How to Install the Device?
Installation Environment
Please refer to the following recommendations for installation.
Device Installation
With Backplate ★:
- Attach the mounting template sticker to the wall, and drill holes according to the mounting paper.
- Fix the Backplate on the wall using wall mounting screws.
- Attach the device to the Backplate.
- Fasten the device to the Backplate with a security screw.
With Back Cover:
- Attach the mounting template sticker to the wall, and drill holes according to the mounting paper.
- Fix the Back Cover on the wall using wall mounting screws.
- Attach the device to the Back Cover.
- Fasten the device to the Back Cover with a security screw.
Wiring Diagram
Power Connection
Recommended AC Adapter
- 12V ± 10%, at least 3000mA.
- To share the power with other devices, use an AC Adapter with higher current ratings.
Ethernet Connection
Connect the device and computer software over an Ethernet cable. As shown in
the example below:Click on [COMM.] > [Ethernet] > [IP Address] , input
the IP address and click on [OK].
Note: In LAN, the IP addresses of the server (PC) and the device must be
in the same network segment when connecting to the software.
Wiegand Reader and RS485 Connection Door Sensor, Exit Button, Auxiliary
Connection Lock Relay Connection
The system supports Normally Opened Lock and Normally Closed Lock.
The NO LOCK (normally unlocked when power-on) is connected with ‘NO’ and ‘COM’
terminals, and the NC LOCK (normally locked when power-on) is connected with
‘NC’ and ‘COM’ terminals. Take NC Lock as an example below:
-
Device not sharing power with the lock
-
Device sharing power with the lock
Printer Connection