PSU-10 EVO Power Supply
User Manual
IMPORTANT SAFETY INFORMATIONS
PLEASE NOTE
- Do not disassemble any part of the product.
- Do not use any part of the product for other purposes.
- For service and problems of any kind, contact qualified Gold Note personnel.
- Protect the product from rain, humidity and keep away from heat sources, electric and electronic motors etc. The power cord supplied must be used only on this unit.
- Gold Note does not have responsibility for any improper use of this unit.
GENERIC INFORMATION
Read these instructions and store them.
Heed all warnings.
Follow the instructions.
Do not use this apparatus near water.
Clean only with a dry cloth.
Do not block the ventilation openings and install in accordance with the
manufacturer’s instructions.
Do not install near heat sources such as radiators, heat registers, stoves or
other apparatus (including amplifiers) that produce heat.
Do not defeat the safety purpose of the polarised or grounding-type plug: a
polarised plug hastwo blades with one wider than the other.
A grounding type plug has two blades and a third grounding prong. The wide
blade or the third prong are provided for your safety.
If the provided plug does not fit into your outlet, consult an electrician for
replacement of the obsolete outlet. or pinched particularly at plugs,
convenience receptacles, and the point where they exit from the apparatus.
Only use attachments/accessories specified by the manufacturer.
Use only with the cart, stand, tripod, bracket, or table specified by the
manufacturer, or sold with the apparatus.
When a cart is used, use caution when moving the cart/apparatus combination to
avoid injury from tip-over.
Unplug this apparatus during lightning storms or when unused for long periods
of time. Refer all servicing to qualified service personnel only. Servicing is
required when the apparatus has been damaged in any way (such as when the
power cord or plug is damaged, liquid has been spilled or objects have fallen
into the apparatus, the apparatus has been exposed to rain or moisture) and in
any case when the apparatus does not operate normally or has been dropped.
This appliance has a serial number located on the rear panel.
Please record the model and serial number and retain them for your records.
MODEL
SERIAL NUMBER
CAUTION!
To reduce the risk of electric shock, do not remove cover (or back). No user-
serviceable parts inside. Refer only to qualified Gold Note service personnel
for service.
WARNING!
To prevent fire or shock hazard, do not expose this appliance to rain or
moisture.
GOLD NOTE – Information on the correct management of waste from household
Equipment pursuant to the European Directive 2012/19/EU
The crossed-out wheelie bin symbol shown on the equipment or its packaging
indicates that the product, at the end of its useful life, must be collected
separately from other waste to allow its proper treatment and recycling. The
user must therefore deliver, free of charge, the end-of-life equipment to the
centres for the separate collection of waste electrical and electronic
equipment, or return it to the dealer in accordance with the procedures
established by the legislation.
The appropriate separate collection of discarded equipment allows for proper
recycling, treatment and environmentally compatible disposal, helping to avoid
the possible dispersion of hazardous substances and negative effects on the
environment and health, favouring the reuse and/or recycling of the materials
of which the equipment is composed of. Illegal dumping of the product by the
user involves the application of administrative sanction provided for by the
legislation in force. We invite you consult the current legislation and the
measures adopted by the public service operating in your country or territory.
PACKAGE CONTENT
1x | PSU-10/EVO |
---|---|
1x | POWER CABLE |
1x | PSU CABLE |
1x | USER MANUAL |
INTRODUCTION AND FEATURES
PSU-10 (FOR THE PH-10)
The PSU-10 is a super inductive power supply designed exclusively for the
PH-10 phono stage.
The PSU-10 has been engineered with the best quality audio-grade components to
enhance the performance of the PH-10 and improve even further your system:
with the
dedicated external power supply you will get the very best music experience
out of your LPs.
For the PSU-10 we have chosen a dual choke design powered by a double inductor
driving the negative and positive high-current stages and featuring an
inductive filter on the analogue stage.
