Ablerex 6000VA – 10000VA MARS III Tower Instructions
- June 9, 2024
- Ablerex
Table of Contents
Ablerex 6000VA – 10000VA MARS III Tower
6000VA – 10000VA
The ability to install up to four units in parallel means that the maximum redundancy level is always guaranteed
FEATURES
- Maximum power availability: kVA=kW.
- Up to 4 units in parallel, 3 + 1 redundancy possible with parallel kit.
- Low running costs: the high efficiency VFI and ECO features minimise energy consumption.
- User-friendly monitoring software can be downloaded free and is compatible with the main operating systems, for: monitoring functions, diagnostics, controlled shutdown of loads in the event of faults.
- Cold start.
- Wide input voltage and frequency ranges reduce battery switching, thereby increasing battery life and efficiency.
- Flexible battery configuration to suit your uptime requirements.
- Accurate calculated remaining uptime is shown on the display.
- Hot-swappable batteries: the batteries can be replaced while the UPS is running.
- Firmware can be upgraded easily to implement new features.
- EPO and On/Off, with remote option.
- 6-step operation test that can be activated manually.
- RS232 and USB ports, slots for optional communication cards.
KEY OPTIONS
- Cards: RS485, SNMP/web and relay card with dry contacts to send the UPS status to various systems, such as BMS, PLC, SCADA and AS400
- Parallel kit.
- External battery cabinets.
- External manual bypass with additional sockets.
BACK PANEL
MARS III TOWER TECHNICAL DATA SHEET
MODEL | MS III 6000 | MS III 10000 |
---|
POWER
| VA| 6000| 10000
W| 6000| 10000
INPUT
| Rated voltage*| 110–280 Vac
Frequency| 45–70 Hz
Power factor| >0.99
OUTPUT
| Rated voltage| 200/208/220/230/240 Vac selectable
Voltage distortion| <2% with linear load, <7% with distorting load
Voltage stability| ±1%
Frequency| 50/60 Hz (selectable)
Frequency stability| £ 0.2% (free running)
Power factor| 1
Crest factor| 3:1
Waveform| Pure sine wave
Output connection| Terminal blocks
EFFICIENCY
| VFI mode| Up to 94%
ECO mode| Up to 98%
GENERAL
| Dimensions (WxDxH) mm| 240x700x513| 288x700x513
Weight (kg)| 53| 78
Alarms| Audible and visual alarm alerts for: power failure, low battery,
bypass transfer, and UPS fault.
Protection| Overload, overheating, short circuit, deep discharge, battery
overcharging.
Operating mode| Multi-mode: VFl, ECO, frequency converter (CVCF)
Cold start from the battery without mains power| ****
Included
Parallel connection| Up to 4 units for 3+1 redundancy
BATTERY
| Battery type| 12V VRLA, AGM (maintenance-free lead)
Uptime with internal battery (in minutes).| 50% load| 12| 11
100% load| 4| 4
Charging time (90%)| 4–6 hours
Battery expansion module dimensions (WxDxH) **| 288x663x661
ENVIRONMENTAL PARAMETERS
| Operating temperature***| 0–40°C
Relative humidity| 0%–90% (non-condensing)
Altitude (a.s.l.)| <1000 m with no power derating, >1000 m with 1% derating
for every 100 m.
Audible noise at 1 m.| £60 dBA
CONNECTIVITY
| Built-in communication ports| USB, RS232, EPO On/Off contact, and
additional slots for optional cards
User interface| LCD and function keys (parameters: voltage, frequency, load
percentage, battery voltage, output voltage, estimated uptime, UPS
temperature).
Optional accessories| Cards: SNMP, RS485 ModBus, dry relay contacts
Compatible software platforms| Microsoft Windows, Linux, Mac OS, VMware
REGULATIONS
| Standards| IEC EN 62040-1, IEC EN 62040-2, IEC EN 62040-3
Marking| CE
Data may be subject to change without notice due to our commitment to continuous innovation – rev 22_06
- Depending on the load
- Battery weight and configuration depends on the required uptime
- To be verified according to the battery parameters