EQK EARC6RE1A Electronic Window Air Conditioner User Manual
- June 4, 2024
- EQK
Table of Contents
EARC6RE1A Electronic Window Air Conditioner
Electronic Window Air Conditioner
User Manual
Model : EARC5RD1A / EARC6RE1A / EARC6RSE1A
Thank you very much for purchasing our air conditioner.Please read this
owner`s manualcarefully before using your air conditioner.
IMPORT ANT SAFETY INSTRUCTIONS
1
INTRODUCTION TO REFRIGERANTS R32
2
ELECTRICAL REQUIREMENTS
3
PACKINGLIST
4
INSTALLATION & ASSEMBLY INSTRUCTIONS
5
USING YOURAIR CONDITIONER
9
CAREAND CLEANING
12
TROUBLESHOOTING
13
THANK YOU
Congratulations on your purchase and welcome to the
Family.
Your new
Air Conditioner combines high-efficiency operation with
portable convenience.
By following the operating and care instructions in this manual,your air conditioner will
provide you with many years of reliable service.
Please visit our website www.emersonquietkool.com
For any questions or Technical Support, please contact us by mail info@geektechnology.com or by phone 1-844 -801-8880.
below:
FCC Caution. This device complies with part 15 of the FCC Rules. Operation is
subject to the following two conditions: (1) This device may not cause harmful
interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation. Any Changes or
modifications not expressly approved by the party responsible for compliance
could void the user’s authority to operate the equipment.
1
INTRODUCTION TO REFRIGERANTS R32(Only for R32 Model)
The refrigerants used for air conditioners are environmentally friendly
hydrocarbons R32. This kind of erant is combustible and odorless. Moreover, it
can burn and explode under certain condition. However, there will be no risk
of burning and explosion if you comply with the following table to install
your air conditioner in a room with an appropriate area and use it correctly.
Compared with ordinary refrigerants, Refrigerant R32 is environmentally
friendly and do not destroy the ozone sphere and that its value of greenhouse
effect is also very low.
Room area requests for air conditioner with Refrigerant R32
Refrigerant R32
Capacity(Btu) 9K 12K 18K 24K
Room Area Above 4m2 Above 4m2 Above 15m2 Above 25m2
Warnings
Please read the manual before installation, using, maintenance.
Do not use means to accelerate the defrosting process or to clean, other than
those recommended by the manufacturer.
Do not pierce or burn the appliance.
The appliance shall be stored in a room without continuously operating sources
(for example: open flames, an operating ignition gas appliance or an operating
electric heater.)
Please contact the nearest after-sale service center when maintenance is
necessary. At the time of maintenance, the maintenance personnel must strictly
comply with the Operation Manual provided by the corresponding manufacturer
and any non-professional is prohibited to maintain the air conditioner.
The handling, installation, storage, servicing and disposal must comply with
the provisions of gas-related national laws and regulations, and also national
wiring regulation.
It is necessary to clear away the refrigerant in the system when maintaining
or scrapping an air conditioner. Be aware that refrigerants may not contain an
odour.
This appliance is not intended for use by persons (including children) with
reduced physical, sensory or mental capabilities, or supervision or
instruction concerning use of the appliance by a person responsible for their
safety. Children should be supervised to ensure that they do not play with the
appliance. Unit operation limits: Outdoor side 61~110 , 80%RH; indoor side
61~90 , 80%RH.
2
0-8 amps 10-a mp
3
4
6 84
FIG. 1
STOOL OFFSET SILL
INTERIOR WALL
EXTERIOR WALL
23″ to 36″ 584 mm to 914 mm
14 1/2″ min (368mm)
Head
5
5
6
7 (Suggest to keep a downward
angle, to let accumulated rain water to drain out,
from back side of the unit bottom.)
8
6
FIG. 13
Head FIG. 9
9 10
FIG. 10
FIG. 11
FIG. 12
4 FIG. 14
7
INSTALLATION & ASSEMBLY INSTRUCTIONS Important Considerations
Before installing the appliance, you must read the manual carefully to get the
safety information and notes. Unit refrigerant charge amount: refer to unit
name plate marking. A leak test must be done after the installation is
completed. It is a must to do the safety inspection before maintaining or
repairing an air conditioner using combustible refrigerant in order to ensure
that the fire risk is reduced to minimum. It is necessary to operate the
machine under a controlled procedure in order to ensure that any risk arising
from the combustible gas or vapor during the operation is reduced to minimum.
Introduction to Refrigerants R32(Only for R32 Model)
1. Site Safety
Open Flames Prohibited
2. Operation Safety
Open Flames Prohibited
Ventilation Necessary
Mind Static Electricity Must Wear Protective Clothing and anti-static gloves
3. Installation Safety
Refrigerant Leak Detector Appropriate Installation Location
Don’t use mobile phone
The left picture is the schematic diagram of a refrigerant leak detector.
Please note that: 1. The installation site should be in a well-ventilated
condition. 2. The sites for installing and maintaining an air conditioner
using Refrigerant R32 should be free from open fire
or welding, smoking, drying oven or any other heat source higher than 548
which easily produces open fire. 3. When installing an air conditioner, it is
necessary to take appropriate anti-static measures such as wear
anti-static clothing and/or gloves. 4. It is necessary to choose the site
convenient for installation or maintenance wherein the air inlets and outlets
of
the indoor and outdoor units should be not surrounded by obstacles or close to
any heat source or combustible and/or explosive environment. 5. If the indoor
unit suffers refrigerant leak during the installation, all the personnel
should go out till the refrigerant leaks completely for 15 minutes. If the
product is damaged, it is a must to carry such damaged product back to the
maintenance station and it is prohibited to weld the refrigerant pipe or
conduct other operations on the user’s site. 6. It is necessary to choose the
place where the inlet and outlet air of the indoor unit is even. 7. It is
necessary to avoid the places where there are other electrical products, power
switch plugs and sockets, kitchen cabinet, bed, sofa and other valuables right
under the lines on two sides of the indoor unit, and also prevent mechanical
damage from occurring.
8
1. Digital Display: Shows the set temperature. Operation modes are: Cool, Dry, Fan, and Auto. Time is displayed using the timer setting.
2. Mode Button: Press the mode button to cycle
through the various modes: Cool, Dry, Fan and
Auto.
Cool Mode: The cooling function allows the air
conditioner to cool the room and at the same time
reduces humidity. Press the MODE button to
1
activate the cooling function. To optimize this
function adjust the temperature by pressing the up
and down arrows and the speed by pressing the
Fan Speed button.
Dry Mode: This function reduces the humidity of
the air to make the room more comfortable. Press
MODE button to set the DRY mode. An automatic
function of alternating cooling cycles and air fan
is activated.
9
2
Fan Mode: This mode will only circulate the air.
Press MODE button to select FAN MODE.
Pressing the FAN SPEED button allows you to
change the fan speed setting from HI, MED, and
LO. If using the remote control, it will store the fan
3
speed setting of the previous use.
Auto Mode: In AUTO mode the unit automatically
8
4
chooses the fan speed and the mode of operation
(COOL, DRY, or FAN). In this mode the fan speed
and the temperature are set automatically
7
5
according to the room temperature (Room
temperature is determined by the temperature
sensor located in the indoor unit.).
6
and Button: Use these buttons on the
control panel and remote to increase or decrease
the Set Temperature or Timer.
Temperature range: 61 ~88 or 16 ~31 .
4. Sleep Button: Press the SLEEP button, all of the display lights will turn off after a while, but the Sleep light is always on. In SLEEP mode, the air conditioner will automatically adjust the temperature and fan speed to make the room more comfortable during the night. The set temperature will automatically raise every 30-60 minutes, and at most change sixtimes until the set temperature is 81 or 82 .
9
5. Eco Button: When the unit is in ECO mode, the light will turn on. In ECO mode, the unit will turn-off once the room is cooled to the user set temperature. The fan will also be off at this point. The unit will turn back on when the room temperature rises above the user set temperature. Before the compressor stars, the fan motor will run for a while, then it will stop for a while-and will repeat to provide a much more comfortable-feeling and save energy.