The PSU-10 delivers pure high-quality power using 4 transformers 3 of which
are dedicated exclusively to the power supply while a separated transformer
feeds the inductive filter and the two chokes.
The Gold Note proprietary Dual Choke Design perfectly filters the signal
voltages to eliminate all electrical pollution.
The PSU-10 uses its massive power supply to shield the PH-10 phono stage from
electromagnetic interference (EMI) thus insulating it effectively from the
power system.
The ultra-clean power improves the soundstage achieving better dynamics and
finer resolution of details for unmatched audio performance and listening
pleasure.
PSU-10 EVO (FOR THE DS-10)
The PSU-10 EVO is an inductive power supply designed and developed with
highquality audio components to enhance the performance of e of the DS-10
(DS-10/PLUS, DS-10 EVO/LINE).
The PSU-10 EVO comes in compact dimensions but delivers a great amount of
power to bring you to a new level of musical pleasure and leverages unique
features, including:
The Dual Choke Hybrid technology inductive filter
A 4-transformer design with three transformers dedicated to the power supply
The ultra-low-noise linear voltage regulators
PSU-10 EVO guarantees clean energy to optimally power your DS-10, creating the
ideal environment for the DS-10 to perform to the best.
Adding the PSU-10 EVO to your system will increase the level of detail and
realism of your music, achieving better dynamics, finer resolution of details
and more controlled power.
PLEASE NOTE
The PSU-10 EVO is not compatible with the PH-10 Phono Stage.
TECHNICAL SPECIFICATIONS
PSU-10
4 rail audio grade power supply
4 ultra low noise voltage regulator
Maximum variation of output voltage: 0,05%
Line noise rejection: >80dB
Common mode noise rejection: >80dB
Full power response: <2,5µs| PSU-10 EVO
4 rail audio grade power supply
2 ultra low noise voltage regulator
Maximum variation of output voltage: 0,05%
Line noise rejection: >80dB
Common mode noise rejection: >80dB
Full power response: <2,5µs
---|---
POWER
Power supply: 100-120V/220-240V with auto sense, 50/60Hz
Power consumption: 25W
Dynamic power: >50W
Standby power: <1W
Fuse 0,5A T| POWER
Power supply: 100-120V/220-240V with auto sense, 50/60Hz
Power consumption: 70W
Dynamic power: >100W
Standby power: <1W
Fuse 2A F
DIMENSIONS AND WEIGHT
Dimensions:
200W | 80H | 260D mm
290W | 180H | 390D mm – boxed
Weight: Kg. 3
Kg. 4 – boxed| DIMENSIONS AND WEIGHT
Dimensions:
200W | 80H | 260D mm
290W | 180H | 390D mm – boxed
Weight: Kg. 4
Kg. 5 – boxed
FRONT PANEL
FRONT PANEL OVERVIEW
The status LED is ON when the PSU-10/PSU10 EVO is connected to AC power and
the MASTER SWITCH is ON.
- LED status light
• Blue = ON/standby
REAR PANEL
REAR PANEL OVERVIEW
PSU-10
PSU-10 EVO
- PSU Out
- GND post
- IEC socket
- Master switch ON/OFF
QUICK START
Installing the PSU-10/PSU-10 EVO is simple and takes only a few quick steps:
- Turn OFF the unit and remove the power cord.
- Connect the external PSU to the power outlet using the supplied power cord.
- Connect the external PSU to the unit using the supplied cable (from PSU OUT to the PSU connector of the unit).
- Turn on the MASTER SWITCH on the rear panel of the external PSU.
INSTALLING THE PSU-10 AND PSU-10 EVO
For the best performance, we suggest to place the PSU on the lefthand side
with around 10/20cm of space between the units. Please avoid stacking the
units on top of each other if possible. GND SIGNAL GROUND
Every system operates in unique conditions due to the electrical interaction
between different products and the electrical wiring and the GND connector on
the PSU-10/ PSU-10 EVO allows you to try different configurations.
