Ablerex CPSS ZEN Single Phase 4000-10000 VA Instructions
- September 21, 2024
- Ablerex
Table of Contents
CPSS ZEN Single Phase 4000-10000 VA
“`html
Specifications
- Model: CPSS ZEN
- Compliance: EN 50171
- Single-phase Capacity: 4000-10000 VA
- Three-phase Capacity: 10-40 kVA
Product Usage Instructions
Operating Modes
Online Mode (VFI): The load is always powered
by the inverter.
ECO Mode: The load is powered by the bypass
during normal operation and by the inverter when there is no mains
or it is out of tolerance.
Emergency Mode (SE): The load is only powered
by the inverter when there is no mains or it is out of
tolerance.
Mixed Mode: One load is always powered by the
inverter, while the other load is only powered by the inverter when
there is no mains or it is out of tolerance. The three-phase
version requires the optional Mixed Mode Kit.
Components
The CPSS ZEN system consists of:
- Static switch
- Rectifier
- Inverter
- Battery
- Emergency Load
- Continuous Load
Accessories
The CPSS ZEN system offers various accessories including:
-
External Bypass Panels (MTBS-60, MTBS-120, MTBS-200,
Rack-BP_PDU-50) -
Isolation Transformers (TRAFO06, TRAFO10, TRAFO20, TRAFO30,
TRAFO40) -
Parallel Kit (PARRIT KR, PARCAB30, PARCAB80)
-
Mixed Mode Kit (OP4ZEN)
FAQ
Q: What are the different operating modes of the CPSS ZEN
system?
A: The CPSS ZEN system operates in Online Mode
(VFI), ECO Mode, Emergency Mode (SE), and Mixed Mode.
Q: What accessories are available for the CPSS ZEN system?
A: Accessories include External Bypass Panels,
Isolation Transformers, Parallel Kits, and Mixed Mode Kits.
Q: What certifications does the CPSS ZEN system have?
A: The CPSS ZEN system is fully EN 50171
compliant and certified by a third party.
“`
SINGLE AND THREE-PHASE CPSS
CPSS ZEN
EN 50171 compliant CPSS designed to ensure the highest degree of protection in
the critical environments of all emergency system installations.
For everyone’s peace of mind: designers, retailers, installers and end users.
CPSS ZEN single-phase 4000-10000 VA
CPSS ZEN three-phase 10-40 kVA
Applications
· Emergency lighting · Fire alarm systems · Smoke extraction systems · Gas and
smoke detection systems
· Security alarm systems · PAV Voice Systems · Lone Worker Systems
Three-phase CPSS ZEN 1020 kVA
Three-phase CPSS ZEN 3040 kVA
Single-phase CPSS ZEN 46 VA CPSS ZEN 810 VA
SINGLE AND THREE-PHASE CPSS
CPSS ZEN
· Fully EN 50171 compliant with third party test certificate, the ZEN CPSS is
a real Central Power Supply System that meets all legal requirements for the
protection of emergency and safety systems.
· Easy to install: smallest footprint among EN 50171 compliant products.
· Wide variety of audible and visual alarms including: battery polarity
reversal, CPSS and battery charger short circuit, power failure, low battery,
bypass transfer, CPSS fault.
· Cold start from the battery without mains power.
· Maximum efficiency (up to 98%) and flexibility thanks to the 4 operating
modes.
· The single-phase version includes mixed, online and SE modes with separate
outputs, while the three-phase version requires optional accessories.
· Dual input and internal manual bypass for simple, completely safe
maintenance.
· High overload capacity: delivers up to 120% of the rated power indefinitely.
· Easy and fast connection guaranteed by the terminals, which have been
enlarged in the single-phase version.
· Option of internal battery with housing for 40 9Ah batteries for three-phase
10 and 20 kVA models (with optional tray kit only), giving a compact solution
for small-load applications.
· Protection against load-side short circuits and battery polarity reversal,
without the risk blowing fuses during commissioning, even in the event of
reversal.
· Shorter charging time and longer battery life thanks to high charge current
with temperature compensation.
· Accurate calculated remaining uptime is shown on the display.
· Hot-swappable batteries: the batteries can be replaced while the CPSS is
running.
· Greater flexibility offered by the internal charger that is easy to set from
the display.
· Battery life of 10 years.
· Heat and fire resistant IP20 casing that is EN 60598-1 compliant.
· Easily upgradeable firmware.
· RS232, USB and EPO ports built-in, and slots for optional communication
cards. Remote on/off available in the single-phase version.
Fully EN 50171 compliant with third party test certificate
Key options
· Cards: SNMP, RS485 ModBus and relay card with dry contacts · EN 50272-2
compliant battery cabinet
CPSS ZEN single-phase
· Additional battery charger for long runtimes
CPSS ZEN three-phase
· Parallel kit · Mixed mode kit
SINGLE AND THREE-PHASE CPSS
CPSS ZEN
Accessories
CPSS ZEN single-phase
COMMUNICATION CARDS for sending the CPSS status to a control computer DCE-C:
Programmable card with dry contacts with dry contacts with client software
included. SNMP ABL: Network card CY504B for sending data, controlling CPSS and
receiving alarms via email with SNMP protocol. Client software is included.
SNMP GEN P: 3-port Generex card (CS141SC) for controlling CPSS, and receiving
alarms via SMS or/and email. Includes network interface for sending data with
SNMP protocol, port for environmental monitoring sensor connection or RS232
adapter (ModBus or GPRS/GSM modem),and port connecting alarm contacts. One
RCCMD client software is included. SNMP GEN: Network card (CS141BSC) for CPSS
control, sending data, and reception of alarms via email, via SNMP protocol.
One RCCMD client software license is included. RS485 CARD: Internal for data
exchange via the R485 protocol.
EXTERNAL BYPASS to ensure power continuity to the load during maintenance
MTBS-60: 60A bypass panel. MTBS-120: 120A bypass panel. MTBS-200: 200A bypass
panel. Rack-BP_PDU-50: External manual bypass with additional 50A sockets (4 x
16A IEC and 8 x 10A IEC) or powered by CPSS.
ISOLATION TRANSFORMERS for protection against electric shocks and ensure power
availability to sensitive equipment TRAFO06: Transformer for 6 kVA. TRAFO10:
Transformer for 10 kVA.
CPSS ZEN three-phase
COMMUNICATION CARDS for sending the CPSS status to a control computer SNMP
GEN: Generex network card (CS141BSC) for sending data with SNMP protocol for
UPS control and reception of alarms via email. One RCCMD client software
license included. TS-KR-SNMP-1: Network card for sending data with SMNP
protocol for controlling the UPS and reception of alarms via sms or/and email
and, with port to measure temperature and humidity. Client software included.
TS-KR-EMD: Environmental monitoring sensor for SNMP card with temperature and
humidity monitoring. TS-KR-485: Card for data exchange via the RS-485
protocol. TS-KR-DEC: 6 in 6 out programmable relay card with dry contacts for
sending data to PLC, SCADA or AS400.
ISOLATION TRANSFORMERS for protection against electric shocks and ensure power
availability to sensitive equipment TRAFO10: Transformer for 10 kVA. TRAFO20:
Transformer for 20 kVA. TRAFO30: Transformer for 30 kVA. TRAFO40: Transformer
for 40 kVA.
PARALLEL KIT to share the load among more than one CPSS to increase capacity
and redundancy PARRIT KR: Parallel kit composed of card and 1.5 m cable.
PARCAB30: 3 m parallel connection cable. PARCAB80: 8 m parallel connection
cable.
MIXED MODE KIT: to have SA and SE with separate outputs MIXED. OP4ZEN: wall-
mounted kit with contactor for mixed mode 40 kW (150A).
SINGLE AND THREE-PHASE CPSS
CPSS ZEN
Operating mode
Online mode (VFI) The load is always powered (SA) by the inverter.
AC Source
ECO mode The load is powered by the bypass during normal operation and by the inverter when there is no mains or it is out of tolerance.
AC Source
Emergency mode (SE)
The load is only powered by the inverter when there is no mains or it is out
of tolerance.
AC Source
Mixed mode One load is always powered by the inverter, while the other load is only powered by the inverter when there is no mains or it is out of tolerance (SA and SE with separate outputs). The three-phase version required the optional Mixed mode kit.
AC Source
Static switch
Rectifier
Inverter
Battery
Static switch
Rectifier
Inverter
Battery
Static switch
Rectifier
Inverter
Battery
Static switch
Rectifier
Inverter
Battery
Emergency load
Emergency load
Emergency load
Continuous load
Emergency load
SINGLE AND THREE-PHASE CPSS
Central Power Supply System, fully EN 50171 compliant certified by third party
CPSS Zen 1/1 4000-10000 VA
SINGLE AND THREE-PHASE CPSS CPSS Zen 3/3
10-40 kVA
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>