PENTAIR 011075 IntelliFlo3 VSF Pool Pump User Guide
- June 9, 2024
- Pentair
Table of Contents
011075 IntelliFlo3 VSF Pool Pump
User Guide
011075 IntelliFlo3 VSF Pool Pump
PENTAIR HOME
FOR INTELLIFLO3™ VSF AND INTELLIPRO3™ VSF VARIABLE SPEED AND FLOW PUMPS
IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS
SAVE THESE INSTRUCTIONS
Digital copies of all IntelliFlo3 VSF manuals, as well as translated versions,
can be found at www.pentair.com, or by scanning the
provided QR code.
- Install and Maintenance Guide (P/N 356231)
- User’s Guide (P/N 356088)
https://www.pentair.com/intelliflo3-manuals
IMPORTANT SAFETY INSTRUCTIONS
IMPORTANT NOTICE
This guide provides installation and operation instructions for this pump.
Consult Pentair with any questions regarding this equipment.
Attention Installer: This guide contains important information about the
installation, operation and safe use of this product. This information should
be given to the owner and/or operator of this equipment after installation or
left on or near the pump.
Attention User: This manual contains important information that will help you
in operating and maintaining this product. Please retain it for future
reference.
READ AND FOLLOW ALL INSTRUCTIONS
SAVE THESE INSTRUCTIONS
This is the safety alert symbol. When you see this symbol on your system or in
this manual, look for one of the following signal words and be alert to the
potential for personal injury.
Warns about hazards that can cause death, seriouspersonal injury, or major
property damage if ignored.
Warns about hazards that may cause death, serious personal injury, or major
property damage if ignored.
Warns about hazards that may or can cause minor personal injury or property
damage if ignored.
NOTE Indicates special instructions not related to hazards.
Carefully read and follow all safety instructions in this manual and on
equipment. Keep safety labels in good condition; replace if missing or
damaged.
When installing and using this electrical equipment, basic safety precautions
should always be followed, include the following:
FAILURE TO FOLLOW ALL INSTRUCTIONS AND WARNINGS CAN RESULT IN SERIOUS BODILY
INJURY OR DEATH. THIS PUMP SHOULD BE INSTALLED AND SERVICED ONLY BY A
QUALIFIED POOL SERVICE PROFESSIONAL. INSTALLERS, POOL OPERATORS AND OWNERS
MUST READ THESE WARNINGS AND ALL INSTRUCTIONS IN THE OWNER’S MANUAL BEFORE
USING THIS PUMP. THESE WARNINGS AND THE OWNER’S MANUAL MUST BE LEFT WITH THE
POOL OWNER.
Do not permit children to use this product.
RISK OF ELECTRICAL SHOCK. Connect only to a branch circuit protected by a
ground-fault circuit- interrupter (GFCI). Contact a qualified electrician if
you cannot verify that the circuit is protected by a GFCI.
This unit must be connected only to a supply circuit that is protected by a
ground-fault circuit-interrupter (GFCI). Such a GFCI should be provided by the
installer and should be tested on a routine basis. To test the GFCI, push the
test button. The GFCI should interrupt power. Push the reset button. Power
should be restored. If the GFCI fails to operate in this manner, the GFCI is
defective. If the GFCI interrupts power to the pump without the test button
being pushed, a ground current is flowing, indicating the possibility of an
electric shock. Do not use this pump. Disconnect the pump and have the problem
corrected by a qualified service representative before using.
This pump is for use with permanent swimming pools and may also be used with
hot tubs and spas if so marked. Do not use with storable pools. A permanently-
installed pool is constructed in or on the ground or in a building such that
it cannot be readily disassembled for storage. A storable pool is constructed
so that it is capable of being readily disassembled for storage and
reassembled to its original integrity.
General Warnings
- Never open the inside of the drive motor enclosure. There is a capacitor bank that holds a 230 VAC charge even when there is no power to the unit.
- The pump is not submersible.
- The pump is capable of high flow rates; use caution when installing and programming to limit pumps performance potential with old or questionable equipment.
- Code requirements for electrical connection differ from country to country, state to state, as well as local municipalities. Install equipment in accordance with the National Electrical Code and all applicable local codes and ordinances.
- Before servicing the pump; switch OFF power to the pump by disconnecting the main circuit to the pump.
- This appliance is not intended for use by persons (including children) of
reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning the use of the appliance by a person responsible for their safety.