If the are signs of EMI (Electro Magnetic Interference) or RFI (Radio-
Frequency Interference), please try to connect the GND posts of the
PH-10/DS-10 and the PSU.
MASTER-SLAVE MODE
All our PSUs are designed to work in “Master-Slave Mode” with other Gold Note
units.
When you turn ON or put in standby the master unit (such as DS-10 or PH-10)
the PSU-10 or PSU-10 EVO will do the same so that you don’t have to control
every unit manually.
To turn completely OFF the PSU-10 or PSU10 EVO, follow these steps:
- Turn OFF the MASTER SWITCH of the master unit (such as DS-10 or PH-10).
- Turn OFF the MASTER SWITCH of PSU10 or PSU-10 EVO.
ATTENTION
When the master switch of PSU-10 and PSU- 10 EVO is ON/Standby, the status LED
is Blue.
PRODUCT REGISTRATION
PRODUCT REGISTRATION
We recommend to register the unit on our internet website within 15 days from
the purchase at
www.goldnote.it/product-registration If the unit is not registered correctly or has been purchased
from a different country of the purchaser home address the unit will not be
covered by any warranty and the registration will be refused.
Please note that the warranty does not cover in any case: Tubes, Phono
Cartridge Stylus and Batteries.
WARRANTY
All Gold Note products come with a warranty against defective materials and
workmanship.
Any service and inspection must be carried out by a Gold Note dealer or
distributor so in case you need any assistance with this product, please
contact the seller.
PLEASE NOTE
Descriptions and technical characteristics may vary at any time and without
notice.
www.goldnote.it/productregistration
WARNING
Gold Note products should only be opened, serviced and inspected by certified
Gold Note technicians and dealers. Work performed by unqualified personnel may
cause serious damage or personal injury. Opening of the product by non-
authorised personnel will void the guarantee.
In this case, contact your dealer to be advised on how the fault can be
solved.
Do not return any object directly to the factory or to the distributor without
being authorised to do so.
Discover more on our website
www.goldnote.it
TROUBLESHOOTING
PROBLEM | CAUSE | SOLUTION |
---|---|---|
The LED on the front panel is OFF. | The POWER CORD is damaged or not plugged | |
in. | Ensure that the POWER CORD is not damaged and connect it properly to the |
power outlet and the AC plug on PSU-10/PSU10 EVO.
The MASTER SWITCH is OFF.| Turn ON the MASTER SWITCH on the rear panel of
PSU-10/PSU-10 EVO.
The PH-10 is not showing the icon that indicates the PSU-10 is connected. The
DS-10 LED does not light up when powered by the PSU-10 EVO.| The PSU
CONNECTION CABLE is not connected
properly.| Ensure that the PSU CONNECTION CABLE is not damaged and connect it
properly to the PSU OUT port on the PSU-10/PSU-10 EVO and to the PSU port on
the
master unit.
The system is noisy.| The PSU-10/PSU-10 EVO is not correctly placed.| Ensure
that the PSU-10/ PSU-10 EVO is placed to the LEFT HAND SIDE of the master unit
and possibly at some distance.
CLEANING THE UNIT
With EXTREME care use ONLY water or detergents for delicate surfaces with a
very soft cloth to sweep dust and remove stains.
Any acid or not extremely soft cloth will irreversibly damage the unit fine
aesthetic. Do not use alcohol.
Thank you for purchasing one of our units and welcome into the Gold Note
world, where we turn High-End audio and music into a new experience.
Maurizio Aterini,
founder of Gold Note
FRENCH USER MANUAL Scan the QR-Code or go to
https://www.goldnote.it/download/manual/FR_PSU-10EVO.pdf
Designed and handmade in Firenze, Italy
www.goldnote.it
copyright ©2023 Akamai S.r.l. All rights reserved
References
- Home | Gold Note
- Home | Gold Note
- Product registration | Gold Note
- Produktregistrierung | goldnote
- Registrazione prodotto | goldnote
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>