BD SENSORS DPS 200 Differential Pressure Transmitter for Gas and Compressed Air Instruction Manual

June 9, 2024
BD SENSORS

BD SENSORS DPS 200 Differential Pressure Transmitter for Gas and Compressed Air Instruction Manual
BD SENSORS DPS 200 Differential Pressure Transmitter for Gas and Compressed
Air

WARNING – In order to avoid hazards to operators and damages to the device, the following instructions have to be performed by qualified technical personnel.
WARNING – Adhere to the safety and operating instructions stated in this instructions. Effective regulations on occupational safety, accident prevention as well as national installation standards and approved engineering techniques must in addition be complied with.

Limitation of liability and warranty

Failure to observe the instructions or technical regulations, improper use and use not as intended, and alteration of or damage to the device will result in the forfeiture of warranty and liability claims.

Intended use

Ensure that the medium is compatible with the media-wetted
parts and that the device is suitable for the application without restrictions. BD|SENSORS assumes no liability for any wrong selection and the consequences thereof! The technical data listed in the current data sheet are engaging and must absolutely be complied with.

Product identification

Product identification

Installation

DANGER – Always mount the device in a depressurized and de-energized condition.

Mount the device in a suitable location using the mounting holes. Connections should be vertical, i. e. the pressure connections should point downwards. The sensors are calibrated in the factory for these mounting conditions. In addition, the formation of condensation in the pressure tubing of the sensor is also reduced.

Use the appropriate hoses for the connection. Connect the hose with the higher pressure to the right hand (positive) pressure port and the hose with the lower pressure to the left hand (negative) pressure port.

Electrical installation

DANGER – Always mount the device in a depressurized and de-energized condition.
NOTE – For the cable gland, you have to make sure that the external diameter of the used cable is within the allowed clamping range. Moreover you have to ensure that it lies in the cable gland firmly and cleftlessly.
NOTE – Do not touch the electronics outside the connection terminal.
WARNING – According to the wiring diagram, the connection cables must be fastened to the connection terminals in a professional manner.
WARNING – Before the device is closed, make sure that the connection cables are fixed and will not dissolve.

Wiring diagrams

  • 2-wire-system (current)
    Wiring diagrams

  • 3-wire-system (current/supply)
    Wiring diagrams

Pin configuration

Electrical connections

| Terminals
---|---
2-wire-system| 3-wire-system
supply + supply – signal + (only for 3-wire)| 2 / + 3 / − (not connected)| 2 / VS+ 3 / VS− 1 / SIG

Dimensions (drawing of version with LC-display)

dimensions for version “without display” are identical
Dimensions

**Photo / adjustability (offset / response time)

**

BD SENSORS Logo

Documents / Resources

| BD SENSORS DPS 200 Differential Pressure Transmitter for Gas and Compressed Air [pdf] Instruction Manual
DPS 200, Differential Pressure Transmitter for Gas and Compressed Air, DPS 200 Differential Pressure Transmitter for Gas and Compressed Air, DPS 200 Differential Pressure Transmitter, Differential Pressure Transmitter, Pressure Transmitter, Transmitter
---|---

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals