HINKLEY 3419 Clarendon LED 30 inch Bronze Instruction Manual

June 9, 2024
HINKLEY

HINKLEY 3419 Clarendon LED 30 inch Bronze Instruction Manual
HINKLEY 3419 Clarendon LED 30 inch Bronze

Assembly Instructions

  1. Find a clear area in which you can work.
  2. Unpack fixture and glass from carton.
  3. Carefully review instructions prior to assembly

Construction of this fixture will be accomplished by first assembling the central body, then attaching the cage assembly, installing the mounting hardware, making all necessary electrical connections, hanging the fixture, then installing the glass.

  1. First secure both top stem (2) and lower stem (1) to the main fixture body (7)
  2. Next secure spider assembly (3) to top stem (2)
  3.  Secure cage (6) to spider assembly (3) using the 4provided screws (5)
  4.  Secure fixture loop (4) to the top of assembly
  5.  Fixture assembly is now complete follow IS-19 on page 2 for mounting instructions, and follow IS-18 on page 3 for wiring instructions.
    Assembly Instructions

SAFETY WARNING: READ WIRING AND GROUNDING INSTRUCTIONS (I.S. 18) AND ANY ADDITIONAL DIRECTIONS. TURN POWER SUPPLY OFF DURING INSTALLATION. IF NEW WIRING IS REQUIRED, CONSULT A QUALIFIED ELECTRICIAN OR LOCAL AUTHORITIES FOR CODE REQUIREMENTS.

Make electrical connections from supply wire to fixture lead wires. Refer to instruction sheet (I.S. 18) and follow all instructions to make all necessary wiring connections.
Assembly Instructions

hanging instructions

SAFETY WARNING: READ WIRING AND GROUNDING
INSTRUCTIONS (I.S. 18) AND ANY ADDITIONAL DIRECTIONS. TURN POWER SUPPLY OFF DURING INSTALLATION. IF NEW WIRING IS REQUIRED, CONSULT A QUALIFIED ELECTRICIAN OR LOCAL AUTHORITIES FOR CODE REQUIREMENTS.

  1. Shut off electrical current before starting. If the fixture you are replacing is turned on and off by a wall switch, simply turn the switch off. If not, remove the appropriate fuse (or open the circuit breakers) until the fixture is dead.

DO NOT restore current – either by fuse, breaker or switch – until the new fixture is completely wired and in plac

  1. Fasten mounting strap provided – see (1) to outlet box (A) with the two 8-32 screws (2) not  Drawing 1.
  2. Thread 2 – hex nuts (3a) and (3b) onto threaded tubing (4).
  3. Thread one end of threaded tubing (4) into loop (5) a minimum of 1/2’’ to 3/4’’. Tighten hex nut (3a) against loop (5) to lock loop in position.
  4. Thread other end of threaded tube (4) into mounting strap approximately 1/2’’.
  5. Slip canopy (B) over loop (5) and adjust height of loop so half of the threaded area on the loop is exposed – see Drawing 2 below. After loop height is adjusted, tighten hex nut (3b) up against mounting strap, tighten against mounting strap to lock loop and threaded tube in position.
  6. Remove mounting strap (1) from junction box (A), and thread third hex nut (3c) onto end of threaded tube (4) above the mounting strap, tighten against mounting strap to lock assembly in position.
  7. Remount mounting strap to junction box
  8.  Taking the chain, determine the length you require to hang the fixture.
  9. Attach one end of the chain to the top loop of the fixture.
  10. Now slip loop collar (6) and canopy (B) onto chain. — see Drawing 2
  11. Attach other end of chain to loop (5). Get assistance for this step since fixture may be heavy and difficult to hold while attaching the chain.
  12. Unwrap fixture lead wire and ground wire and weave them up through the chain.
  13. Slip fixture lead wire and ground wire through center of loop (5).
  14. Connect ground wire to mounting strap (1) using green ground screw (GS).
  15. Make electrical connections from supply wire to fixture lead wires. Refer to instruction sheet (I.S. 18) and follow all instructions to make all necessary wiring connections.
  16. Slip canopy up firmly against the ceiling and secure by turning the threaded collar (6) on loop (5) until tight.
    Assembly Instructions

wiring grounding instructions

SAFETY WARNING: READ WIRING AND GROUNDING INSTRUCTIONS (IS 18) AND ANY ADDITIONAL DIRECTIONS. TURN POWER SUPPLY OFF DURING INSTALLATION. IF NEW
WIRING IS RE QUIRED, CONSULT A QUALIFIED ELECTRICIAN OR LOCAL AUTHORITIES FOR CODE REQUIREMENTS

wiring instructions

Indoor Fixtures

  1. Connect positive supply wire (A) (typically black or the smooth, unmarked side of the two-conductor cord) to positive fixture lead (B) with appropriately sized twist on connector – see Drawings 1 or 2.
  2. Connect negative supply wire (C) (typically white or the ribbed, marked side of the two-conductor cord) to negative fixture lead (D).
  3. Please refer to the grounding instructions below to complete all electrical connections

Outdoor Fixtures

  1. Connect positive supply wire (A) (typically black or the smooth unmarked side of the two-conductor cord) to positive fixture lead (B)
    with appropriately sized twist on connector — see Drawings 2 or 3.

  2. Connect negative supply wire (C) (typically white or the ribbed, marked side of the two-conductor cord) to negative fixture lead (D).

  3. Cover open end of connectors with silicone sealant to form a watertight seal. If installing a wall mount fixture, use caulk to seal gaps between the fixture mounting plate (backplate) and the wall. This will help prevent water from entering the outlet box. If the wall surface is lap siding, use caulk and a fixture mounting platform specially.

  4. Please refer to the grounding instructions below to complete all electrical connections.

Flush Mount Fixtures

For positive grounding in a 3-wire electrical system, fasten the fixture
ground wire (E) (typically copper or green plastic coated) to the fixture mounting strap (M) with the ground screw (S) – see Drawing 1.
Note: On straps for screw supported fixtures, first install the two mounting screws in strap. Any remaining tapped hole may be used for the ground screw.

Chain Hung Fixtures

Loop fixture ground wire (E) (typically copper or green plastic coated) under the head of the ground screw (S) on fixture mounting strap (M) and connect to the loose end of the fixture ground wire directly to the ground wire of the building system with appropriately sized twist-on connectors – see Drawing 2.


Post-Mount Fixtures
Connect fixture ground wire (E) (typically copper or green plastic coated)
to power supply ground with appropriately sized twist-on connector inside post. Cover open end of connector with silicone sealant to form a watertight seal – see Drawing 3.

HINKLEY Logo

Documents / Resources

| HINKLEY 3419 Clarendon LED 30 inch Bronze [pdf] Instruction Manual
3419, Clarendon LED 30 inch Bronze, LED 30 inch Bronze, Clarendon Bronze, Bronze
---|---

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals