ALDERON Industries VLIO-0002 VersAlarm I/O Indoor/Outdoor Alarm Panel User Guide
- June 9, 2024
- ALDERON Industries
Table of Contents
- VersAlarm™ I/O
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
VersAlarm™ I/O
Indoor/Outdoor Alarm Panel | Model: VLIO-0002
QUICK START GUIDE
QSG00002_Rev05_VLIO-0002_VersAlarm IO | September 19, 2022 10:47 AM
Safety Guidelines
WARNING
Before proceeding with the installation or operation of this product, read all instructions thoroughly, as well as complying with all federal, state and local codes, regulations, and practices. This product must be installed by qualified personnel familiar with all applicable local electrical and mechanical codes. Refer to the National Electrical Code (NFPA 70). Failure to properly install and test this product can result in personal injury or equipment malfunction.
Step 1: Remove Bottom Cover
Remove the bottom enclosure cover screw, slide directly downward (1A) and then
pull directly away (1B).
1A
1B
Step 2: Mount Enclosure
Determine the mounting location for the VersAlarm™ I/O. Make sure the power outlet or receptacle is within five feet of the alarm panel for the pre- installed power cable. Hold the alarm up to the desired mounting location, mark the drill hole locations. Once marked, drill pilot holes for screws (not included) and use wall mount anchors (not included) if necessary. Place enclosure in mounting location, adjust until the pilot holes are lined up with the enclosure and fasten screws to secure the alarm panel in place.
Step 3: Power Cable and Float Switch
The alarm panel comes with a pre-installed power cable and alarm float switch. Refer to the instructions for the alarm float switch to determine the alarm activation level and for proper installation. If using the auxiliary contacts, see step 4 for wiring.
CAUTION: Do not connect power until installation/wiring is complete.
- Mount alarm float switch at alarm activation level
- Plug power cable into 120VAC receptacle
Step 4: Wiring
The diagram below shows the six terminals on the terminal block that consists of three pairs of connections.
- The pre-installed float switch is connected to terminals 1 and 2.
- Installing an auxiliary device to terminals 3 and 4 is optional.
- The pre-installed incoming power cable is connected to terminals 5 and 6, line (L1) in terminal 5 and neutral (N) in terminal 6.
- NEVER leave ground wire exposed inside the panel, use provided Wago connector for wire termination.
A SENSOR
B AUX
C POWER
Installing Wire into Wago Connector:
- Lift tab(s) upward.
- Insert wire(s) into slot.
- Press tab(s) downward.
- Make sure wire(s) are secured.
A TO OPEN WAGO
B TO CLOSE WAGO
Step 5: Install Bottom Cover
Line up the bottom enclosure cover with the grooves (5A), then slide directly
upward (5B) until it meets the top of the enclosure so the screw hole is lined
up and replace the screw at the bottom of enclosure.
5A
5B
Step 6: Power Alarm and Quick Test
After all wiring and installation steps have been completed, power the alarm by plugging the pre-installed power cable into a standard 120VAC wall outlet or power receptacle. Make sure the outlet is on a separate circuit breaker from any other device and not on a switched receptacle to maintain power integrity. Use the features list and diagram below to perform a quick test of the alarm to make sure it is working properly. Note: For complete wiring, installation instructions, or troubleshooting, refer to the user guide for this model by scanning QR code.
Included with Product
- (1) VersAlarm™ I/O alarm panel
- (2) Pre-installed cable grips
- (1) Pre-installed, male, 120VAC, 6-foot power cable
- (1) Pre-installed alarm float switch
- (1) RubberLox™ pipe clamp
- (1) Wago connector
Customer Support
Online
alderonind.com
Email
info@alderonind.com
QR Code
Scan code for full product details
Specifications
VersAlarm™ I/O
Primary Power: 120VAC, 50/60Hz
Power: 2.64 Watts maximum (alarm condition)
Certifications: FCC Part 15 (US/Canada), CSA (US/Canada)
Auxiliary Contacts: 24VDC @ 0.5 Amps maximum
Enclosure: Outdoor, rated Type 3R
FCC Part 15: NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: increase the separation between the equipment and receiver, connect the equipment into an outlet on a circuit different from that to which the receiver is connected, consult the dealer or an experienced radio/TV technician for help. Caution: changes / modifications not approved by Alderon Industries could void the user’s authority to operate the equipment.
Altra™ Alarm Float Switch
Electrical: 5 Amp, 120/240VAC
Operating Temperature: 0 – 140° F
Cable Type: SJOOW (UL/CSA), flexible, 18 gauge,
2-conductor, water/oil resistant
Float Housing: Polypropylene
Switching Differential: 20° total (narrow angle) and 90° total (wide
angle)
Switching Configuration: Single Pole, Single Throw (Normally Open or
Normally Closed)
Certifications: CSA (US and Canada)
VersAlarm™ I/O – Features
1 Power On Indicator – Green LED illuminates enclosure cover
2 Alarm Beacon – Red LEDs illuminate enclosure cover
3 Alarm Buzzer – Annunciates to indicate an alarm condition
4 Test/Silence Pushbutton – Activates alarm, silences alarm buzzer
5 Sensor Input – Terminals for the alarm float switch connection
6 Auxiliary Contacts – Interface with external device, 24VDC @ 0.5A
maximum
7 Power Mains Input – Terminals for line (L1) and neutral (N), 120VAC
8 Power Indicator Turn Off – Flip switch down to turn off green power LED
9 QR Code – Scan code for additional product information (alderonind.com)
10 Cable Grips (not shown) – Pre-installed for easy installation
11 6-Foot Power Cable (not shown) – Pre-installed, male, 120VAC
12 Alarm Float Switch/Sensor (not shown) – Pre-installed for easy
installation
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>