Ablerex 6000VA – 10000VA MARS III Tower Instructions

June 9, 2024
Ablerex

Ablerex 6000VA – 10000VA MARS III Tower

6000VA – 10000VA

The ability to install up to four units in parallel means that the maximum redundancy level is always guaranteed

Ablerex-6000VA-10000VA-MARS-III-Tower-FIG-1

FEATURES

  • Maximum power availability: kVA=kW.
  • Up to 4 units in parallel, 3 + 1 redundancy possible with parallel kit.
  • Low running costs: the high efficiency VFI and ECO features minimise energy consumption.
  • User-friendly monitoring software can be downloaded free and is compatible with the main operating systems, for: monitoring functions, diagnostics, controlled shutdown of loads in the event of faults.
  • Cold start.
  • Wide input voltage and frequency ranges reduce battery switching, thereby increasing battery life and efficiency.
  • Flexible battery configuration to suit your uptime requirements.
  • Accurate calculated remaining uptime is shown on the display.
  • Hot-swappable batteries: the batteries can be replaced while the UPS is running.
  • Firmware can be upgraded easily to implement new features.
  • EPO and On/Off, with remote option.
  • 6-step operation test that can be activated manually.
  • RS232 and USB ports, slots for optional communication cards.

KEY OPTIONS

  • Cards: RS485, SNMP/web and relay card with dry contacts to send the UPS status to various systems, such as BMS, PLC, SCADA and AS400
  • Parallel kit.
  • External battery cabinets.
  • External manual bypass with additional sockets.

BACK PANEL

Ablerex-6000VA-10000VA-MARS-III-Tower-FIG-2

MARS III TOWER TECHNICAL DATA SHEET

MODEL MS III 6000 MS III 10000

POWER

| VA| 6000| 10000
W| 6000| 10000



INPUT

| Rated voltage*| 110–280 Vac
Frequency| 45–70 Hz
Power factor| >0.99







OUTPUT

| Rated voltage| 200/208/220/230/240 Vac selectable
Voltage distortion| <2% with linear load, <7% with distorting load
Voltage stability| ±1%
Frequency| 50/60 Hz (selectable)
Frequency stability| £ 0.2% (free running)
Power factor| 1
Crest factor| 3:1
Waveform| Pure sine wave
Output connection| Terminal blocks


EFFICIENCY

| VFI mode| Up to 94%
ECO mode| Up to 98%







GENERAL

| Dimensions (WxDxH) mm| 240x700x513| 288x700x513
Weight (kg)| 53| 78
Alarms| Audible and visual alarm alerts for: power failure, low battery, bypass transfer, and UPS fault.
Protection| Overload, overheating, short circuit, deep discharge, battery overcharging.
Operating mode| Multi-mode: VFl, ECO, frequency converter (CVCF)
Cold start from the battery without mains power| ****

Included

Parallel connection| Up to 4 units for 3+1 redundancy




BATTERY

| Battery type| 12V VRLA, AGM (maintenance-free lead)
Uptime with internal battery (in minutes).| 50% load| 12| 11
100% load| 4| 4
Charging time (90%)| 4–6 hours
Battery expansion module dimensions (WxDxH) **| 288x663x661



ENVIRONMENTAL PARAMETERS

| Operating temperature***| 0–40°C
Relative humidity| 0%–90% (non-condensing)
Altitude (a.s.l.)| <1000 m with no power derating, >1000 m with 1% derating for every 100 m.
Audible noise at 1 m.| £60 dBA




CONNECTIVITY

| Built-in communication ports| USB, RS232, EPO On/Off contact, and additional slots for optional cards
User interface| LCD and function keys (parameters: voltage, frequency, load percentage, battery voltage, output voltage, estimated uptime, UPS temperature).
Optional accessories| Cards: SNMP, RS485 ModBus, dry relay contacts
Compatible software platforms| Microsoft Windows, Linux, Mac OS, VMware


REGULATIONS

| Standards| IEC EN 62040-1, IEC EN 62040-2, IEC EN 62040-3
Marking| CE

Data may be subject to change without notice due to our commitment to continuous innovation – rev 22_06

  • Depending on the load
  • Battery weight and configuration depends on the required uptime
  • To be verified according to the battery parameters