PRODUCT FEATURES

  • Used to Upgrade existing 2×4 fluorescent recessed troffer, without modifying existing fixture mounting.
  • CCT Selectable (3500K, 4000K, or 5000K)
  • Wattage Selectabe (50W, 40W, or 30W)
  • Construction features precise optical lenses over each individual LED, offering optimal light diffusion and consistent surface illumination, with no risk of yellowing over product lifetim

PERFORMANCE SPECIFICATIONS

Catalog Number| Input Voltage| Wattage| Color Temperature| Lumen Output| CRI| Power Factor| Efficacy| Lifetime
---|---|---|---|---|---|---|---|---

PRK-LED-24-50PS-8CSA*

|

120-277V

|

50W

| 3500K| 5,500|

80

|

0.9

| 110 lm/W|

50,000 Hours

4000K| 5,600| 112 lm/W
5000K| 5,600| 112 lm/W

120-277V

|

40W

| 3500K| 4,400| 110 lm/W
4000K| 4,500| 113 lm/W
5000K| 4,500| 113 lm/W

120-277V

|

30W

| 3500K| 3,300| 110 lm/W
4000K| 3,400| 113 lm/W
5000K| 3,400| 113 lm/W
ONE CATALOG NUMBER WITH 9 DIFFERENT OPTIONS

  • Preset to highest lumen output (50W / 5000K)
  • Color Uniformity: CCT (Correlated Color Temperature) range as per guidelines outlined in ANSI C78.377-2017.

PHOTOMETRIC SPECIFICATIONS

PHOTOMETRIC SPECIFICATIONS

Zone Lumens % Luminaire
0-60 4,349.9 77.8%
60-90 1,240.4 22.2%
0-90 5,590.3 99.9%
90-180 2.7 0.05%
0-180 5,493.0 100%

NOTE: Charts are represeneted by 5000K

PHOTOMETRIC SPECIFICATIONS

WEIGHT INFORMATION

1 Piece
12.5 lbs

INSTALLATION INSTRUCTIONS

Always turn off the power supply from main circuit breaker first!

  1. Dismantle accessories from the original housing (ballast, fluorescent tube, sockets, bracket and other accessories that may interfere the installation). Note: The original housing must be retained in place. Reserve the L&N wire of original housing to connect retrofit kit in later step. Plug previous holes from ballast with appropriate screws and nuts
    INSTALLATION INSTRUCTIONS

  2. Insert the two brackets into the clearance between the housing and T-grid
    INSTALLATION INSTRUCTIONS

  3. Insert the two side bars into the clearance between the brackets and the T-grid.
    INSTALLATION INSTRUCTIONS

  4. Using the included self-tapping screws, use electronic screwdriver to secure brackets into place through bracket mounting holes from inside of the fixture. Caution: Luminaire wiring and electrical parts may be damaged when drilling for installation of LED retrofit kit. Ensure that enclosed wiring and components have not been damaged.
    INSTALLATION INSTRUCTIONS

  5. Embed the rotary screws on the edge of the panel into the bracket chutes. Push to the end in the direction of chutes to secure panel.
    INSTALLATION INSTRUCTIONS

  6. Connect L&N wire from original housing to the driver of the retrofit using appropriate connectors. If using 0-10V dimmer, connect DIM+,DIM- to 0-10V dimmer wires. Connect the green ground wire of the retrofit kit to the fixture with a wiring cap to ensure grounding safety
    INSTALLATION INSTRUCTIONS

  7. Attach clips from the retrofit kit to the brackets.
    INSTALLATION INSTRUCTIONS

  8. Close the retrofit kit door into the fixture and rotate the clips to secure the door closed.
    INSTALLATION INSTRUCTIONS

COMPONENT SUMMARY

CATALOG NUMBER QUANTITY

LED Module including – LED Driver/Power Supply and LED Array (Not Field Replaceable)| 1
Mounting Bars| 2
Mounting Brackets| 2
Installation Instructions| 1
Luminaire Marking Labels| 1
Miscellaneous Hardware include 4 pcs M4.6*13 screws| 1

ORDERING INFORMATION

CATALOG NUMBER CARTON QTY. EASY CODE UPC
PRK-LED-24-50PS-8CSA 1 EZC-37 843654136714