CHAUVET OVATIONE2FC Professional Ovation User Guide
- June 9, 2024
- Chauvet
Table of Contents
CHAUVET OVATIONE2FC Professional Ovation
Safety Notes
These Safety Notes include important information about the installation, use, and maintenance of the Ovation E-2FC.
- The luminaire is intended for professional use only.
- The luminaire should be positioned so that prolonged staring into the luminaire at a distance closer than 9.8 ft (3.0 m) is not expected.
- If the external flexible cable or cord of this luminaire is damaged, it shall be replaced by a special cord or cord exclusively available from the manufacturer or its service agent.
- The light source contained in this luminaire shall only be replaced by the manufacturer or its service agent or a similarly qualified person.
CAUTION:
- This product’s housing may be hot when operating. Mount this product in a location with adequate ventilation, at least 20 in (50 cm) from adjacent surfaces.
- When transferring the product from extreme temperature environments, (e.g., a cold truck to a warm humid ballroom) condensation may form on the internal electronics of the product. To avoid causing a failure, allow the product to fully acclimate to the surrounding environment before connecting it to power.
- Flashing lights is known to trigger epileptic seizures. Users must comply with local laws regarding notification of strobe use.
ALWAYS:
- Disconnect from power before cleaning the product or replacing the fuse.
- Replace the fuse with the same type and rating.
- Use a safety cable when mounting this product overhead.
- Connect this product to a grounded and protected circuit.
DO NOT:
- Open this product. It contains no user-serviceable parts.
- Look at the light source when the product is on.
- Leave any flammable material within 50 cm of this product while operating or connected to power.
- Connect this product to a dimmer or rheostat.
- Operate this product if the housing, lenses, or cables appear damaged.
- Operate this product outdoors or in any location where dust, excessive heat, water, or humidity may affect it. (IP20)
- ONLY use the hanging/mounting bracket to carry this product.
- The maximum ambient temperature is 113 °F (45 °C). Do not operate this product at higher temperatures.
- The minimum startup temperature is -4°F (-20°C). Do not start the product at lower temperatures.
- The minimum ambient temperature is -22°F (-30°C). Do not operate the product at lower temperatures.
- To eliminate unnecessary wear and improve its lifespan, during periods of non-use completely disconnect the product from power via a breaker or by unplugging it.
- In the event of a serious operating problem, stop using it immediately.
FCC Compliance
This device complies with Part 15 and Part B of the FCC rules. Operation is subject to the following two conditions:
- This device may not cause harmful interference, and
- This device must accept any interference received, including interference that may cause undesired operation.
Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
RF Exposure Warning for North America and Australia
Warning!
This equipment complies with FCC radiation exposure limits set forth for an
uncontrolled environment. This equipment should be installed and operated with
a minimum distance of 20 cm between the radiator and your body. This
transmitter must not be co-located or operating in conjunction with any other
antenna or transmitter.
What is Included
- Ovation E-2FC
- Seetronic® Powerkon® IP65 power cord
- Ovation metal gobo holder (M size)
- Soft focus filter
- Quick Reference Guide
Control Panel Description
Button | Function |
---|---|
< MENU> | Exits from the current menu or function |
< ENTER> | Enables the currently displayed menu or sets the currently |
selected value into the selected function
< UP>| Navigates upwards through the menu list or increases the numeric
value when in a function
< DOWN>| Navigates downwards through the menu list or decreases the
numeric value when in a function
Scan the QR code to access the product page, warranty terms, and the complete User Manual
Contact Us
Chauvet World Headquarters
General Information
- Address: 3360 Davie Rd. Davie, FL 33314
- Voice: 954-577-4455 Fax: 954-929-5560 Toll-Free: 800-762-1084
- Voice: 844-393-7575
- Fax: 954-756-8015
- Email: chauvetcs@chauvetlighting.com
- Website: www.chauvetprofessional.com.
Chauvet U.K.
- Address: Unit 1C Brookhill Road Industrial Estate Pinxton, Nottingham, UK NG16 6NT
- Voice: +44 (0) 1773 511115 Fax: +44 (0) 1773 511110
- Email: UKtech@chauvetlighting.eu.
- Website: www.chauvetprofessional.eu.
Chauvet Benelux
- Address: Stokstraat 18 9770 Kruishoutem Belgium
- Voice: +32 9 388 93 97
- Email: BNLtech@chauvetlighting.eu
- Website: www.chauvetprofessional.eu.
Chauvet France
- Address: 3, Rue Ampère 91380 Chilly-Mazarin France
- Voice: +33 1 78 85 33 59
- Email: FRtech@chauvetlighting.fr.
- Website: www.chauvetprofessional.eu.
Visit the applicable website above to verify our contact information and instructions to request support. Outside the U.S., U. K., Ireland, Mexico, France, Germany, or Benelux, contact the dealer of record.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>