting back plate using the mounting screw (B).MODERN-FORMS-PD-80048-LED-Pendant-Light-fig- \(6\) MODERN-FORMS-PD-80048-LED-Pendant-Light-fig- \(7\)

modernforms.com
Phone (800) 526.2588
Fax (800) 526.2585.

Headquarters/Eastern Distribution Center
44 Harbor Park Drive Port Washington, NY 11050

Central Distribution Center
1600 Distribution Ct Lithia Springs, GA 30122.

Western Distribution Center
1750 Archibald Avenue
Ontario, CA 91760.

Modern Forms retains the right to modify the design of our products at any time as part of the company’s continuous improvement program. Nov. 2020.

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals