Peerless RNNAWI Renna LED Tunable Luminaire Instruction Manual
- June 9, 2024
- Peerless
Table of Contents
Peerless RNNAWI Renna LED Tunable Luminaire
IMPORTANT SAFEGUARDS
When using electrical equipment, basic safety precautions should always be followed including the following:
READ AND FOLLOW ALL SAFETY INSTRUCTIONS!
- To reduce the risk of death, personal injury or property damage from fire, electric shock, falling parts, cuts/abrasions, and other hazards please read all warnings and instructions included with and on the fixture box and all fixture labels.
- Before installing, servicing, or performing routine maintenance upon this equipment, follow these general precautions.
- Installation and service of luminaires should be performed by a qualified licensed electrician.
- Maintenance of the luminaires should be performed by person(s) familiar with the luminaires’ construction and operation and any hazards involved. Regular fixture maintenance programs are recommended.
- Do not use outdoors.
- Do not mount near gas or electric heaters.
- Equipment should be mounted in locations and at heights where it will not be subjected to tampering by unauthorized personnel.
- The use of accessory equipment not recommended by the manufacturer may cause an unsafe condition.
- Do not use this equipment for other than its intended use.
- It will occasionally be necessary to clean the outside of the refractor/lens. Frequency of cleaning will depend on ambient dirt level and minimum light output which is acceptable to user. Refractor/lens should be washed in a solution of warm water and any mild, non-abrasive household detergent, rinsed with clean water and wiped dry. Should optical assembly become dirty on the inside, wipe refractor/lens and clean in above manner, replacing damaged gaskets as necessary.
- DO NOT INSTALL DAMAGED PRODUCT! This luminaire has been properly packed so that no parts should have been damaged during transit. Inspect to confirm. Any part damaged or broken during or after assembly should be replaced.
- Recycle: For information on how to recycle LED electronic products, please visit www.epa.gov.
- These instructions do not purport to cover all details or variations in equipment nor to provide every possible contingency to meet in connection with installation, operation, or maintenance. Should further information be desired, or should particular problems arise which are not covered sufficiently for the purchaser’s or owner’s purposes, this matter should be referred to Acuity Brands Lighting, Inc.
WARNING
RISK OF ELECTRIC SHOCK
- Disconnect or turn off power before installation or servicing.
- Verify that supply voltage is correct by comparing it with the equipment label information.
- Make all electrical and grounded connections in accordance with the National Electrical Code (NEC) and any applicable local code requirements.
- All wiring connections should be capped with UL approved recognized wire connectors.
CAUTION RISK OF INJURY
- Wear gloves and safety glasses at all times when removing equipment from carton, installing, servicing or performing maintenance.
- Avoid direct eye exposure to the light source while it is on.
WARNING RISK OF BURN
- Allow lamp/fixture to cool before handling. Do not touch hot lens, lamp, guard, or enclosure.
- Do not exceed maximum wattage marked on luminaire label.
- Follow all lamp manufacturer’s warnings, recommendations and restrictions on lamp operation including but not limited to: ballast type, burning position, replacement, and recycling..
CAUTION RISK OF FIRE
- Keep combustible and other materials that can burn away from lamp/lens.
- Do not operate in close proximity to persons, combustible materials or substances affected by heat or drying.
CAUTION
RISK OF PRODUCT DAMAGE
- Modulus luminaires should only receive low voltage DC power provided from an adequately-rated Modulus head unit. DO NOT CONNECT LINE VOLTAGE TO MODULUS LUMINAIRES.
- Never connect components under load.
- Do not mount or support these fixtures in a manner that can cut the outer jacket or damage wire insulation.
- Unless individual product specifications deem otherwise: Never connect an LED product directly to a dimmer packs, occupancy sensors, timing devices, or other related control devices. LED fixtures must be powered directly off a switched circuit.
- Unless individual product specifications deem otherwise: Do not restrict fixture ventilation. Allow for some volume of airspace around fixture. Avoid covering LED fixtures with insulation, foam, or other material that will prevent convection or conduction cooling.
- Unless individual product specifications deem otherwise: Do not exceed fixtures maximum ambient temperature.
- Only use fixture in its intended location.
- LED products are Polarity Sensitive. Ensure proper Polarity before installation.
- Electrostatic Discharge (ESD): ESD can damage LED fixtures. Personal grounding equipment must be worn during all installation or servicing of the unit.
- Do not touch individual electrical components as this can cause ESD, shorten lamp life, or alter performance.
- Some components inside the fixture may not be serviceable. In the unlikely event your unit may require service, stop using the unit immediately and contact an ABL representative for assistance.
- Always read the fixtures complete installation instructions prior to installation for any additional fixture specific warnings.
Please see product specific installation instructions for additional warnings
or any applicable FCC or other regulatory statements.
Failure to follow any of these instructions could void product warranties. For
a complete listing of product Terms and Conditions, please visit
www.acuitybrands.com.
Acuity Brands Lighting, Inc. assumes no responsibility for claims arising out
of improper or careless installation or handling of its products.
ABL LED General Warnings, Form No. 503.203
© 2010 Acuity Brands Lighting, Inc. All rights reserved. 12/01/10
WARNING: Pleaseread the“important safetyinstructions” priorto installation of thisproduct. The mounting instructions can be found inside themounting kits or downloaded from https://peerlesslighting.acuitybrands.com/Renna
Identification of Renna Luminaire
IMPORTANT: Wearcotton gloves AND lift and handle theluminaire from theends to avoid damaging or soiling thelens surface. Should the lens surface become smudged or otherwise blemished, clean using only a soft, microfiber/cotton cloth.
- A.1 Types of Luminaire:
- A.2 Typical Luminaire layout:
IMPORTANT: Each luminaire section must be paired with its corresponding driver enclosure. Look for matching numbers on theluminaire and head unit packaging boxes.
Overview of RNNAW Installation
- B.1 Overview of Installation for Grid Ceiling (F1)
- B.2 Overview of Installation for Surface Ceiling (F2)
- B.3 RNNAW Typical Run
- B.4 RNNAW Feed and Support Kit
Luminaire Installation for Wall mount (F2)
-
Laser level to mark a line for hole locations in bracket.
-
The Renna run should start on a stud. Mark the point where the center of the first stud crosses the level line from step 1. If the run must start between studs, add structural blocking behind the wall to anchor the wall bracket.
-
Align the first hole on the wall bracket with the mark from Step 2. Then determine the location where the Mini J-box should be installed. Mounting holes on the j-box should align with holes on the wall bracket that fall between the same studs where the feed circuit was installed. Once you’ve picked a location for the j-box, mark the center of the wall bracket holes it will mount to on your level line from Step 1.
-
Remove the Wall Bracket and place the Mini J-box opening against the wall, aligning its mounting holes with the points marked in step 3. Use a pencil to trace a cut line around the j-box onto the wall.
-
Cut drywall to the inside of the traced cut line, being careful not to cut into the feed circuit hanging inside the wall.
-
Pull the conduit containing the feed circuit through the hole in the drywall. Punch out the knock-out in the Mini J-box, feed conductors through the hole, and connect the conduit with a 1/2″ trade-size conduit connector (by others).
-
Punch out a knock-out in the wall bracket aligning with the Mini J-box and install the included strain-relief in the hole.
-
Feed bare ends of cord through the strain relief, make connections with wires coming through conduit.
-
Attach Mini J-Box to the back of the bracket with included #8-32 screw and nut hardware.
-
Prepare sub-assembly of wall bracket end cap , wall bracket and 2X cantilever arms using 3X #6-32 screws (from the kit) partially tightened as shown.
For U8 luminaires, use 2X 4ft wall brackets butted end-to-end, joined with a third cantilever arm. -
Feed the excess conduit and j-box into the hole in the wall. Press the wall bracket against the wall and drive a #8 (minimum) screw appropriate for the studs through the first hole into the stud on the mark from step 1. Drive a second screw through the last hole on the right end of the bracket that aligns with a stud [the diagram in Step 2 shows the hole alignment for 16″ stud pitch].
-
Route the cord to the left end of the wall bracket where the fixture run will begin and hang the connector over the end of the cantilever arm. Loop the excess cord down the length of the wall bracket, letting the tension in the bend in the cord hold it between the flanges of the wall bracket.
-
Pivot and hook the luminaire using 2X flanges on both ends and place it onto the wall brackets as shown. Slide and adjust the cantilever arm on both sides (within the bracket slot) to ensure that the knuckle screw from luminaire is aligned to center of cantilever arm slot properly for fastening.
-
Once the luminaire is adjusted, tighten the luminaire to the cantilever arm on both sides using 2X locknuts (provided in kit). Tighten the 3X screws mounted in step C10. TORQUE: 8.2-9.2 in. lbs.
-
After the luminaire is assembled, loosen the set screw from the luminaire knuckle. Slide the end cap towards the luminaire and fasten it to the luminaire using the set screw. TORQUE: 4.2-5.8 in. lbs
-
Remove the washer head screw on top of fixture bracket. Once end cap is assembled, locate the left cantilever cover above the end cap. Fasten it to the luminaire using the washer head screw and a #6 screw (provided in the kit). TORQUE: 8.2-9.2 in.lbs
-
Align the end cover with the wall bracket and mount it to the wall. Fasten it to the cantilever using 1X screw (provided in the kit). Assemble the end cap and right cantilever cover similar to steps C15-C16 on the other side of the luminaire.
-
FOR THE RUN:
Assemble the first luminaire and the wall bracket in the run according to steps C1-C16. -
Prepare sub-assembly of wall bracket and 1X cantilever assembly using 1X screw (from the kit) as shown. Assemble to the previous wall bracket using 1X #6-32screw (fully tighten) and mount it to the wall.
-
Align the next luminaire in the run to the previous luminaire. Pivot and hook the luminaire using 2X flanges on both ends and place it onto the wall brackets as shown.
-
Slide and adjust the cantilever arm on right side of intermediate luminaire (within the bracket slot) to ensure that the knuckle screw from luminaire is aligned to center of cantilever arm slot properly for fastening. Tighten the partial mounted screw from step C19 and 1X locknut (from kit) on right side of intermediate luminaire.
TORQUE: 8.2-9.2 in.lbs -
Loosen the set screw of the knuckle on right side of the luminaire. Assemble the intermediate luminaire to the previous luminaire by tightening the set screw. TORQUE: 4.2-5.8 in.lbs
Complete the harness between both luminaires using F-M cable (from the kit). -
For section to section joining only:
The luminaire run can be adjusted straight even when the wall is not perfectly flat. This can be done by tightening the set screws of the knuckle first, followed by completely tightening the locknut. -
23b For U8 mid-span only:
Attach cantilever arm at mid-point of U8 fixtures to the internal extrusion in the fixture using #6-32 screw.
TORQUE: 6.0-7.0 in.lbs -
Install the reflector (provided in the kit) using 2X #6-32 screws (from the kit) to the luminaire housing as shown. Ensure that the wire harness is properly located below the kicker to avoid pinching.
TORQUE: 6.0-7.0 in.lbs -
Remove 2X washer head screws from the top of luminaire. Assemble the mid-span joiner cover (from the kit) above the cantilever assembly and fasten it using same washer head screws. Repeat steps C19-C25 on all intermediate luminaires.
TORQUE: 8.2-9.2 in.lbs -
Align the right end cover with the wall bracket and mount it to the wall. Fasten it to the cantilever using 1X #6-32 screw (provided in the kit). Assemble the end cap and right cantilever cover similar to steps C15-C16 on the other side of the luminaire.
© 2014 Acuity Brands Lighting, Inc. All Rights Reserved.. Products in this document may be covered by one or more U.S. Patents and Patents Pending. Specifications subject to change without notice. Limited warranty applies. Complete warranty terms located at www.AcuityBrands.com/CustomerResources/Terms_and_Conditions.aspx
References
- Acuity Brands | Lighting, Controls, and Building Management Solutions
- Acuity Brands | Lighting, Controls, and Building Management Solutions
- U.S. Environmental Protection Agency | US EPA
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>