KORG NTS-2 Nu Tekt Oscilloscope Kit Owner’s Manual
- June 4, 2024
- KORG
Table of Contents
- Introduction
- Main features of this unit
- Part names and functions
- Making connections and turning on the power
- Four operating modes
- Basic operations
- Oscilloscope mode (SCOPE)
- Function generator mode (WAVE)
- Spectrum analyzer mode (FFT)
- Tuner mode (TUNER)
- Global mode
- Specifications
- Documents / Resources
NTS-2 oscilloscope kit
MULTIFUNCTIONAL UTILITY KIT
Owner’s Manual
Introduction
Thank you for purchasing the Multifunctional Utility Kit for the Nu: Text NTS-2 Oscilloscope Kit. To help you get the most out of your purchase, please read this manual carefully.
Main features of this unit
This product is an assembly kit that you can use to build a digital oscilloscope. Aside from letting you view audio output waveforms and CV signals, this oscilloscope functions as a spectrum analyzer, offers a built-in tuner for tuning analog synthesizers, and lets you output LFO, CV, and other signals with its function generator.
Part names and functions
-
Mode button
Use this button to switch between operating modes. Each time you press the button, the mode changes.
a. Oscilloscope (SCOPE)
b. Function generator (WAVE)
c. Spectrum analyzer (FFT)
d. Tuner (TUNER)
e. Global (GLOBAL) -
Buttons 1–4
The functions assigned to these buttons differ, depending on the operating mode. -
START/STOP button
Starts and stops measurement. In function generator mode, this is also used to output waveforms to an external device. -
Value knob
Press to select a sub-menu, and turn to edit the selected parameter. -
INPUT 1, 2 jacks
Connect a stereo (or mono) mini cable here to input the signal you wish to measure. This lets you monitor the audio output from your musical instrument or input a CV signal. -
THRU 1, 2 jacks
Used as a thru for the signal input from the INPUT 1 and 2 jacks. -
OUTPUT 1, 2 jacks
Outputs the function generator signal. Connect these jacks to your device with monaural mini plugs. -
USB (Type-C) port
Use the included USB cable to connect this unit to the USB port on your computer or to a commercially available USB standards-compliant AC adapter (at least 5 V DC 550 mA). -
Power button
Turns the power on and off. Hold this button down for approximately one second to turn the power off. -
Battery compartment
Making connections and turning on the power
Use the included USB cable to connect this unit to the USB port on your
computer or to a commercially available USB standards-compliant AC adapter (at
least 5 V DC 550 mA).
Make sure to use the included USB cable.
Use a cable that’s no more than 3 m long when connecting your peripherals to
this unit.
Make sure to use an AC adapter that’s compliant with USB 2.0 standards. Note
that some standards-compliant USB AC adapters might not operate correctly.
Turning the power on/off
Long-press the power button to turn on the unit.
Long-press the power button again to turn the unit off.
Auto power-off function
The Nu: Text NTS-2 features an auto power-off function that automatically
turns the unit off after one hour has elapsed without the knob, switches,
buttons or other controls being operated. The auto power-off function is
enabled by factory default. Auto power-off can be disabled using the steps
below.
- Use the mode button to enter global mode.
- Press button 4 (SETTINGS: Power) a number of times to select “Auto Power Off(USB)” or “Auto Power Off(Battery)”.
- Turn the value knob to change the value to “infinite”.
Four operating modes
Oscilloscope mode (SCOPE)
You can view the waveforms from up to four input sources. The functions below
are assigned to buttons 1–4.
- DISPLAY: Switches between input signals.
- VERTICAL: Sets the display range for the vertical screen direction (voltage).
- HORIZONTAL: Sets the display range for the horizontal screen direction (time).
- TRIGGER: Sets that change in input signal causes the display to update.
Function generator mode (WAVE)
In this mode, signal is output from the OUTPUT 1 and 2 jacks. These outputs
can be used even while an input signal is being received. You can use the
START/STOP button to turn the waveform output on/off, continuously output the
waveform by holding down the button, or output only one cycle of the waveform
(one-shot) by just pressing the button. The functions below are assigned to
buttons 1–4.
- CATEGORY: Selects the waveform for OUTPUT 2, sets the level and so forth.
- EDIT: Configures the detailed settings for the OUTPUT 2 waveform.
- CATEGORY: Selects the waveform for OUTPUT 1, sets the level and so forth.
- EDIT: Configures the detailed settings for the OUTPUT 1 waveform.
Spectrum analyzer mode (FFT)
This mode lets you observe the frequency characteristics of the input signal,
by using a spectrum analyzer that employs an FFT (fast Fourier transform)
algorithm. The functions below are assigned to buttons 1–4.
- INPUT: Switches between input signals.
- VERTICAL: Sets the display range for the vertical screen direction (voltage).
- HORIZONTAL: Sets the display range for the horizontal screen direction (time).
- TRIGGER: Sets that change in input signal causes the display to update. Normally, this is set to AUTO.
Tuner mode (TUNER)
This mode measures the pitch of the input signal from the oscillator of an
analog synthesizer or another source. You can select between a horizontal
meter and a needle-type (VU) meter view. The functions below are assigned to
buttons 1–4.
- DISPLAY: Selects the tuner display mode.
- INPUT: Switches between input signals to measure.
- CALIB: Adjusts the pitch lower or higher than the reference pitch of A=440 Hz. You can adjust the pitch within a range of 410–480 Hz.
- SCOPE: Switches the oscilloscope display on/off.
Basic operations
- Each time you press buttons 1–4, the parameter assigned to the button in question changes one at a time and is shown in the popup screen in the display.
- Once the desired parameter is shown, turn the value knob to edit the value.
- Measurement starts/stops with each press of the START/STOP button.
This product is a multi-tool intended for use with musical instruments. Do not use this product for anything under than its intended purpose, such as for calibrating measurement devices and so on.
Oscilloscope mode (SCOPE)
Oscilloscope mode lets you monitor the input signals coming from the four
input sources (INPUT 1, 2 L/R).
Use VERTICAL to set the voltage range for the vertical screen direction. For
example, a “5V” setting will display a 5 V voltage for each mark on the
vertical axis. Use HORIZONTAL to set the time scale in the horizontal screen
direction.
Use the DISPLAY setting to select the inputs shown on the oscilloscope,
display multiple inputs separately or stacked on top of each other, or to
display two inputs as an image for comparing two different signals. To compare
two signals with each other, set the vertical and horizontal directions to the
same setting.
Use TRIGGER to set the timing at which the scope measures the signal input.
Explanations of each parameter
Button#/NAME | Pop Up | Enc. Push | Enc. Value |
---|---|---|---|
1: DISPLAY | Overlay | 1 ch mode | 1L, 1R, 2L, 2R |
2 ch mode | 1L-1R, 1L-2L, 1R-2R, 2L-2R | ||
4 ch mode | — | ||
Separate-2 | 2 ch mode | 1L-1R, 1L-2L, 1R-2R, 2L-2R | |
4 ch mode | — | ||
Separate-4 | — | — | |
X-Y | XY | 1L-1R, 1L-2L, 1R-2R, 2L-2R | |
XY-TY overlay | 1L-1R, 1L-2L, 1R-2R, 2L-2R | ||
2: VERTICAL | 1L | Input mode (DCAC) | Vertical range: |
10 mV–10 V/div (10 m, 20 m,
50 m, 0.1, 0.2, 0.5, 1, 2, 5, 10)
1R
2L
2R
3: HORIZONTAL| Sec/Div| —| Horizontal range:
50 us–1 s/div (50, 100, 200,
500, 1 m, 2 m, 5 m, 10 m,
20 m, 50 m, 100 m, 200 m,
500 m, 1)
Position| Set position to zero| Change center position
4: TRIGGER| Auto| Set trigger level to zero| Set trigger level:
−5.00 V–5.00 V (0.01 V step)
Rise
Fall
Rise single
Fall single
START/STOP| —| —| Oscilloscope RUN/STOP
- Buttons 1–4 + value knob (when the popup is shown): edits the popup item.
- Button 4 + value knob: push to edit what is triggered.
- START/STOP button: controls the run/stop and single mode standby.
Function generator mode (WAVE)
Use this mode to output oscillator /noise signals that can be handled as
audio, or to output LFO/PULSE/envelope signals that can be handled as CV
signals. OUTPUT 1 and 2 are completely independent, and different categories
can be selected and used for each.
Button 1 (button 3): explanations of each parameter
Button#/NAME | Pop Up | Enc. Push | Enc. Value |
---|---|---|---|
1 (3): CATEGORY | CATEGORY | — | Oscillator |
LFO
Noise
Pulse
Envelope
VOLUME| Vpp dBu| Set Output Level
CYCLE MODE| —| Cont.
