IMPORTANT SAFETY INSTRUCTIONS

READ AND SAVE THESE INSTRUCTIONS BEFORE YOU START INSTALLING THIS RANGE HOOD
WARNING: – TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE:

  • a) Never leave surface units unattended at high settings. Boilovers cause smoking and greasy spillovers that may ignite. Heat oils slowly on low or medium setting.
    b) Always turn hood ON when cooking at high heat or when flambeing food (i.e. CrepesSuzette, Cherries Jubilee, Peppercorn Beef Flambé).
    c) Clean ventilating fans frequently. Grease should not be allowed to accumulate on fan or filter.
    d) Use proper pan size. Always use cookware appropriate for the size of the surface element.

WARNING: – TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A RANGETOP GREASE FIRE, OBSERVE THE FOLLOWING*:

  • a) SMOTHER FLAMES with a close-fitting lid, cookie sheet, or metal tray, then turn off the burner. BE CAREFUL TO PREVENT BURNS. If the flames do not go out immediately evacuate AND CALL THE FIRE DEPARTMENT.

  • b) NEVER PICK UP A FLAMING PAN – You may be burned.

  • c) DO NOT USE WATER, including wet dishcloths or towels – a violent steam explosion will result.

  • d) Use an extinguisher ONLY if:

    • You know you have a Class ABC extinguisher, and you already know how to operate it.
    • The fire is small and contained in the area where it started.
    • The fire department is being called.
    • You can fight the fire with your back to an exit.
  • Based on “Kitchen Fire safety Tips” published by NFPA
    WARNING – TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, do not use this fan with any solid-state speed control device.
    WARNING – TO REDUCE THE RISK OF FIRE, ELECTRICAL SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:

  1. Use this unit only in the manner intended by the manufacturer. If you have any questions, contact the manufacturer.
  2. Before servicing or cleaning unit, switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.

CAUTION: For General Ventilating Use Only. Do Not Use To Exhaust Hazardous or Explosive Materials and Vapors.
WARNING – TO REDUCE THE RISK OF FIRE, ELECTRICAL SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:

  1. Installation Work And Electrical Wiring Must Be Done By Qualified Person(s) In Accordance With All Applicable Codes And Standards, Including Fire-Rated Construction.
  2. Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel-burning equipment to prevent back-drafting. Follow the heating equipment manufacturer’s guidelines and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities.
  3. When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.
  4. Ducted fans must always be vented to the outdoors.

ALL WALL AND FLOOR OPENINGS WHERE THE RANGE HOOD IS INSTALLED MUST BE SEALED.
This Range Hood requires at least 24″ of clearance between the bottom of the Range Hood and the cooking surface or countertop. This hood has been approved by UL at this distance from the cooktop. This minimum clearance may be higher depending on local building codes. For gas cooktops and combination ranges, a minimum of 30″ is recommended and may be required. Overhead cabinets on both sides of this unit must be a minimum of 18″ above the cooking surface or countertop. Consult the cooktop or range installation instructions given by the manufacturer before making any cutouts.

MOBILE HOME INSTALLATION The installation of this Range Hood must conform to the Manufactured Home Construction and Safety Standards, Title 24 CFR, Part 3280 (formerly Federal Standard for Mobile Home Construction and Safety, Title 24, HUD, Part 280). See Electrical Requirements”

VENTING REQUIREMENTS
Determine which venting method is best for your application. Ductwork can extend either through the wall or the roof. The length of the ductwork and the number of elbows should be kept to a minimum to provide efficient performance. The size of the ductwork should be uniform. Do not install two elbows together. Use duct tape to seal all joints in the ductwork system. Use caulking to seal exterior wall or floor opening around the cap. Flexible ductwork is not recommended. Flexible ductwork creates back pressure and air turbulence that greatly reduces performance. Make sure there is proper clearance within the wall or floor for exhaust duct before making cutouts. Do not cut a joist or stud unless absolutely necessary. If a joist or stud must be cut, then a supporting frame must be constructed.

WARNING – To Reduce The Risk Of Fire, Use Only Metal Ductwork.
CAUTION – To reduce risk of fire and to properly exhaust air, be sure to duct air outside – Do not vent exhaust air into spaces within walls or ceilings or into attics, crawl spaces, or garages.

Cold Weather installations
An additional back draft damper should be installed to minimize backward cold air flow and a nonme-tallic thermal break should be installed to minimize conduction of outside temperatures as part of the vent system. The damper should be on the cold air side of the thermal break. The break should be as close as possible to where the vent system enters the heated portion of the house.

WARNING

  • Venting system MUST terminate outside the home.
  • DO NOT terminate the ductwork in an attic or other enclosed space.
  • DO NOT use 4″ laundry-type wall caps.
  • Flexible-type ductwork is not recommended.
  • DO NOT obstruct the flow of combustion and ventilation air.
  • Failure to follow venting requirements may result in a fire.

ELECTRICAL REQUIREMENTS
A 120 volt, 60 Hz AC-only electrical supply is required on a separate 15 amp fused circuit. A time-delay fuse or circuit breaker is recommended. The fuse must be sized per local codes in accordance with the electrical rating of this unit as specified on the serial/rating plate located inside the unit near the field wiring compartment.

WARNING

  • Electrical ground is required on this Range Hood.
  • If cold water pipe is interrupted by plastic, non-metallic gaskets or other materials, DO NOT use for grounding.
  • DO NOT ground to a gas pipe.
  • DO NOT have a fuse in the neutral or grounding circuit. A fuse in the neutral or grounding circuit could result in electrical shock.
  • Check with a qualified electrician if you are in doubt as to whether the Range Hood is properly grounded.
  • Failure to follow electrical requirements may result in a fire.

RANGE HOOD DIMENSIONS

CLPL30SSV2-Classica-Plus-30-Inch-Stainless-Steel-Wall-Mounted-Range-Hood-
\(1\)

INSTALLATION HEIGHT REQUIREMENTS

CLPL30SSV2-Classica-Plus-30-Inch-Stainless-Steel-Wall-Mounted-Range-Hood-
\(2\)

PARTS

PARTS INCLUDED

REF.| PART|
---|---|---
A| Hood body – Includes Controls, Light, Filters, Blower| 1
B| Damper| 1
C| Lower Chimney| 1
D| Upper Chimney| 1
E| Chimney wall brackets| 2

CLPL30SSV2-Classica-Plus-30-Inch-Stainless-Steel-Wall-Mounted-Range-Hood-
\(3\)

PARTS NEEDED

CLPL30SSV2-Classica-Plus-30-Inch-Stainless-Steel-Wall-Mounted-Range-Hood-
\(4\)

ACCESSORIES AVAILABLE

ACCESSORY SKU#
DUCTLESS KIT CLAS (DIVERTER + CHARCOAL) DUCTCLPL
CHARCOAL FILTER KIT FILTER1
CHARCOAL FILTER KIT WASHABLE LONG LASTING FILTER1LL2
HIGH CEILING KIT HIGHCLPL
REMOTE CONTROL REMORIG
FIXED WIRING BOX WIREBOX

TOOLS NEEDED

CLPL30SSV2-Classica-Plus-30-Inch-Stainless-Steel-Wall-Mounted-Range-Hood-
\(5\)

DUCTED VENTING METHOD OPTIONS

DUCTED WITH 7″ ROUND OUTLET:

  • Vertical
  • Horizontal

NON-DUCTED – RECIRCULATION OPTION
Requires purchase of Activated Charcoal Accessory

MOUNTING RANGE HOOD ON WALL

  1. DRAW POSITIONING LINES
    Draw a vertical line H from the supporting back wall to the ceiling or upper limit, at the center of the area in which the hood will be installed. Draw a horizontal line I from where the bottom edge of the hood will be located, to a minimum of 24″ above an electric cooking surface and 30″ above a gas cooking surface.CLPL30SSV2-Classica-Plus-30-Inch-Stainless-Steel-Wall-Mounted-Range-
Hood- \(8\)

  2. Draw a horizontal line where indicated at the bottom edge of the vent hood at the desired height above the cooking surface. Place a bracket E on the wall as shown about 1/8″ from the ceiling or upper limit, aligning the centers(notch) with the vertical reference line and mark the wall at the centers of the holes in the bracket. Place the second bracket E on the wall as shown, below the first bracket, at the height of the upper chimney section D supplied and aligning the centers(notch) with the vertical line. Mark the wall at the centers of the holes in the bracket and mark the point 1 and 2 for the Hood Body installation as show (7 1/16″ from the horizontal line and 5 1/2″ from the vertical line). Drill ø 5/16″ holes at all the centers points marked (point 1,2,3,4,5,6) as shown.CLPL30SSV2-Classica-Plus-30-Inch-Stainless-Steel-Wall-Mounted-Range-Hood- \(9\)
    MOUNTING THE RANGE HOOD

  3. Install wall plugs if needed (purchase separately). Partially insert the two screws supplied F , into the wall as shown onto holes 1 and 2.CLPL30SSV2-Classica-Plus-30-Inch-Stainless-Steel-Wall-Mounted-Range-Hood- \(10\)

  4. Hang the hood on the wall by pushing the screws through the 2 designated key holes on the back of the hood. Tighten the screws.

  5. From inside the hood, mark the holes for the two security holes, drill a 5/16″ x 2 where marked. Insert 2 wall plugs into the holes and tightly screw 2 screws F.CLPL30SSV2-Classica-Plus-30-Inch-Stainless-Steel-Wall-Mounted-Range-Hood- \(12\)

  6. Vertical or Horizontal Ducting Installation
    Install Damper B that is included with the Hood before connecting to the ductwork. Install Roof or Wall Cap purchased separately. Connect the 6″ metal ductwork to the Roof or Wall Cap and then attach ductwork.

  7. Attach the 2 chimney brackets E using 4 screws F supplied.

  8. Slightly widen the two sides of the upper chimney D and hook them behind the brackets E making sure that they are well seated.

  9. Secure the sides to the brackets E by using the 4 screws G.

  10. Slightly widen the two sides of the lower chimney and hook them between the upper section and the wall, making sure that they are properly housed.
    NON-DUCTED RECIRCULATION OPTION

  11. Non-Ducted Recirculation Option
    Only for the recirculation version, connect the ductless diverter onto the top of the hood body. (purchased separately)

  12. Attach each charcoal filter to the black grid on each side of the blower. Press the charcoal filter tightly to the black grid on the blower side and rotate the filter clockwise (towards the front of the hood) until it locks into place. Turn counterclockwise (towards the back of the hood) to remove.

CONNECTING ELECTRICITY

ELECTRICAL INSTALLATION WITH CONNECTION CABLE
GROUNDING INSTRUCTIONS This appliance must be grounded. In the event of an electrical short circuit, grounding reduces the risk of electric shock by providing an escape wire for the electric current. This appliance is equipped with a cord having a grounding wire with a grounding plug. The plug must be plugged into an outlet that is properly installed and grounded.
WARNING – Improper grounding can result in a risk of electric shock. Consult a qualified electrician if the grounding instructions are not completely understood, or if doubt exists as to whether the appliance is properly grounded. Do not use an extension cord. If the power supply cord is too short, have a qualified electrician install an outlet near the appliance.

ELECTRICAL INSTALLATION WITH OPTIONAL WIRING BOX
For Permanent wiring Installation-Use only with Listed rangehood Wiring Box kit sku # WIREBOX, manufactured by Faber.CLPL30SSV2-Classica-Plus-30-Inch-
Stainless-Steel-Wall-Mounted-Range-Hood- \(22\)

OPERATING THE CONTROLS

FOR BEST RESULTS
Start the Range Hood several minutes before cooking to develop proper airflow. Allow the Range Hood to operate for several minutes after cooking is complete to clear all smoke and odors from the kitchen.

NOTE: If your product has had a CFM adjustment, refer to the CFM adjustment manual for the information. Some motor speeds or functions may be reduced.

CARING FOR FILTERS

CLEANING METAL GREASE FILTERS
The metal grease filters can be cleaned in hot detergent solution or washed in the dishwasher. They should be cleaned every 2 months use, or more frequently if use is particularly heavy.

  1. Remove the filter, pushing the lever towards the back of the unit while pulling downward.
  2. Wash the filter without bending it. Leave it to dry thoroughly before replacing. If the surface of the filter changes color over time, efficiency will not be affected.
  3. To replace the filter, push the filter up into position while holding the lever back, then release lever to lock in place.

NOTES:

  • Cleaning in a dishwasher may dull the finish of the metal grease filters.
  • Ensure that the filters are completely dry before installing them back into the Range Hood.

CLEANING EXTERIOR SURFACES
Please note, abrasives and scouring agents can scratch range hood finishes and should not be used to clean finished surfaces. Stainless Steel finish cleaning instructions: Clean exterior surfaces with a commercially available stainless steel cleaner.

REPLACING ACTIVATED CHARCOAL FILTER
The Activated Charcoal Filters are not washable and cannot be regenerated, and must be replaced approximately every 4 months of operation, or more frequently with heavy usage.

  1. Remove the grease filters.
  2. Remove the saturated charcoal filter by rotating it clockwise ( backwards) until it unlocks from the motor housing and pull off sideways.
  3. To re-insert each charcoal filter, place up against the side of the blower and push it inward. Then turn the charcoal filter clockwise (forward) until it fits into place.

REPLACING LIGHTING
LED lights must be replaced by Faber factory authorized service.

