OLEI LR-16F 3D LiDAR Sensor Communication Data Protocol User Manual

June 9, 2024
OLEI

OLEI LR-16F 3D LiDAR Sensor Communication Data Protocol

Please read this manual before using the product for the best product performance.
Be sure to keep this manual for future reference.

Type of Connector

  1. Connector: RJ-45 standard internet connector
  2. Basic protocol: UDP/IP standard internet protocol, Data are in little-endian format, lower byte first

Data Packet Format

Overview

OLEI-LR-16F-3D-LiDAR-Sensor-Communication-Data-Protocol-
fig-2

The total length of a data frame is 1248 bytes, including:

  • Frame header: 42 bytes
  • Data block: 12X(2+2+96) = 1,200 bytes
  • Time stamp : 4 Bytes
  • Factory mark: 2 Bytes

Header

Offset Length Description


0

| ****


14

| Ethernet II include: Destination MAC:(6 Byte) Sourse MAC:(6 Byte)

Type: (2 Byte)







14

| ****






20

| Internet Protocol include:

Version & Header Length :(1 Byte) Differentiated Services Field: (1 Byte) Total Length:(2 Byte)

Identification: (2 Byte)

Flags: (1 Byte)

Fragment Offse: (1 Byte) Time to Live: (1 Byte) Protocol: (1 Byte)

Header Checksum: (2 Byte)

| | Destination IP: (4 Byte)

Sourse IP: (4 Byte)

---|---|---



34

| ****


8

| User Datagram Protocol include: Sourse Port:(2 Byte) Destination Port: (2 Byte)

Data Length:(2 Byte)

Checksum: (2 Byte)

Data block definition
The laser returned data consists of 12 data blocks. Each data block starts with a 2-byte identifier 0xFFEE, followed by a 2-byte azimuth angle and a total of 32 data points. The lase returned value of each channel contains a 2-byte distance value and a 1-byte calibration reflectivity value.

Offset Length Description
0 2 Flag, it is always 0xFFEE
2 2 Angle Data
4 2 Ch0 Ranging Data
6 1 Ch0 Reflectivity Data
7 2 Ch1 Ranging Data
9 1 Ch1 Reflectivity Data
10 2 Ch2 Ranging Data
12 1 Ch2 Reflectivity Data
49 2 Ch0 Ranging Data
51 1 Ch15 Reflectivity Data
52 2 Ch0 Ranging Data
54 1 Ch0 Reflectivity Data
55 2 Ch1 Ranging Data
57 1 Ch1 Reflectivity Data
58 2 Ch2 Ranging Data
60 1 Ch2 Reflectivity Data
97 2 Ch15 Ranging Data
99 1 Ch15 Reflectivity Data

The vertical angle is defined as following:

Laser ID Vertical Angle
0 -15°
1
2 -13°
3
4 -11°
5
6 -9°
7
8 -7°
9
10 -5°
11 11°
12 -3°
13 13°
14 -1°
15 15°

OLEI-LR-16F-3D-LiDAR-Sensor-Communication-Data-Protocol-
fig-3

Time stamp

Offset Length Description

0

| ****

4

| Timestamp [31:0]: [31:20] count of Seconds [19:0] count of Microsecond

Factory mark

Offset Length Description
0 2 Factory:(2 Byte)0x00,0x10

Example

OLEI-LR-16F-3D-LiDAR-Sensor-Communication-Data-Protocol-
fig-4
OLEI-LR-16F-3D-LiDAR-Sensor-Communication-Data-Protocol-
fig-5

Communication protocol-information package

Overview

Header Lidar Info GPS Info
42 Bytes 768Bytes 74 Bytes

Length of data package: 884 Bytes
Note: The port number of the information package cannot be changed, the local and target ports are both 9866

Definition of header

Offset Length Description


0

| ****


14

| Ethernet II Include: Destination MAC:(6 Byte) Sourse MAC:(6 Byte)

Type: (2 Byte)



14

| ****


20

| Internet Protocol Include:

Version & Header Length :(1 Byte) Differentiated Services Field: (1 Byte) Total Length:(2 Byte)

Identification: (2 Byte)

| | Flags: (1 Byte)

Fragment Offse: (1 Byte) Time to Live: (1 Byte) Protocol: (1 Byte)

Header Checksum: (2 Byte) Destination IP: (4 Byte)

Sourse IP: (4 Byte)

---|---|---



34

| ****


8

| User Datagram Protocol Include: Sourse Port:(2 Byte) Destination Port: (2 Byte)

Data Length:(2 Byte)

Checksum: (2 Byte)

Definition of Lidar Info

Offset Length Description
0 6 Factory Code
6 12 Model Number
18 12 Series Number
30 4 Sourse IP
34 2 Sourse data Port
36 4 Destination IP
40 2 Destination data Port
42 6 Source MAC
48 2 Motor Speed

50

| ****

1

| [7] GPS Connection, 0: Connected, 1: No connection [6] Top circuit error flag 0: Normal, 1: Error [5:0] Reserve



51

| ****


1

| GPS Enable & Baud rate 0x00:GPS GPS Power Off

0x01:GPS Power On, Baud rate 4800 0x02:GPS Power On, Baud rate 9600

0x03:GPS Power On, Baud rate 115200

52| 1| Reserve
53| 1| Reserve
54| 2| Top circuit Temperature, DataX0.0625℃
56| 2| Bottom circuit Temperature, DataX0.0625℃
58| 2| Reserve
60| 32| CH0-CH15 Channel static offset
92| 4| Reserve
96| 672| Reserve
768| 74| GPS Information

Example

OLEI-LR-16F-3D-LiDAR-Sensor-Communication-Data-Protocol-
fig-6

Setup the protocol

Follow the UDP protocol, user setup protocol, upper computer sends 8 bytes

Name Address Data
Number of bytes 2 Bytes 6 Bytes
Address Name Byte Definition [31:0]
--- --- ---
F000 Local IP [47:16]=local_ip,[15:0] =local_port
F001 Remote IP [31:0]=remote_ip,[15:0]= remote_port

F002

|

Speed, GPS enable, baud rate

| [47:32] =rom_speed_ctrl [31:24]=GPS_en 0x00 = off

0x01 = enabled and the baud rate is 4800 0x02= enabled and the baud rate is 9600 0x03 = enabled and 115200 baud rate

[23:0]Reserved
Example:| |
Local ip and port| F0 00 C0 A8 01 64 09 40| 192.168.1.100 2368
Target ip and port| F0 01 C0 A8 01 0A 09 40| 192.168.1.10 2368
Rotating speed| F0 02 02 58 00 00 00 00| speed 600

Example:

  • Local ip and port F0 00 C0 A8 01 64 09 40 192.168.1.100 2368
  • Target ip and port F0 01 C0 A8 01 0A 09 40 192.168.1.10 2368
  • Rotating speed F0 02 02 58 00 00 00 00 speed 600
  • Restart the 3D LiDAR each time the modification is completed.
  • Optional rotating speed: 300 or 600. optional baud rate:4800/9600/115200 .

Coordinate conversion

The information in the LR-16F data package is the azimuth value and distance value established in the polar coordinate system. It’s more convenient to construct three-dimensional scene through the point cloud data by converting polar coordinate value to Cartesian coordinate system.
The above values corresponding to each channel is shown in the following table:

Channel#

| Vertical angle

(ω)

| Horizontal angle

(α)

| Horizontal offset

(A)

| Vertical offset

(B)

---|---|---|---|---
CH0| -15°| α| 21mm| 5.06mm
CH1| 1°| α+10.00108H| 21mm| -9.15mm
CH2| -13| α+20.00108H| 21mm| 5.06mm
CH3| 3°| α+30.00108H| 21mm| -9.15mm
CH4| -11| α+40.00108H| 21mm| 5.06mm
CH5| 5°| α+50.00108H| 21mm| -9.15mm
CH6| -9| α+60.00108H| 21mm| 5.06mm
CH7| 7°| α+70.00108H| 21mm| -9.15mm
CH8| -7| α+80.00108H| -21mm| 9.15mm
CH9| 9°| α+90.00108H| -21mm| -5.06mm
CH10| -5| α+100.00108H| -21mm| 9.15mm
---|---|---|---|---
CH11| 11°| α+110.00108H| -21mm| -5.06mm
CH12| -3| α+120.00108H| -21mm| 9.15mm
CH13| 13°| α+130.00108H| -21mm| -5.06mm
CH14| -1| α+140.00108H| -21mm| 9.15mm
CH15| 15°| α+150.00108H| -21mm| -5.06mm

Note: Under normal accuracy, the horizontal angle α only needs to increase the parameters in the table above.

The calculation formula for space coordinates is

OLEI-LR-16F-3D-LiDAR-Sensor-Communication-Data-Protocol-
fig-9

Definitions:

  • The measured distance output by each channel of the LiDAR is set as R. Note that the unit of the LiDAR input is 2mm, please convert to 1mm first
  • Rotating speed of LiDAR is set as H (usually 10Hz)
  • The vertical angle of each channel of the LiDAR is set as ω
  • The horizontal angle output by the LiDAR is set as α
  • The horizontal offset of each channel of the LiDAR is set as A
  • The vertical offset of each channel of the LiDAR is set as B
  • The spatial coordinate system of each channel of the LiDAR is set to X, Y, Z

OLEI-LR-16F-3D-LiDAR-Sensor-Communication-Data-Protocol-
fig-8

ABOUT COMPANY

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>