BECEN BC-P502 LED5IN1/6IN1 LED Par Light User Manual

June 9, 2024
BECEN

LED PAR LIGHT
User’s manual BECEN BC P502 LED5IN1 6IN1 LED Par LightITEM No : LED5IN1/6IN1
Before use please read this manual

BC-P502 LED5IN1/6IN1 LED Par Light

Features:
NO.:-LED-PAR
Colorful color ; automatic / online synchronization ;Strobe mode; multi- channel mode Linear dimming from 0-100% ; DMX512 Console

Safety precautions:

To ensure that the local voltage and the required voltage for product is consistent.
If a product’s power cord is damaged, please do not try to use the product. Do not try to unplug the power cord from the ground plug. Plug is used to reduce short-circuit electric shocks and fire prevention.
Before making any connections disconnect the main power supply.
In any case, please do not remove the lid, which is not part of the user can use.
If the product of the shell is missing, please do not run product.
Do not stuff the products to the dimmer package. Guarantee that the product in the ventilate place ,and maintained between the product and the wall 6 feet (15 cm) distance.
If damaged, please do not run product.
If the long-term non-use products, please disconnect the power.
Make sure the product located in a safe and stable place.
Special attention to the power cord from being pinched or out of product.
Cleaning :
In accordance with the manufacturer’s recommendation to clean products’ fixed position. Please read the “cleaning” in detail.

Heat output

Devices should be away from heat sources such as radiator, heater, warm furnace or other devices generate heat.
In the following circumstances, the fixed installations are required to qualified service personnel overhaul:
A. When the power cord or plug is damaged.
B. The product fall or when the liquid outflow the device.
C. When the device does not work correctly, or have some change in the exhibition.

Installation of power:

At the time of switching in power, make sure that the voltage in your area is consistent with the the led spot light’s voltage. This product for AC110V- 240V. Since different parts of the voltage is different, so products in operation, make sure your wall outlet voltage consistent with the product.

DMX combination:

In order to ensure a fixed DMX data transmission, when using several DMX device to the fullest extent possible use the shortest cables. Fixtures connected to the DMX channel order does not affect the choice of DMX. For example: when the allocation of fixed installations DMX 1 channel, DMX will be located in any location, in the front, back or middle of anywhere. When the fixed installations assigned to DMX 1 channel, whether it is located in which of the DMX channels, DMX controller is aware that the data sent on the first channel .
The operation of using the manual, it have 4keys on the display board:

DIAGRAM:

A. Function
B. Up
C. Down
D. Enter
E. Digital Display

HOW TO OPERATE?
Press button A, there will be eight different effects.
The fist two numeric stands for functions (refer to Diagram II)
The last two numeric stands for DMX address, or speed.
You can modify it with B or C button..
D button is to confirm while you settled.
2. LED Display function cross-references, (D button is to confirm while you settled)

No. Display Function
1 A001 9/10/CHs Address Code , (001— 512)

Change the address code by    B or C button
2| CC00| 8Colors Changing , (01—99)
Color change fast by B or C button
3| CP00| 8colors gradual change , (01—99)
Speed of gradual changing by B or C button
4| DE00| 8 Colors mixed changing , ( 01 — 99)
Select color. While change color, with B or C button
5| BEBE| Music activate
6| R000| Red color Changing , (000—255)
Change the color by B or C button
7| G000| Green color Changing , (000—255)
Change the color by B or C button
8| B000| Blue color Changing , (000—255)
Change the color by B or C button
9| W000| White color Changing , (000—255)
Change the color by B or C button
---|---|---
10| Y000| Yellowcolor Changing , (000—255)
Change the color by B or C button
11| I000| Iellowcolor Changing , (000—255)
Change the color by B or C button

3.DMX512 Channels

Channels Function Details
CH.1 Dimmer R / G / B /W/Y/ Idimmer , linear , dark

→bright
CH.2| Strobe| R / G / B /W /Y/ Istrobe, ** slow →fast
CH.
3| Stand alone|
CH
.4| Stand alone speed| Function Speed, slow →fast
CH.5| R| R dimmer, linear, dark–bright
CH.6| G| G dimmer, linear, dark–bright
CH.7| B| B dimmer, linear, dark–bright
CH.8| W| W dimmer, linear, dark–bright
CH.9| Y| Y dimmer, linear, dark–bright
CH.10| I| I** dimmer, linear, dark–bright

Cleaning

As the smoke and dust corrosion, internal and external vision lens must be cleaned out to make the light output power optimization.

  1. Use the glass cleaner and soft cloth to clen the package.
  2. Every 20 days, use the glass cleaner and soft cloth to clean the external lens.
  3. When you insert the power is always to ensure that every part of the product dry.

When Fixtures run, require regular cleaning according to the different environments.

Instruction:

In order to make the product to run as efficiently as possible, please carefully read the operating instructions to become familiar with the basic operation of products. This Operation Guide contains information on use and maintenance of the important safety information.
Products: -LED-PAR
Voltage: 110V-240V;50/60HZ
Color: RGBWYI
Led lamp:5IN1/6IN1(RGBWYI)
Gross weight: 9kg
MEAS :310310380mm