WIRING DIAGRAM

CLPL30SSV2-Classica-Plus-30-Inch-Stainless-Steel-Wall-Mounted-Range-Hood-
\(27\)

WARRANTY

Franke Home Solutions Warranty for Franke and Faber Branded Product Effective March 1, 2022

In the United States, Canada and Latin America, Franke warrants the Faber branded products from manufacturing defects in material and workmanship when purchased from a Franke or Faber Authorized Retailer pursuant to product- specific warranties detailed herein (each, a “Warranty” and collectively, the “Warranties”). The products must be properly installed, per Franke’s installation instructions, in their original installation, and used in normal indoor residential kitchen applications. Any products or components which have been modified or altered from their original intended condition will void the Warranty. The Franke Warranties for Faber branded products are limited to the original purchaser and are non-transferrable. These Warranties do not include products purchased from non-Authorized Retailers, products that are obsolete or discontinued, or products that were previous display models. All issues with installed products are considered warranty claims and not subject to the Return Policy. Franke reserves the right to inspect any Franke / Faber product reported to be defective pursuant to a Warranty claim and the original installation prior to providing a replacement product and/or component. All decisions are final. In no situation shall the liability of Franke exceed the amount of the original purchase price.

The Warranties do not cover, and Franke shall not be liable for, any damage to products or components resulting from misuse or abuse, accidental damages, normal wear such as scuffs, scratches or finish reduction/fading, improper installation, abnormal usage, negligence, damage caused by improper maintenance or cleaning. Damage caused by impurities, corrosive chemicals or acts beyond Franke’s control are not covered by any Warranty. Service calls to correct the installation of a range hood, instructions on how to operate a range hood, to replace or repair house fuses or to correct house wiring or plumbing are not covered by any Warranty. Service calls to repair or replace range hood light bulbs, fuses or filters and these consumable part costs are also excluded from Warranty coverage.

Installation not in accordance with electrical or plumbing codes or Franke / Faber documentation are not covered by any Warranty. Replacement parts or repair labor costs for units operated outside the United States, Canada or Latin America, including any non-UL or C-UL or non-NOM approved Franke / Faber range hoods are excluded from Warranty coverage. Expenses for travel and transportation for service in remote locations and pickup and delivery charges are not covered by any Warranty. Franke / Faber range hoods should always be serviced in the home in their original installation.
Franke / Faber product replacements do not include liability for project delays. Product replacements are not guaranteed to be exact replacements. If the original product is not available at the time of the warranty claim, at Franke’s option, the product replacements will be of similar size, material, and value. Any products or components which have been modified or altered, from its original intended condition will void the warranty.

The Warranties do not allow recovery of incidental or consequential damages such as loss of use, delay, property damage or other consequential damage, and Franke accepts no liability for such damages. Each Warranty is limited to the conditions set forth herein and to the applicable warranty period specified herein and is exclusive.

EXCEPT FOR THE WARRANTIES SET FORTH HEREIN, FRANKE MAKES NO WARRANTY WHATSOEVER WITH RESPECT TO THE PRODUCTS, INCLUDING, BUT NOT LIMITED TO, (1) ANY WARRANTY OF MERCHANTABILITY, (2) WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE, (3) WARRANTY OF TITLE, OR (4) WARRANTY AGAINST INFRINGEMENT OF INTELLECTUAL PROPERTY RIGHTS OF A THIRD PARTY, WHETHER EXPRESS OR IMPLIED BY LAW, COURSE OF DEALING, COURSE OF PERFORMANCE, USAGE OF TRADE OR OTHERWISE. LEGAL DISCLAIMER PLEASE
READ CAREFULLY. Franke Kitchen Systems LLC provides the above information to you as a public service to our customers. By accessing and using this information, you agree to the following and to comply with all applicable laws. If you do not agree with these terms and conditions, do not use this information. While we try to keep the information current, changes may have occurred since its creation. Contact your Regional Manager or Customer Service to verify information regarding Franke Kitchen Systems LLC programs and their use by you.

Franke / Faber Range Hood Limited Warranty:
Franke / Faber range hoods are warranted against any defect in materials or workmanship for the original purchaser for a period of two (2) years from the date of original purchase when used in standard residential indoor applications. This warranty covers labor and replacement parts. Franke, at its option, may repair or replace the product or components necessary to restore the product to good working condition.

This warranty supersedes all other warranties, expressed or implied. No employee, field sales representatives, or distribution persons are authorized to give any warranties on behalf of Franke Kitchen Systems, LLC.

To make an installed product warranty claim please contact Franke at the provided contact information below. All warranty claims must include the following for processing:

  1. Proof of purchase from Franke or Faber Authorized Retailer
  2. Original purchaser’s name, address (including city, state, zip), email address, and phone number
  3. Franke / Faber model and serial number
  4. Date of installation
  5. Description of the defect
  6. Photos of the defect

In North America and Latin America:
Franke Home Solutions
Attn: Warranty Department 800 Aviation Parkway
Smyrna, TN 37167
[email protected]
Legal Entity: Franke Kitchen Systems LLC

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals