OLEI A090 Laser Distance Sensor User Manual

June 4, 2024
OLEI

Quick Start Use ManualOLEI A090 Laser Distance
Sensor

A090
Laser Distance Sensor
Sensing Reality

Electrical parameters and specifications

Table 1 Electrical characteristics

Parameter Name Parameter values
Input voltage 7-26V
Average current 100mA(Vin= 10V)
Peak current <150mA(Vin= 10V)
Type of communication interface RS485, CAN, 1 analog output,2 switching

output, 1 switching input
Power consumption| <1.5W

Table 2 Basic parameters

Measuring principle Phalle
Measuring range 0.05-90m(90%,300Iux,single) 0.2-45m(90%,300Iux,30Hz) –I
Resolution 0.1mm
Measurement reference Front-end distance measuring sensor
Accuracy ±1.5mm (90% diffuse reflection <20m)

±3.0mm (full range)
Measuring frequency| Support single measurement and continuous measurement: frequency of continuous measurement:
5Hz,10Hz,20Hz, and 30Hz are available.
Light source| 650-660nm
Laser class| Class II (laser power is between 0.75-0.95mW)
Typical spot size (distance)| 7mm©10m
Initialization lime| <1000ms
Holder material| Metal (aluminum)
Type of connection| M12,12P,Male
Weight(excluding accessories and packaging materials)| 350g
Dimensions(width x length x height)| 79•127•31mm

Notice: *1 The specific measurement range will change due to the measuring frequency, light intensity, and target reflectivity.

Appearance and dimension

2.1 Appearance

OLEI A090 Laser Distance Sensor - fig

2.2 Installation dimension

OLEI A090 Laser Distance Sensor - fig1

Instruction of wiring

3.1 Description of interface terminal
The external interface adopts 12P, M12 male aviation plug, and the pin sequence is as shown in the figure below:

A 2m-long 12-core molding cable is included, with one end of an M 12 female aviation plug, and the other end of colored wire.

PIN Definition Description
2 V+ 7 … 26V
3 GND av
4 1 Switching output channel 1, push-pull output, maximum drive current

200mA
5| 2| Switching output channel 2, push-pull output, maximum drive current 200mA
6| VCC| 10 voltage, 12V-24V
8| 485A| 485 output A
7| 485B| 485 output B
8| Multi1| CANH, IIC_SDA,5VIO(toggle switch to shift; program functions also need to be  set to corresponding functions through parameters), default to CANH
9| Multi2| CANL, IIC_SCL,5VIO(toggle switch to shift; program functions also need to be  set to corresponding functions through parameters), default to CANL
10| INDIO| 10 ground
11| 11| INPUT1, switching input channel 1, when not connected, it is high- level, Active low
12| analogous| Analog signal output, support -5V,0-10V,4-20mA, 0-20mA,0-24mA,parameter  selection is required, default to 4-20mA out ut

Notice:

  1. The 485 interfaces, CAN interface, analog output, 10 output, and input all adopt a fully isolated design. Thus do not connect VCCIO and GNDIO with V+ and GND  together, otherwise, the effect of power isolation will not be achieved.
  2. If only 485 and CAN are used, VCCIO and GNDIO may not be connected. If the switching output and input functions are used, VCCIO and GNDIO must be connected.
  3. If the analog output is used, GNDIO should be taken as the reference ground.
  4. Communication interface description

4.1 RS485 Modbus RTU communication protocol
Please refer to “Industrial Ranging Sensor Modbus RTU Communication Protocol” for detailed information.
4.2 CAN communication protocol
The CAN communication protocol supports standard frames and extended frames; the communication parameters could be set via the RS485 bus. Please refer to “Industrial  Ranging Sensor Modbus RTU Communication Protocol” for a detailed CAN communication setting method. For CAN communication protocol, please refer to “Industrial  Ranging Sensor
CAN Communication Protocol”.
4.3 Analog output
There are 6 options for analog output function, namely:
=0 off
=1 0-5V
=2 0-10V
=3 4-20mA
=4 0-20mA
=5 0-24mA
The configuration parameters should be set via the RS485 bus. Please refer to “Industrial Ranging Sensor Modbus RTU Communication Protocol” for details.

4.4 Switching outputs
The switching output is in push-pull mode and supports two modes of output setting, namely (1: ON> OFF, 2: ON <OFF). The device automatically judges the mode according to the set hysteresis parameters.

  1. Hysteresis parameter: ON level>OFF level
    OLEI A090 Laser Distance Sensor - fig2The 10 output configuration parameters should be set via the RS485 bus.
    Please refer to “Industrial Ranging Sensor Modbus RTU Communication Protocol” for details.

4.5 Switching input
The functional parameters of the switching input have three modes, as shown below:
=0 off
=1 not connected or high level to start the measurement, low level to stop measurement
=2 not connected or high level to stop measurement, low level to start measurement
10 input configuration parameters should be set via the RS485 bus.
Please refer to “Industrial Ranging Sensor Modbus RTU Communication Protocol” for details.
5. Service and maintenance
Please visit the OLEI official website for inquiry of service and maintenance information;
Website: www.ole-systems.com
Path: Service and Support>>Service and maintenance