1-Shot
Push
INPUT MONITOR| —| Off
Input 1L
Input 1R
Input 2L
Input 2R
Button 2 (button 4): explanations of each parameter CATEGORY = Oscillator
Button#/NAME | Pop Up | Enc. Push | Enc. Value |
---|
2: EDIT
| WAVE TYPE| —| Sine, Square, Tri, Saw-Rise, Saw-Fall
PITCH| Frequency Note| 0.01–10.00 kHz / C-0 – G9
SHAPE| Set shape to 50%| 0–100%
PHASE| Set phase to 0°| −180 – +180°
CATEGORY = LFO
Button#/NAME | Pop Up | Enc. Push | Enc. Value |
---|---|---|---|
**** 2: EDIT | WAVE TYPE | — | Sine, Square, Tri, Saw-Rise, Saw-Fall |
FREQUENCY | Frequency BPM | 0.01–10.00 kHz / 0.5–600.0 BPM | |
DIRECTION | Set direction to ± | −, ±, + | |
PHASE | Set phase to 0° | −180 – +180° |
CATEGORY = Noise
Button#/NAME | Pop Up | Enc. Push | Enc. Value |
---|---|---|---|
**** 2: EDIT | WAVE TYPE | — | White, Pink |
TIME | Period BPM | 1 ms–10.0 s / 0.5–600.0 BPM | |
— | — | — | |
DUTY | Set duty to 100% | 0–100% |
CATEGORY = Pulse
Button#/NAME | Pop Up | Enc. Push | Enc. Value |
---|---|---|---|
**** 2: EDIT | WAVE TYPE | — | Positive, Negative |
TIME | Period BPM | 1 ms–10.0 s / 0.5–600.0 BPM | |
— | — | — | |
DUTY | Set duty to 50% | 0–100% |
CATEGORY = Envelope
Button#/NAME | Pop Up | Enc. Push | Enc. Value |
---|---|---|---|
**** 2: EDIT | WAVE TYPE | — | Linear, Exp. |
TIME | Period BPM | 1 ms–10.0 s / 0.5–600.0 BPM | |
SHAPE | Set shape to 50% | 0–100% | |
DUTY | Set duty to 100% | 0–100% |
Spectrum analyzer mode (FFT)
Spectrum analyzer mode uses an FFT (fast Fourier transform) function that lets
you monitor the reference waveform along with a frequency spectrogram of the
input signal. This is useful for seeing where the effects of a filter or the
changes you make to a waveform appear in the frequency bands.
Explanations of each parameter
Button#/NAME | Pop Up | Enc. Push | Enc. Value |
---|---|---|---|
1: INPUT | — | Input mode: ACDC | 1L, 1R, 2L, 2R |
2: VERTICAL | INPUT 1L | Input mode: ACDC | VERTICAL RANGE: |
10 mV–10 V/div (10 m,
20 m, 50 m, 0.1, 0.2, 0.5, 1,
2, 5, 10)
INPUT 1R
INPUT 2L
INPUT 2R
3: HORIZONTAL| Sec/Div| —| Time range (50 us–1 s/div)
Position| Set position to zero| Change center position
FFT
Range| —| FFT max Range (1 k–20 kHz)
FFT
Position| —| FFT min Range (0–19 kHz)
4: TRIGGER| AUTO,
Rise, Fall| Set trigger level to zero| Set trigger level:
−5.00 V–5.00 V (0.01 V step)
START/STOP| –| –| FFT RUN/STOP
- Buttons 1–4 + value knob (when the popup is shown): edits the popup item.
- START/STOP button: controls the run/stop and single mode standby.
Tuner mode (TUNER)
Use the tuner to tune one of the four input signals. Both a horizontal meter and a needle-type (VU) meter view are available.
You can set the reference pitch to a value other than 440 Hz (this is also
called “concert pitch,” meaning a range from middle C to the A below that).
With this function, you can tune multiple oscillators at the same time by
transmitting the same pitch (note) and adjusting the pitch while monitoring.
Explanations of each parameter
Button#/NAME | Pop Up | Enc. Push | Enc. Value |
---|---|---|---|
1: DISP | NEEDLE | — | — |
METER
2: INPUT| INPUT 1L| —| —
INPUT 1R| —| —
INPUT 2L| —| —
INPUT 2R| —| —
INPUT 1L INPUT 1R| —| —
INPUT 2L INPUT 2R| —| —
3: CALIB| —| Set CALIB to 440 Hz| A4 CALIB (410–480 Hz)
4: SCOPE| SCOPE VIEW On, Off| —| —
- The vertical range and horizontal range settings for scope view can be configured in scope mode.
Global mode
Used for configuring the overall unit.
1: Input
Parameter | Display | Notes | |
---|---|---|---|
Scope Trigger | INPUT 1L , INPUT 1R, INPUT 2L, INPUT 2R | Configures what |
is triggered in scope mode.
INPUT 1L| Coupling| DC , AC| ** Sets the coupling for the input
signal. When this is set to AC mode, the DC signal is cut.
Filter| Off , On
INPUT 1R| Coupling| DC , AC
Filter| Off , On
INPUT 2L| Coupling| DC , AC| ** Reduces high-frequency noise included
in the input signal.
Filter| Off , On
INPUT 2R| Coupling| DC , AC
Filter| Off , On
2: SETTINGS
Parameter | Display | Notes | |
---|---|---|---|
Display | Brightness | 0, 10, 20, … 80 , | |
90, 100% | Sets the display brightness. |
Off-time (USB)
| 1 min, 5 min,
10 min , 15 min, infinite| Sets how much time elapses before the display
is turned off when the unit is connected to a USB power source.
Off time (Battery)
| 1 min, 5 min,
10 min , 15 min, infinite| Sets how much time elapses before the display
is turned off when the unit is running on battery power.
Popup disp| Off, On| Sets popups (aside from the main popups) to show or
hide.
Scope slow mode| Fixed , Scroll| Selects the display method for scope
mode, when “Sec/Div” is set to a unit of 100 ms or greater.
When this is “Fixed”, the screen is cleared after the signal is displayed up
to the right edge of the screen, and the signal begins displaying again from
the left side.
When this is “Scroll”, the signal is scrolled to the left and displayed once
the display reaches the position set
in “Position”. (To show the signal over the entire screen, move the “Position”
all the way to the right edge.)
3 : SETTINGS
Parameter | Display | Notes |
---|
Power
| Battery Type| Alkaline , Ni-MH| Selects the battery type.
Auto Power Off (USB)
| 5 min, 15 min,
30 min, 1 hour , inifiniite| Sets the amount of time before auto power-off
is enabled, when this unit is connected to a USB power supply.
Auto Power Off (Battery)
| 5 min, 15 min,
30 min, 1 hour , infinite| Sets the amount of time before auto power-off
is enabled, when this unit is operating on batteries.
Text in boldface indicates the factory default setting.
Specifications
Display: | 2.8″ RGB LCD |
---|---|
Input/Output jacks: | INPUT 1, 2 jack (3.5 mm TRS mini phone jack), THRU 1, 2 |
jack
(3.5 mm TRS mini phone jack), OUTPUT 1, 2 jack (3.5 mm TS
mini phone jack), USB port (type C)
Power source:| USB bus power (500 mA max.) or 2 AAA batteries (2 × alkaline
1.5 V or 2 × NiMH 1.2 V)
Current consumption:| 00 mA or less
Dimensions (W × D × H):| 129 × 78 × 39 mm / 5.08″ × 3.07″ × 1.54″
Weight:| 130 g / 4.59 oz
Included items:| USB cable, assembly instructions
Input/output jacks:
INPUT 1, 2 (stereo × 2)| Input impedance: 1MΩ typ.
Maximum input voltage: −10 V to +10 V
THRU 1, 2 (stereo × 2)
OUTPUT 1, 2 (mono × 2)| Output impedance: 47Ω typ.
Maximum output voltage: −5 V to +5 V
Oscilloscope:|
Display modes:| Single, stereo (INPUT 1L-INPUT 1R, INPUT 1L-INPUT 2L,
INPUT 1R-INPUT 2R, INPUT 2L-INPUT 2R), 4 ch
10 mV–10 V/div, switchable between AC/DC modes
50 us–1 s/div
Vertical
Horizontal
Trigger:| auto, rise, fall, single (rise), single (fall)
Function generator:
Waveforms:| Oscillator, LFO, Noise, Pulse, Envelope
Frequencies:| switchable between 0.01 Hz–10 kHz, Hz, NOTE and BPM modes
Output level:| 10 Vpp max, switchable between V/dB modes
FFT:|
Input:| mono (1L, 1R, 2L, 2R)
Frequency range:| 0 Hz–20 kHz
Tuner :|
Display modes:| needle meter (VU), horizontal meter
Inputs:| mono, stereo (INPUT 1L-INPUT 1R, INPUT 2L-INPUT 2R)
Tuning:| 12-note equal temperament
Detection range:| E0 (20.60 Hz)–G8 (6,272 Hz), when inputting sine waves
Reference pitch range:| A4 = 410–480 Hz (1 Hz steps)
Measurement accuracy:| ±0.1 cents
- Specifications and appearance are subject to change without notice for improvement.
4015-2 Yanokuchi, Inagi-City, Tokyo 206-0812 JAPAN
© 2022 KORG INC.
www.korg.com
Published 06/2022
Documents / Resources