PHILIPS RC132V Emergency Coreline Panel Instruction Manual

June 9, 2024
Philips

PHILIPS RC132V Emergency Coreline Panel

PHILIPS-RC132V-Emergency-Coreline-Panel-PRODUCT

WHAT IN THE BOX

PHILIPS-RC132V-Emergency-Coreline-Panel-FIG-1

FEATURES

PHILIPS-RC132V-Emergency-Coreline-Panel-FIG-2

Product info label

Life time table

L80 100K hrs| 3100-3600 lm
L75 100K hrs| 4300 lm

 |

Lumen (lm)

| CCT (K)|

P(W)

|

L x W x H (mm)

|

H1/H2

| Weight (Kg)|

IP

| Energy efficancy class of the light source
---|---|---|---|---|---|---|---|---
RC132V G5 36S/840 PSD W60L60 OC ELB3| 3600| 4000| 34| 595 x 595 x 69| 37/11| 3.2| IP20/OPT IP44| D
RC132V G5 36S/840 PSU W60L60 OC ELB3| 3600| 4000| 34| 595 x 595 x 69| 37/11| 3.2| IP20/OPT IP44| D
RC132V G5 36S/840 PSU W30L120 OC ELB3| 3600| 4000| 34| 1195 x 295 x 69| 37/11| 3.3| IP20/OPT IP44| D
RC132V G5 36S/840 PSD W30L120 OC ELB3| 3600| 4000| 34| 1195 x 295 x 69| 37/11| 3.3| IP20/OPT IP44| D
RC132V G5 31_36_43S/840 PSD W60L60OCELB3| 3100/3600/4300| 4000| 40| 595 x 595 x 69| 37/11| 3.2| IP20/OPT IP44| D
RC132V G5 36S/840 PSD W60L60 OCTP(a)ELB3| 3600| 4000| 34| 595 x 595 x 69| 37/11| 3.2| IP20/OPT IP44| D
RC132V G5 36S/840 PSU W60L60 NOC ELB3| 3600| 4000| 34| 595 x 595 x 69| 36/10| 2.9| IP20/OPT IP44| D
RC132V G5 34S/830 PSD W60L60 OC ELB3| 3400| 3000| 34| 595 x 595 x 69| 37/11| 3.2| IP20/OPT IP44| D
RC132V G5 36S/840 PSU W30L120 NOC ELB3| 3600| 4000| 34| 1195 x 295 x 69| 36/10| 3.0| IP20/OPT IP44| D
RC133V G5 36S/840 PSED W62L62 OC| 3600| 4000| 30| 620 x 620 x 73| 37/11| 2.5| IP20/OPT IP44| D
RC133V G5 34S/830 PSED W62L62 OC| 3400| 3000| 30| 620 x 620 x 73| 37/11| 2.5| IP20/OPT IP44| D
RC132V G5 36S/840 PSU W60L60 NOC ELB3W4| 3600| 4000| 34| 595 x 595 x 69| 36/10| 2.9| IP20/OPT IP44| D
RC132V G5 36S/840 PSU W60L60 OC ELB3W4| 3600| 4000| 34| 595 x 595 x 69| 37/11| 3.2| IP20/OPT IP44| D
RC132V G5 36S/840 PSD W60L60 OC ELB3W4W2| 3600| 4000| 34| 595 x 595 x 69| 37/11| 3.2| IP20/OPT IP44| D
RC132V G5 36S/840 PSU W30L120 NOC ELB3W4| 3600| 4000| 34| 1195 x 295 x 69| 36/10| 3.0| IP20/OPT IP44| D
RC132V G5 36S/840 PSU W30L120 OC ELB3 W4| 3600| 4000| 34| 1195 x 295 x 69| 37/11| 3.3| IP20/OPT IP44| D
RC132V G5 36S/840 PSD W30L120OCELB3W4W2| 3600| 4000| 34| 595 x 595 x 69| 37/11| 3.3| IP20/OPT IP44| D
RC132V G5 31_36_43S/840PSD6060OCELB3W4W2| 3100/3600/4300| 4000| 40| 595 x 595 x 69| 37/11| 3.2| IP20/OPT IP44| D
 |

Lumen (lm)

|

CCT (K)

|

P (W)

|

L x W x H (mm)

|

H1/H2 (mm)

|

Weight (Kg)

|

IP

| Energy efficancy class of the light source
---|---|---|---|---|---|---|---|---
RC132V G5 36S/840 WIA W60L60 OC ELB3| 3600| 4000| 34| 595 x 595 x 69| 37/11| 3.3| IP20/OPT IP44| D
RC132V G5 36S/840 WIA W60L60 NOC ELB3| 3600| 4000| 34| 595 x 595 x 69| 36/10| 3.0| IP20/OPT IP44| D
RC132V G5 36S/840 WIA W30L120 OC ELB3| 3600| 4000| 34| 1195 x 295 x 69| 37/11| 3.5| IP20/OPT IP44| D
RC132V G5 43S/840 WIA W60L60 NOC ELB3| 4300| 4000| 34| 595 x 595 x 69| 36/10| 3.0| IP20/OPT IP44| D
RC132V G5 36S/840 WIA W60L60 NOC ELB3 W4| 3600| 4000| 34| 595 x 595 x 69| 36/10| 3.0| IP20/OPT IP44| D
RC132V G5 36S/840 WIA W60L60 OC ELB3 W4| 3600| 4000| 34| 595 x 595 x 69| 37/11| 3.3| IP20/OPT IP44| D
RC132V G5 36S/840 WIA W30L120 OC ELB3 W4| 3600| 4000| 34| 1195 x 295 x 69| 37/11| 3.5| IP20/OPT IP44| D
RC132V G5 43S/840 WIA W60L60 NOC ELB3 W4| 4300| 4000| 34| 595 x 595 x 69| 36/10| 3.0| IP20/OPT IP44| D
RC132V G5 43S/840 WIA W60L60 OC ELB3| 4300| 4000| 34| 595 x 595 x 69| 37/11| 3.3| IP20/OPT IP44| D
RC132V G5 36/840 WIA W60L60 OC ELB3 TP(a)| 3600| 4000| 34| 595 x 595 x 69| 37/11| 3.3| IP20/OPT IP44| D
RC132V G5 43S/840 WIA W60L60 OC ELB3 W4| 4300| 4000| 34| 595 x 595 x 69| 37/11| 3.3| IP20/OPT IP44| D
RC133V G5 43S/865 PSED W62L62 OC| 4300| 6500| 37| 620 x 620 x 73| 37/11| 2.5| IP20/OPT IP44| D
RC132V G5 43S/840 SIA W60L60 OC IA4| 4300| 4000| 43| 595 x 595 x 73| 37/11| 2.5| IP20| D
RC132V G5 40S/830 SIA W60L60 OC IA4| 4300| 3000| 43| 595 x 595 x 73| 37/11| 2.5| IP20| D

DIMENSION

PHILIPS-RC132V-Emergency-Coreline-Panel-FIG-3 PHILIPS-RC132V-Emergency-Coreline-Panel-FIG-4 PHILIPS-RC132V-Emergency-Coreline-Panel-FIG-5

Available as accessory (Need to purchase separately)

Suspension set (Not for PSD with EL)

  • 911401861284 RC132Z G5 SME-3 (PSU/WIA/SIA)
  • 911401861384 RC132Z G5 SME-4 WH (PSD/PSED)

Surface mounted set

  • 911401860884 RC132Z G5 SMB W60L60
  • 911401860984 RC132Z G5 SMB W62L62
  • 911401861084 RC132Z G5 SMB W30L120

Plaster ceiling set

  • 911401861184
  • RC132Z G5 SMB-PLC

Safety Cable

  • 911401892080 RC132Z SC

Quick connectors

PSU/PSD/PSED/WIA

PHILIPS-RC132V-Emergency-Coreline-Panel-FIG-10

PSU/WIA

PHILIPS-RC132V-Emergency-Coreline-Panel-FIG-11

PSD

PHILIPS-RC132V-Emergency-Coreline-Panel-FIG-12

Versions with wieland connector (W4, W4W2) ELB3

Wieland (W4, W4/W2) ELB3 versions

PHILIPS-RC132V-Emergency-Coreline-Panel-FIG-13

PSED version

PHILIPS-RC132V-Emergency-Coreline-Panel-FIG-14

SIA version

PHILIPS-RC132V-Emergency-Coreline-Panel-FIG-15

WARNING: If the external f exible cable or cord of this luminaire is damaged, it shall be replaced by a special cord or cord exclusively available from the manufacturer or his service agent.

VPC – Visible Profile Ceiling/ Lay-in mounting

PHILIPS-RC132V-Emergency-Coreline-Panel-FIG-17

Safety cable

PHILIPS-RC132V-Emergency-Coreline-Panel-FIG-18

PCV – plaster ceiling version (IK02)

Optional with 911401861184 RC132Z G5 SMB-PLC

Install safety cable (Optional)

PHILIPS-RC132V-Emergency-Coreline-Panel-FIG-19

PHILIPS-RC132V-Emergency-Coreline-Panel-FIG-20

PHILIPS-RC132V-Emergency-Coreline-Panel-FIG-21

Surface mounted

Optional with: 911401860884 RC132Z G5 SMB W60L60, 911401860984 RC132Z G5 SMB W62L62, 911401861084 RC132Z G5 SMB W30L120

PHILIPS-RC132V-Emergency-Coreline-Panel-FIG-24

  • For Emergency version (ELB)
  • For the indicator LED – additional hole is necessary

Suspension set (not for ELB)

Optional with: 911401861284 RC132Z G5 SME-3 WH (PSU/WIA), 911401861384 RC132Z G5 SME-4 WH (PSD/ PSED)

PSU/WIA

PSD/PSED

PSU/WIA

PSD/PSED

PSD/PSED

PSD/PSED

PHILIPS-RC132V-Emergency-Coreline-Panel-FIG-32

PHILIPS-RC132V-Emergency-Coreline-Panel-FIG-33

WARNING

PHILIPS-RC132V-Emergency-Coreline-Panel-FIG-34

Multi Lumen

PSD

Lumen selection
Lumen (3000K)| Lumen (4000K)| Iout| Pin1| Pin2
2900| 3100| 0,65A| OFF| OFF
3400| 3600| 0,75A| ON| OFF
4000| 4300| 0,9A| OFF| ON
Do not use| 1,05A| ON| ON

Battery replacement

PHILIPS-RC132V-Emergency-Coreline-Panel-FIG-36

Indicator LED

Emergency Luminaire

  • In case a self-contained emergency driver has been added, this is how to set the timers (IEC62034 (S6.3.2):

BASIC version: No timers available, only manual testing through the test button.

Polar diagrams for ELB3 versions

PHILIPS-RC132V-Emergency-Coreline-Panel-FIG-38

Polar diagram for PSED version: The luminaire is working on 15% of the normal mode of the luminous flux by DC supply

W62L62 OC

Charge time

PHILIPS-RC132V-Emergency-Coreline-Panel-FIG-40

Lifetime

  • The batteries have a life time expectancy of 4 years when maintained properly. Replace after that timel

Automatic emergency time selection

  • During automatic detection, the indicator LED willlight up with short green flashes.
  • Between minimum 6 and maximum 30 seconds the TrustSight driver will set the battery type (number of ce and will set the emergency output power accordingly.

After that, the system is defined and fully operational. The battery type definition has influence on the performance during the self-test and on the battery charge method. When the automatic battery detection process is disrupted e.g. by switching off the permanent mains, the detection process is stopped and the TrustSight emergency driver will go into emergency mode with the lowest output power. At a next power up, the automatic detection process will start again.

Periodic testing

Periodic tests of emergency lighting luminaires must be performed according to EN50172 clause 7.2.3 and 72.4. Switch on in the emergency mode each month by simulation of a failure of the supply to the normal lighting for a period sufficient to ensure that each lamp is illuminated. Twice per year, each luminaire shall be tested for its full rated duration (at least 3hrs). For more information please consult the TrustSight Gen 3 Design in guide. The latest version is available online.

LED indicator status

PHILIPS-RC132V-Emergency-Coreline-Panel-FIG-41

WARNING

  • The luminaire shall be installed by qualified electrician and wired in accordance with the latest IEE electrical regulations or the national requirements.
  • The light source of this luminaire is not replaceable; when the light source reaches its end of life the whole luminaire shall be replaced
  • During the installation or maintaining the luminaire please use gloves to avoid spots on the cover.

To remove dirt and spots use the following

  • Dust: use micro fiber cloths only.
  • Fingerprints, etc.: use cleaner for synthetic materials with antistatic properties.
  • Luminaires not suitable for covering with thermally insulating material.
  • For controllable luminaires, the classification of the insulation between LV supply and control conductors shall be basic insulation at least.
  • Luminaires must not be used or stored in corrosive environment where hazardous materials such as Sulphur,Chlorine, Phthalates, etc., are present.

Battery Unit (LFP)

Manufacturer: Philips
Unit: TrustSight 3.2V 3cell

4500mAh battery LFP

Technology:| Lithium-Ion
Luminous flux:| 250 lm
Capacity:| 4500 mAh
Power:| 2W
Duration:| 3h
Nominal voltage:| 3.2V

WIGHT

  PSU PSD WIA PSED/SIA
  Electrical characteristics
Imax(A) 16 18,7 4,8 20,4
Tref (us) 200 288 56 195
MCB No. Of luminaires max.
B-10 A 13 7 32 16
B-16 A 21 12 50 24
C-10 A 18 12 52 25
C-16 A 30 19 85 41

SCAN

PHILIPS-RC132V-Emergency-Coreline-Panel-FIG-43

PHILIPS-RC132V-Emergency-Coreline-Panel-FIG-44

To get an overview of all spare parts for a luminaire, please refer to detailed instructions in the service manual available via the Signify Service tag apps (Android and iOS).

Disconnect before servicing

  • Luminaire has basic insulation between Low Voltage supply and control conductors.

The control gear and/or the external flexible cable contained in this luminaire shall only be replaced by the manufacturer or his service agent or a similar qualified person. The light source contained in this luminaire is not replaceable, in case of damage replace the luminaire.

Storage, installation, use, operation and maintenance of the products needs to be performed exactly according the instructions in this manual and/or other instructions as may be provided by us to guarantee safe use of the product over its entire lifetime. Failure to adhere to these instructions will invalidate your entitlement to warranty. Bolts with indication of torque strength on the drawing need to be tightened using a calibrated torque wrench. Pre-assembled bolts need to be retightened again to the required torque specification to assure maximum strength over lifetime.

This product contains a light source of energy efficiency class: see table or label.

Zhaga-D4i and SR certified compatibility:  For Zhaga-D4i/SR-Certified based luminaires only Zhaga-D4i/SR-Certified components/sensors are to be used (see also: https://www.zhagastandard.org/products / https://www.lighting.philips.co.uk/oem-emea/products/driving-connected- lighting). The functional compatibility of two SR-certified and/or Zhaga-D4i controllers/sensors to be used in combination, as well as the override possibility of any line-switch function used in an SR-based/Zhaga-D4i luminaire, is to be released by the master controller/sensor supplier. If using a NEMA 7-pin socket on an SR-based luminaire, a full system verification is required. Not following this advice can/will cause risk of damage and non- compliance for which Signify cannot take any responsibility.

© 2023 Signify Holding

All rights reserved. This document contains information relating to the product portfolio of Signify which information may be subject to change. No representation or warranty as to the accuracy or completeness of the information included herein is given and any liability for any action in reliance thereon is disclaimed. The information presented in this document is not intended as any commercial offer and does not form part of any quotation or contract. Philips and the Philips Shield Emblem are registered trademarks of Koninklijke Philips N.V.. All other trademarks are owned by Signify Holding or their respective owners.

Signify Holding
The Netherlands

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)