9. Fan Speed Button: Press the FAN SPEED button to select the fan speed. In
COOL MODE you can choose the following settings: HI, MED, LO, or AUTO. In FAN
MODE you can choose from HI, MED, and LO.
10.Directional Louvers:Use the horizontal wheels to control horizontal airflow
and the air deflectors to control vertical airflow.
6. Power Button: Turn the air conditioner on and off.
7. Filter Button: The Filter Check light will only turn on as a reminder to
clean the filter after the fan motor has been in operation for a total of 500
hours. To turn the light off, press the Filter Check button.
air deflector horizontal wheel air deflector
8. Timer Button: Use these buttons on the control
panel and remote to set the Timer.
Timer Off: The timed stop is programmed by
pressing the TIMER button. Set the stop time by
pressing the button
or
until your
desired stop time is displayed, then press TIMER
button again.
Timer On: When the unit is off, press TIMER
button first, set the temperature with pressing
the button
or
. Press TIMER button
a second time, set the stop time with pressing the
button
or
. Press TIMER button a
third time, confirm your settings and stop time.
The display will show the time your machine will
automatically turn on.
Note: It can be set to automatically turn off or on in 0.5-24 hours. Each press of the buttons will increase or decrease the timer. The Timer can be set in 0.5 hours increment below 10 hours and 1 hour increment for 10 hours or above. The SET light will turn on while setting. To cancel the set function, press the TIMER button again.
10
5. TURBO: When the remote is ON, press the button to active the TURBO function, under AUTO/COOL/FAN/HEAT mode.
1
2
3
4
5
3
6
9
7
8
1. POWER: Turn the air conditioner on and off.
2. MODE: Press the button to select the mode of operation, AUTO, COOL, DRY,
FAN, HEAT. Note: The HEAT mode is only for some heating models.
3. and : Use these buttons to increase or decrease the Set Temperature or
Timer. Temperature range: 61 ~88 or 16 ~31 .
6. ECO: When the unit is in ECO mode, the light will turn on. In ECO mode, the unit will turn-off once the room is cooled to the user set temperature. The unit will turn back on when the room temperature rises above the user set temperature. Before the compressor stars, the fan motor will keep running for a while and stop for a while-and again, to provide much more comfortable feeling, and save the energy.
7. TIMER: Use these buttons on the control panel
and remote to set the Timer.
Timer Off: The timed stop is programmed by
pressing TIMER button. Set the rest time by
pressing the button
or
until the rest
time displayed is to your demand then press
TIMER button again.
Timer On: When the unit is off, press TIMER
button at the first time, set the temperature with
pressing the button
or
. Press TIMER
button at the second time, set the rest time with
pressing the button
or
. Press TIMER
button at the third time, confirm the setting, then
the rest time to next automatically switching-on
could be read on the display of the machine.
Note: It can be set to automatically turn off or on
in 0.5-24 hours. Each press of the
buttons will increase or decrease the timer. The
Timer can be set in 0.5 hours increment below
10 hours and 1 hour increment for 10 hours or
above. The SET light will turn on while setting.
To cancel the setted function, press the TIMER
button again.
4. SLEEP: Press the SLEEP button, all of the dis-
play lights will turn off after a while, but the sleep 8. FAN: Press the FAN SPEED button to choose
light is always on. In the mode, the airconditioner
the fan speed options. You can choose Hi, Med, Lo or auto speed in COOL or HEAT mode and
will automatically adjust the temperature and fan
choose Hi, Med, Lo in FAN mode.
speed to make the room more comfortable during
the night. The set temperature will automatically
change every 30-60 minutes and at most change 9. DISPLAY: To press the DISPLAY button, it can
six times until the set temperature is 81 or 82
switch off/on all lights or LED display.
for cooling and 75 or 76 for heating.
Battery Size: AAA – NOTE: Do not mix old and new batteries or different types of AAA batteries.. 11
15 FIG. 15
12
13
14
Emerson Quiet Kool Co. Ltd. 1275 Bloomfield Ave 16-141 Fairfield NJ 07004 USA
Toll Free 1-844-801-8880
Version Update–2021.5.0
A5 200g 128g
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>