amber connect ACT200 Amber Convert T200 GSM-GNSS-BLE Terminal User Guide
- June 9, 2024
- amber connect
Table of Contents
amber connect ACT200 Amber Convert T200 GSM-GNSS-BLE Terminal
Characteristic
MODULE
Name | ACT200 |
---|---|
Technology | GSM/GPRS/GNSS/BLUETOOT |
GNSS
GNSS | GPS, GLONASS, GALILEO, BEIDOU, SBAS, QZSS, DGPS, AGPS |
---|---|
Receiver | 33 channel |
Tracking sensitivity | -165 dBM |
Accuracy | < 3 m |
Hot start | < 1 s |
Warm start | < 25 s |
Cold start | < 35 s |
Cellular
Technology | GSM |
---|---|
2G bands | Quad-band 850 / 900 / 1800 / 1900 MHz |
Data transfer | GPRS Multi-Slot Class 12 (up to 240 kbps), GPRS Mobile Station |
Class B
Data support| SMS (text/data)
POWER
Input voltage range | 10-30 V DC with overvoltage protection |
---|---|
Back-up battery | 170 mAh Li-Ion battery 3.7 V (0.63 Wh) |
Internal fuse | 3 A, 125 V |
Power consumption | At 12V < 6 mA ([Ultra Deep |
Sleep](https://wiki.teltonika.lt/index.php?title=FMB120_Sleep_modes&Ultra_Deep_Sleep_mode))
At 12V < 8 mA (Deep
Sleep)
At 12V < 11 mA (Online
Sleep)
At 12V < 20 mA (GPS
Sleep)
At 12V < 35 mA (nominal with no load) At 12V < 1.5 A Max. (with full
Load/Peak)
BLUETOOTH
Specification | 4.0 + LE |
---|---|
Supported peripherals | [Temperature and Humidity sensor, |
](https://teltonika.lt/product/bluetooth-sensor/)[Headset, ](https://wiki.teltonika.lt/view/How_to_connect_Blue- tooth_Hands_Free_adapter_to_FMB_device)OBDII dongle, Inateck Barcode Scanner, Universal BLE sensors support
INTERFACE
Digital Inputs | 3 |
---|---|
Digital Outputs | 2 |
Analog Inputs | 2 |
CAN Adapter inputs | 1 |
1-Wire | 1 |
GNSS antenna | Internal High Gain |
GSM antenna | Internal High Gain |
USB | 2.0 Micro-USB |
LED indication | 2 status LED lights |
Memory | 128MB internal flash memory |
PHYSICAL SPECIFICATION
Dimensions | 65 x 56,6 x 20,6 mm (L x W x H) |
---|---|
Weight | 55 g |
OPERATING ENVIRONMENT
Operating temperature (without battery) | -40 °C to +85 °C |
---|---|
Storage temperature (without battery) | -40 °C to +85 °C |
Operating humidity | 5% to 95% non-condensing |
Ingress Protection Rating | IP41 |
Battery charge temperature | 0 °C to +45 °C |
Battery discharge temperature | -20 °C to +60 °C |
Battery storage temperature | -20 °C to +45 °C for 1 month |
-20 °C to +35 °C for 6 months
FEATURES
Sensors | Accelerometer |
---|---|
Scenarios | Green Driving, [Over Speeding detection, |
](https://wiki.teltonika.lt/index.php?title=FMB120_Features_settings&Over_Speeding)[Jamming
detection,
](https://wiki.teltonika.lt/index.php?title=FMB120_Features_settings&Jamming)[GNSS](https://wiki.teltonika.lt/index.php?title=FMB120_Features_settings&Jamming)
Fuel Counter,
DOUT
Control Via Call,
Excessive
Idling
detection,
Immobilizer,
iButton
Read
Notification,
Unplug
detection,
Towing
detection,
Crash
detection,
Auto
Geofence,
Manual
Geo fence,
Trip
Sleep modes| GPS Sleep,
Online
Deep Sleep,
Deep
Sleep,
Ultra
Deep
Sleep
SMS| Configuration, Events, DOUT control, Debug
GPRS commands| Configuration, DOUT control, Debug
Time Synchronization| GPS, NITZ, NTP
Fuel monitoring| LLS (Analog), LV-CAN200, ALL-CAN300, OBDII
dongle,
CAN-
CONTROL
Ignition detection| Digital Input 1, Accelerometer, External Power Voltage,
Engine RPM (CAN Adapters, OBDII dongle)
ACCESSORIES
Bluetooth and analog fuel sensor
RFID reader
Temperature sensor
-
Bluetooth fuel sensor
-
Analog fuel sensor
-
RFID reader
-
Wired temperature sensor
Electrical characteristics
CHARACTERISTIC DESCRIPTION | VALUE **** |
---|---|
MIN. | TYP. |
SUPPLY VOLTAGE
Supply Voltage (Recommended Operating Conditions) | +10 | +30 | V |
---|
DIGITAL OUTPUT (OPEN DRAINGRADE)
Drain current (Digital Output OFF) | 120 | µA | ||
---|---|---|---|---|
Drain current (Digital Output ON, Recommended Operating Conditions) | 0.1 | |||
0.5 | A | |||
Static Drain-Source resistance (Digital Output ON) | 400 | 600 | mΩ |
DIGITAL INPUT
Input resistance (DIN1) | 47 | kΩ | ||
---|---|---|---|---|
Input resistance (DIN2) | 51.7 | kΩ | ||
Input resistance (DIN3) | 150 | kΩ | ||
Input voltage (Recommended Operating Conditions) | 0 | Supply voltage | V | |
Input Voltage threshold (DIN1) | 7.5 | V | ||
Input Voltage threshold (DIN2) | 2.5 | V | ||
Input Voltage threshold (DIN3) | 2.5 | V |
ANALOG INPUT
Input voltage (Recommended Operating Conditions), Range 1 | 0 | +10 | V | |
---|---|---|---|---|
Input resistance, Range 1 | 38.45 | kΩ | ||
Measurement error on 12V, Range 1 | 0.9 | % | ||
Additional error on 12 V, Range 1 | 108 | mV | ||
Measurement error on 30 V, Range 1 | 0.33 | % | ||
Additional error on 30 V, Range 1 | 88 | mV | ||
Input Voltage (Recommended Operating Conditions), Range 2 | 0 | +30 | V | |
Input resistance, Range 2 | 150 | kΩ | ||
Measurement error on 12 V, Range 2 | 0.9 | % | ||
Additional error on 12 V, Range 2 | 108 | mV | ||
Measurement error on 30 V, Range 2 | 0.33 | % | ||
Additional error on 30 V, Range 2 | 88 | mV |
OUTPUT SUPPLY VOLTAGE 1-WIRE
Supply voltage | +4.5 | +4.7 | V | |
---|---|---|---|---|
Output inner resistance | 7 | Ω | ||
Output current (Uout > 3.0 V) | 30 | mA | ||
Short circuit current (Uout = 0) | 75 | mA |
Pinout
PIN NUMBER | PIN NAME | DESCRIPTION |
---|---|---|
1 | VCC (10-30) V DC (+) | Power supply (+10-30 V DC). |
2 | AIN 1 | Analog input, channel 1. Input range: 0-30 V DC. |
3 | AIN 2 / DIN 3 | Analog input, channel 2. Input range: 0-30 V DC / Digital |
input, channel 3.
4| DIN 2| Digital input, channel 2.
5| DIN 1| Digital input, channel 1.
6| INPUT 6| TX EXT (LVCAN – TX).
7| GND (-)| Ground pin. (10-30) V DC (―)
8| DOUT 1| Digital output, channel 1. Open collector output. Max. 0,5 A DC
9| DOUT 2| Digital output, channel 2. Open collector output. Max. 0,5 A DC
10| 1WIRE POWER| +3,8 V output for 1–Wire devices.
11| 1WIRE DATA| Data for 1–Wire devices.
12| INPUT 5| RX EXT (LVCAN – RX).
Accessories Connection Possibilities
- 4 IN ports/pin
- 2 Digital
- 1 Analog
- 1 Digital or Analog
- 2 OUT ports/pins
- 2 Digital (for future use)
- 1 One-wire connection
Installation team must follow the below Accessory connection for efficient working. If installation has to be done with different patterns then please contact your immediate tech support for the possibilities. You can configure these accessories settings in our amber connect fleet management platform. Fleet Portal > Settings > Vehicle > Safety > Device Input Configuration [This setting available Only to specific device models that supports the accessories]
Warning: These settings should exactly match with the actual accessories connected to the device ports during the installation. If you make any changes on this will result in data reception from accessories to the device. So Kindly make sure you are changing this with proper understanding of which accessory connected to which wire during the installation.
Wiring Scheme
Mounting Recommendations
-
Connecting wires
a) Wires should be connected while the module is not plugged in.
b) Wires should be fastened to stable wires or other non-moving parts. Any heat emitting and/or moving objects should be kept away from the wires.
c) There should be no exposed wires. If factory isolation was removed while connecting the wires, the isolation material should be applied.
d) If the wires are placed in the exterior or in places where they can be damaged or exposed to heat, humidity, dirt, etc., additional isolation should be applied and the wires should not be loose.
e) Wires cannot be connected to the board computers or control units. -
Connecting power source
a) Be sure that after the car computer goes to sleep mode, power might be still available on the power wires. Depending on the car model, this may happen in 5 to 30 minutes period.
b) When the module is connected, measure the voltage again to make sure it did not decrease.
c) It is recommended to connect to the main power cable in the fuse box.
d) 3 A, 125 V external fuse shall be used. -
Connecting ignition wire
a) Be sure to check if it is a real ignition wire i. e. power does not disappear after starting the engine.
b) Check if this is not an ACC wire (when key is in the first position, most of the vehicle electronics are available).
c) Check if power is still available when you turn off any of vehicles devices.
d) Ignition is connected to the ignition relay output. As alternative, any other relay, which has power output when ignition is on, may be chosen. -
Connecting ground wire
a) Ground wire is connected to the vehicle frame or metal parts that are fixed to the frame.
b) If the wire is fixed with the bolt, the loop must be connected to the end of the wire.
c) For better contact scrub paint from the spot where loop is going to be connected.
LED Indications
BEHAVIOUR | MEANING |
---|---|
Permanently switched on | GNSS signal is not received |
Blinking every second | Normal mode, GNSS is working |
Off | GNSS is turned off because: Device is not working or Device is in Sleep |
mode
Blinking fast constantly| Device firmware is being flashed
BEHAVIOUR| MEANING
---|---
Blinking every second| Normal mode
Blinking every two seconds| Sleep mode
Blinking fast for a short time| Modem activity
Off| Device is not working or Device is in Boot mode
Safety information
This message contains information on how to operate safely. By following these requirements and recommendations, you will avoid dangerous situations. You must read these instructions carefully and follow them strictly before operating the device!
- The device uses SELV limited power source. The nominal voltage is+12 V DC. The allowed voltage range is +10…+30 V DC.
- To avoid mechanical damage, it is advised to transport the device in an impact-proof package. Before usage, the device should be placed so that its LED indicators are visible. They show the status of device operation.
- When connecting the 2×6 connector wires to the vehicle, the appropriate jumpers of the vehicle power supply should be disconnected.
- Before unmounting the device from the vehicle, the 2×6 connector must be disconnected. The device is designed to be mounted in a zone of limited access, which is inaccessible to the operator. All related devices must meet the requirements of EN 62368-1 standard. The device is not designed as a navigational device for boats.
| Do not disassemble the device. If the device is damaged, the power supply
cables are not isolated or the isolation is damaged, DO NOT touch the device
before unplugging the power supply.
---|---
| All wireless data transferring devices produce interference that may affect
other devices which are placed nearby.
| The device must be connected only by qualified personnel.
| The device must be firmly fastened in a predefined location.
| The programming must be performed using a PC with autonomic power supply.
| Installation and/or handling during a lightning storm is prohibited.
| The device is susceptible to water and humidity.
| Risk of explosion if battery is replaced by an incorrect type. Dispose of
used batteries according to the instructions.
| Battery should not be disposed of with general household waste. Bring
damaged or worn-out batteries to your local recycling center or dispose them
to battery recycle bin found in stores.
Certification and Approvals
- EAC
- REACH
- Declaration of IMEI assignment
- CE / RED
- E-Mark
- RoHS
- Declaration of device operation temperature
| This sign on the
package means that it is necessary to read the User Manual before your start
using the device.
---|---
| This sign on the package means that all used electronic and electric
equipment should not be mixed with general household waste.
| Hereby, we declare under our sole responsibility that the above described
product is in conformity with the relevant Community harmonization: European
Directive 2014/53/EU (RED).
Need help? Contact 2L,/7 live support!
ln App Chat
support@amberconnect.com
Chat via website www.omberconnect.com
Works with Android phones and tablets, iPhone, iPad.
Compatible with Chrome, !Mac and PC web browsers.
Amber Connect
@2022 Amber Connect Limited. All rights reserved
Scan this QR code to download your App
References
- Teltonika - IoT, Internet of Things
- Teltonika - IoT, Internet of Things
- Teltonika - IoT, Internet of Things
- Teltonika - IoT, Internet of Things
- Teltonika - IoT, Internet of Things
- Teltonika - IoT, Internet of Things
- Teltonika - IoT, Internet of Things
- Teltonika - IoT, Internet of Things
- Teltonika - IoT, Internet of Things
- Teltonika - IoT, Internet of Things
- Teltonika - IoT, Internet of Things
- Teltonika - IoT, Internet of Things
- Teltonika - IoT, Internet of Things
- FMB120 CE / RED - Wiki Knowledge Base | Teltonika GPS
- FMB120 Declaration of device operation temperature - Wiki Knowledge Base | Teltonika GPS
- FMB120 E-Mark - Wiki Knowledge Base | Teltonika GPS
- FMB120 RoHS - Wiki Knowledge Base | Teltonika GPS
- How to connect Bluetooth® Hands Free adapter to FMB device - Wiki Knowledge Base | Teltonika GPS
- How to connect OBD II Bluetooth Dongle to FMB device - Wiki Knowledge Base | Teltonika GPS