SUCTION ENTRAPMENT HAZARD: STAY OFF THE MAIN DRAIN AND AWAY FROM ALL SUCTION OUTLETS! THIS PUMP IS NOT EQUIPPED WITH SAFETY VACUUM RELEASE SYSTEM (SVRS) PROTECTION AND DOES NOT PROTECT AGAINST BODY OR LIMB ENTRAPMENTS, DISEMBOWELMENTS (WHEN A PERSON SITS ON A BROKEN OR UNCOVERED POOL DRAIN) OR HAIR ENTANGLEMENTS.
THIS PUMP PRODUCES HIGH LEVELS OF SUCTION AND CREATES A STRONG VACUUM AT THE
MAIN DRAIN AT THE BOTTOM OF THE BODY OF WATER. THIS SUCTION IS SO STRONG THAT
IT CAN TRAP ADULTS OR CHILDREN UNDER WATER IF THEY COME IN CLOSE PROXIMITY TO
A DRAIN OR A LOOSE OR BROKEN DRAIN COVER OR GRATE.
THE USE OF UNAPPROVED COVERS OR ALLOWING USE OF THE POOL OR SPA WHEN COVERS
ARE MISSING, CRACKED OR BROKEN CAN RESULT IN BODY OR LIMB ENTRAPMENT, HAIR
ENTANGLEMENT, BODY ENTRAPMENT, EVISCERATION AND/OR DEATH.
The suction at a drain or outlet can cause:
Limb Entrapment: When a limb is sucked or inserted into an opening resulting
in a mechanical bind or swelling. This hazard is present when a drain cover is
missing, broken, loose, cracked or not properly secured.
Hair Entanglement: When the hair tangles or knots in the drain cover, trapping
the swimmer underwater. This hazard is present when the flow rating of the
cover is too small for the pump or pumps.
Body Entrapment: When a portion of the body is held against the drain cover
trapping the swimmer underwater. This hazard is present when the drain cover
is missing, broken or the cover flow rating is not high enough for the pump
or pumps.
Evisceration/Disembowelment: When a person sits on an open pool (particularly
a child wading pool) or spa outlet and suction is applied directly to the
intestines, causing severe intestinal damage. This hazard is present when the
drain cover is missing, loose, cracked, or not properly secured. Mechanical
Entrapment: When jewelry, swimsuit, hair decorations, finger, toe or knuckle
is caught in an opening of an outlet or drain cover. This hazard is present
when the drain cover is missing, broken, loose, cracked, or not properly
secured.
NOTE: ALL SUCTION PLUMBING MUST BE INSTALLED IN ACCORDANCE WITH THE
LATEST NATIONAL AND LOCAL CODES, STANDARDS AND
GUIDELINES.
TO MINIMIZE THE RISK OF INJURY DUE TO SUCTION ENTRAPMENT HAZARD:
- A properly installed and secured ANSI/ASME A112.19.8 approved antientrapment suction cover must be used for each drain.
- Each suction cover must be installed at least three (3’) feet apart, as measured from the nearest point to nearest point.
- Regularly inspect all covers for cracks, damage and advanced weathering.
- If a cover becomes loose, cracked, damaged, broken or is missing, replace with an appropriate certified cover.
- Replace drain covers as necessary. Drain covers deteriorate over time due to exposure to sunlight and weather.
- Avoid getting hair, limbs or body in close proximity to any suction cover, pool drain or outlet.
- Disable suction outlets or reconfigure into return inlets.
The pump can produce high levels of suction within the suction side of the
plumbing system. These high levels of suction can pose a risk if a person
comes within the close proximity of the suction openings. A person can be
seriously injured by this high level of vacuum or may become trapped and
drown. It is absolutely critical that the suction plumbing be installed in
accordance with the latest national and local codes for swimming pools.
A clearly labeled emergency shut-off switch for the pumpmust be in an easily
accessible, obvious place. Make sure users know where it is and how to use it
in case of emergency.
The Virginia Graeme Baker (VGB) Pool and Spa Safety Act creates new
requirements for owners and operators of commercial swimming pools and spas.
Commercial pools or spas constructed on or after December 19, 2008, shall
utilize:
(A) A multiple main drain system without isolation capability with suction
outlet covers that meet ASME/ANSI A112.19.8a Suction Fittings for Use in
Swimming Pools, Wading Pools, Spas, and Hot Tubs and either:
(i) A safety vacuum release system (SVRS) meeting ASME/ANSI A112.19.17
Manufactured Safety Vacuum Release systems (SVRS) for Residential and
Commercial Swimming Pool, Spa, Hot Tub, and Wading Pool Suction Systems and/or
ASTM F2387 Standard Specification for Manufactured Safety Vacuum Release
Systems (SVRS) for Swimming pools, Spas and Hot Tubs or
(ii) A properly designed and tested suction-limiting vent system or
(iii) An automatic pump shut-off system.
Commercial pools and spas constructed prior to December 19, 2008, with a
single submerged suction outlet shall use a suction outlet cover that meets
ASME/ANSI A112.19.8a and either:
(A) A SVRS meeting ASME/ANSI A112.19.17 and/or ASTM F2387, or
(B) A properly designed and tested suction-limiting vent system, or
(C) An automatic pump shut-off system, or
(D) Disabled submerged outlets, or
(E) Suction outlets shall be reconfigured into return inlets.
For Installation of Electrical Controls at Equipment Pad (ON/OFF Switches,
Timers and Automation Load Center)
Install all electrical controls at equipment pad, such as on/off switches,
timers, and control systems, etc. to allow the operation (startup, shut-down,
or servicing) of any pump or filter so the user does not place any portion of
his/her body over or near the pump strainer lid, filter lid or valve closures.
This installation should allow the user enough space to stand clear of the
filter and pump during system start-up, shut down or servicing of the system
filter.
HAZARDOUS PRESSURE: STAND CLEAR OF PUMP AND FILTER DURING START UP.
Circulation systems operate under high pressure. When any part of the
circulating system (i.e. locking ring, pump, filter, valves, etc.) is
serviced, air can enter the system and become pressurized. Pressurized air can
cause the pump housing cover, filter lid, and valves to violently separate
which can result in severe personal injury or death. Filter tank lid and
strainer cover must be properly secured to prevent violent separation. Stand
clear of all circulation system equipment when turning on or starting up pump.
Before servicing equipment, make note of the filter pressure. Be sure that all
controls are set to ensure the system cannot inadvertently start during
service. Turn off all power to the pump. IMPORTANT: Place filter manual air
relief valve in the open position and wait for all pressure in the system to
be relieved.
Before starting the system, fully open the manual air relief valve and place
all system valves in the “open” position to allow water to flow freely from
the tank and back to the tank. Stand clear of all equipment and start the
pump.
IMPORTANT: Do not close filter manual air relief valve until all pressure
has been discharged from the valve and a steady stream of water appears.
Observe filter pressure gauge and be sure it is not higher than the pre-
service condition.
General Installation Information
- All work must be performed by a qualified service professional, and must conform to all national, state, and local codes.
- Install to provide drainage of compartment for electrical components.
- These instructions contain information for a variety of pump models and therefore some instructions may not apply to a specific model. All models are intended for use in swimming pool applications. The pump will function correctly only if it is properly sized to the specific application and properly installed.
Pumps improperly sized or installed or used in applications other than for which the pump was intended can result in severe personal injury or death. These risks may include but not be limited to electric shock, fire, flooding, suction entrapment or severe injury or property damage caused by a structural failure of the pump or other system component.
Pumps and replacement motors that are single speed and one (1) Total HP or greater cannot be sold, offered for sale, or installed in a residential pool for filtration use in California, Title 20 CCR sections 1601-1609.
CUSTOMER SERVICE AND TECHNICAL SUPPORT
Hours: 8:00AM to 7:30PM EST (5:00AM – 4:30PM PST)
Call: 800-831-7133
Visit: www.pentair.com
Fax: 800-284-4151
INTRODUCTION
The Pentair Home app is the perfect solution for remotely monitoring and
controlling your pool equipment from anywhere.
This guide provides instructions on creating an account and using Pentair Home
to get the most out your Pentair Home account and your connected pool
products.
Home Dashboard
From the Home Dashboard you can remotely monitor and control your pool and
equipment. Press a specific equipment tab to display controls. From any other
screen, press the Dashboard Icon [7] to return to the Home Dashboard.
After a compatible device has been added to your Pentair Home account, the
Home Dashboard can be accessed by tapping the corresponding device tab. For an
overview of the Pump Dashboard, refer to Pump Dashboard, page 4.
- Dashboard Settings: Press to access pool info, notification settings and equipment warranty information, or log out of Pentair Home. The Home Dashboard can be customized by pressing EDIT DASHBOARD.
- Contact Pentair: Press to open the Contact Pentair screen. Send a message to Pentair general or device support, or report bugs within the app.
- System Status/Alerts: Displays current system alerts. Press to open a list of alerts.
- Add a Device: Press to open the Add a Device screen. Choose a device to add to your Pentair Home Account. For example; ChemCheck, IntelliConnect, IntelliSync, etc.
- Control System Tab: Displays current system/ device operation mode. PRESS THIS TAB TO ADD EQUIPMENT TO A DEVICE.
- Equipment Tabs: Displays individual equipment status (pump, heater, salt chlorinator, etc.). Press a specific tab to open its Equipment Settings screen.
- Dashboard Icon: Press to return to Home Dashboard from any screen.
- Devices Icon: Press to open the Devices screen. View all connected devices and equipment. Press an equipment tab to open its Settings screen.
- Schedule Icon: Press to open the Schedules calendar. Displays active schedules for connected equipment.
- Notifications Icon: Press to open the Alerts screen. Displays past and present system alerts.
INITIAL SETUP
Creating a Pentair Home Account
Creating a Pentair Home Account
-
From your chosen smart device, download Pentair Home from the Google Play ® store (Android ® devices) or Apple ® app store (iOS ® devices).
Note: Apple operating systems must be iOS ® 11 or later. Android operating systems must be version 6.0 or later. -
Open the Pentair Home app ( ) from your smart device.
-
A series of informational screens will display.
Scroll through these screens to continue. -
The Email Entry screen will display.
Enter your email address and press GET STARTED. -
The Password Creation screen will display. See FIGURE 1.
-
Enter your desired password in both entry fields (1).
-
Review the terms of service by pressing
TERMS OF SERVICE.
Check the Terms of Service Box (2) to acknowledge you have read the Terms of Service. -
Press CREATE MY ACCOUNT (3).
-
The Verify Your Email screen will display and a verification email will be sent to the provided email address.
-
Verify your account using the link in the verification email.
Note: If you do not receive a verification email press I DIDN’T GET THE
EMAIL at the Check Your Email screen and follow on-screen instructions. -
After verification, the Create Profile screen will display. See FIGURE 2.
-
Enter your profile information.
-
Press the STANDARD or METRIC tab to choose which units the app will display.
-
Press SAVE to save entries.
-
Continue to Pairing Devices to your Account, page 3.
|
---|---
https://play.google.com/store/apps/details?id=com.pentair.pentairhome|
https://apps.apple.com/us/app/pentair-home/id1448665466
Pairing Devices to your Account
Several smartphone functions will be used to successfully pair your pump to
your Pentair Home account.
Before signing into the app ensure:
- Your smartphone’s Bluetooth ® wireless technology is turned on
- Your smartphone’s location service is on
- Pentair Home has Bluetooth permissions
TO PAIR A PUMP TO YOUR ACCOUNT:
-
Sign into your Pentair Home account.
-
The Home Dashboard screen will display (FIGURE 3).
Press ADD A DEVICE [1]. -
The Add a Device screen will display (FIGURE 4).
Select your pump from the list of devices.
-
The Installation screen will display. Press CONTINUE.
-
At the pump, press the CONNECT button on the drive.
-
The pump will enter Bluetooth Pairing Mode and the Connect LED will begin pulsing Blue.
-
Select your pump to begin Bluetooth pairing.
-
Wait for the Connect LED to turn solid Blue, then press CONTINUE.
-
Once a Bluetooth connection has been established and confirmed, press CONTINUE.
• If pairing your pump to a WiFi network: Continue to step 10.
• If not pairing your pump to a WiFi network: Press SKIP FOR NOWto connect only via Bluetooth. Refer to Direct Connect, page 7 for additional information.
Note: If the pump is not paired to a WiFi network then Pentair Home control can only be accessed when within Bluetooth rangeof the pump.
It is recommended that the pump be paired to a WiFi network even when not using Pentair Home control. This allows you to receive the latest updates and features. -
The Connect Your Device to WiFi screen will display (FIGURE 5).
Select your WiFi network and enter the password. Press CONTINUE. -
The Device Address screen will display.
Select your address from the Device Address drop down menu and press CONTINUE. -
The Nickname screen will display.
Enter the name you would like your pump to go by within Pentair Home. Press SAVE. -
Installation Completed will display. Press CONTINUE.
-
Your pump is now paired to Pentair Home and ready to use.
OPERATION
Pump Dashboard
The Pump Dashboard is your pump’s home page. Basic pump info, run status and
programming can be viewed from this screen.
If any pump alerts and problems are present they will also display at the top
of this screen.
-
Device Settings: Tap to display the Device Settings screen.
Most of the pump features and settings can be accessed from the Device Settings screen. Refer to Device Settings, page 6. -
Enabled/Disabled Toggle: Tap to enable or disable your pump.
A DISABLED pump will not start until this toggle is switched to ENABLED or the pump ON/STOP button is pressed. -
Current Status: Displays the current pump state.
IDLE: The pump is not currently running a program. PROGRAM: Displays the program currently running. -
Next Program: Displays the next program scheduled to run after completion of the current program or idle.
If all programs are programmed manual or timer
“No Programs are Scheduled” will display. -
Run Data: Displays estimates of the pump’s current flow, power consumption and overall system pressure.
-
Program Tabs: Displays all pump Programs and their individual settings.
Tap a Program Tab to edit or start a program.
Refer to Program Setup, page 5 for programming instructions.
Note: Quick Clean will always display as a program tab and cannot be removed from the Pump Dashboard. Quick Clean is programmed similarly to a Timer program. -
Edit/Run Program Tabs: Displays when a Program Tab is pressed.
EDIT: Tap to open the Program Setup screen.
Refer to Program Setup, page 5.
RUN NOW/STOP: Tap to manually start or stop a pump program.
Program Setup
The pump allows you to create and customize up to 8 unique programs.
The pump also features a default Quick Clean program that can be customized,
but not renamed or deleted.
-
Schedule Enabled/Disabled Toggle: Tap to enable or disable a Schedule Program.
If disabled, the schedule program is inactive and will not run until it is re- enabled.
This toggle will only appear if a program is Schedule Mode. -
Program Nickname: Displays the name a specific program will display on the Pump Dashboard.
Tap the entry field to edit the program name. -
Program Mode: Displays the current Program Mode.
Tap a mode tab to select a mode.
• MANUAL: A manual program must be manually started and stopped from the Pump Dashboard. The program will not repeat and will run until it is manually stopped.
• TIMER: A timer program must be manually started from the Pump Dashboard but will automatically stop at the end of its set duration. The program will not repeat and will only run for its set duration.
• SCHEDULE: A schedule program will automatically start and stop based on its day, start time and end time settings. The program will repeat at the same time each day on each day selected. -
Set Schedule/Timer:
• MANUAL MODE: This option will not display for manual mode programs.
• TIMER MODE: Set the run duration for timer mode programs.
• SCHEDULE MODE: Select which days of the week you want the pump to run and set the duration of these daily runs. -
Pump Speed/Flow: Displays the Speed (percentage of maximum speed) or the Flow (GPM) set for the program.
Tap the Speed or Flow tab to determine which of these measurements is displayed.
Use either the +/- buttons to edit the speed/flow setting in minor increments or the slider to edit in larger increments.
The Activated/Deactivated toggle shows the state of the pump.
If ACTIVATED, the pump is currently active and able to run a program. -
Relay Toggles: Tap a relay toggle to determine whether a wired device is active during the program run time.
If a device relay is Activated, the device will run along with pump the entirety of manual, timer or schedule program.
These toggles only display if the Relay Control Board (P/N 356365z — sold separately) has been installed. -
Save: Tap to save edits made to program settings.
The SAVE button must be pressed in order to save edits to settings; otherwise they will be lost. -
Remove Program: Tap to permanently delete a program from the Pump Dashboard.
Device Settings
Device Settings can be accessed by pressing the Device Settings gear icon ( )
in the top-right of the Device Dashboard.
-
Product Overview: View and edit general information about your
IntelliFlo3 VSF such as device nickname or address. -
Notifications: Control where and how device notifications are delivered.
-
Product Support: Opens the IntelliFlo Support page.
-
Remote Monitoring: Use your address to find and contact local pool professionals offering to monitor your pump remotely. Search results will only contain professionals offering remote monitoring.
Remote monitoring permissions can be given and revoked from this screen at any point. -
Contact a Professional: Use your address to find a local pool professional.
Search results will contain available local pool professionals. -
WiFi: View and update the WiFi network you are currently paired to, as well as signal strength.
-
Relays: View and edit your current pump relay device settings and nicknames.
This functionality is only available if the Relay Control Board (P/N 356365z — sold separately) has been installed.
Refer to Relays, page 7. -
Alerts History: Displays a list of device alerts.
-
Direct Connect: Setup the Direct Connect feature.
This feature allows you to control your pump without an internet connection.
Refer to Direct Connect, page 7. -
Priming Parameters: View and edit your pump’s priming settings.
Refer to Priming Parameters, page 8. -
Limits Parameters: View and edit your pump’s speed, flow and pressure limits.
Refer to Limits Parameters, page 8. -
Thermal Mode: View and edit the your pump’s Thermal Mode temperature set point and speed/flow settings.
Refer to Thermal Mode, page 9. -
Automation Address: View and edit the pump address associated with your automation system.
The pump address entered on this screen must match the address in the automation system. If addresses do not match, the pump can not communicate with an automation system. -
External Control Programs: View and edit the four programs that can be triggered by an external input signal when using the optional Relay Control Board (P/N 356365z).
-
Ramping Speed: Determine how quickly your pump will ramp up or down on startup or when changing speeds/flows.
Ramping Speed can be set to FAST, MEDIUM or SLOW. -
Device Security: Set a 4-digit PIN controlling access to pump controls.
-
Device Resets: Restore system defaults for all programs and device settings.
-
Remove Device: Remove the pump and pump relay devices from your Pentair Home account.
Relays
Pump Dashboard ˃ Device Settings ˃ Relays
The following functionality is only available if the Relay Control Board (P/N
356365z — sold separately) has been installed.
The relay board includes two high-voltage terminals capable of controlling
pool lights, salt chlorine generators or other filtration system components.
One terminal is intended for 5A max lowcurrent connections and the other for
16Amax high-current connections.
-
Device Type: Select the device connected to a particular relay.
• RELAY 1 Options: Lights, Salt Cell or Other
• RELAY 2 Options: Lights, Salt Cell, Booster Pump or Other
Note: If a relay is designated “Booster Pump”, the pump will first ensure the Booster Pump has water by delaying power to the relay until the pump has run for two minutes.
If the pump is already running a program then there will be no delay. -
Device Nickname: Enter the name you want your device to display on Program Setup screens.
-
Speed/Flow Dependent: Check this box to ensure the relay is only activated when the pump is running.
-
Add/Remove: Tap to add or remove a relay.
Direct Connect
Pump Dashboard ˃ Device Settings ˃ Advanced Settings > Direct Connect
Direct Connect mode allows you to program and operate your pump without a WiFi
connection, via a Bluetooth ® wireless technology connection.
TO PLACE THE PUMP INTO DIRECT CONNECT MODE:
- Ensure your smartphone is within Bluetooth range of the pump, Bluetooth is enabled on your smartphone and Pentair Home has Bluetooth permissions.
- At the pump, press the CONNECT button to enter pairing mode. The pump’s CONNECT LED will blink blue.
- Open Device Settings and select Direct Connect.
- Press CONTINUE at the Bluetooth Pairing screen.
- Once a Bluetooth connection is established, the pump’s CONNECT LED will turn solid blue.
When connected to the pump via Bluetooth, the following options will appear in the Direct Connect menu:
SET-UP WIFI: Tap to establish a WiFi internet connection between your phone and the pump. WiFi will now be your primary connection.
DISCONNECT: Tap to disconnect your Bluetooth wireless connection.
Note: When the pump is programmed to operate in Direct Connect mode and has been powered off, the Connect
LED will pulse yellow. This indicates that the pump needs to be re-paired with your smartphone.
Press the CONNECT button to reconnect with your previously paired smartphone.
Note: When connected via WiFi, a green dot will display beside the pump nickname on the Pump Dashboard.
When connected via Bluetooth and operating in Direct Connect mode, the Bluetooth symbol will display beside the pump nickname on the Pump Dashboard.
Priming Parameters
Pump Dashboard ˃ Device Settings ˃ Advanced Settings > Priming Parameters
All priming settings can be edited and set from this screen. Tap a specific
setting on the right-side of the screen to edit.
-
Enabled/Disabled: ENABLED allows the pump to detect whether or not the system is properly primed for pump startup. If prime is not detected the pump will enter a priming cycle, based on the settings below.
-
Priming Speed: Set the speed the pump will run during a priming cycle.
-
Max Priming Duration: Set the maximum amount of time the pump will attempt to prime.
If the pump does not achieve prime during this time a priming errorwill display and the pump will stop. -
Priming Range: Set the sensitivity of pump prime detection. Lower settings require higher flow to detect a successful prime.
-
Priming Delay: Set the amount of time the pump remains at priming speed before transitioning to the run program.
-
Loss of Prime: ENABLED allows the pump to detect low-flow or no-flow situations while running.
If a loss of prime is detected the pump will pause and attempt to prime, based on the settings above. If priming is successful the pump will continue programmed operation.
Limits Parameters
Pump Dashboard ˃ Device Settings ˃ Advanced Settings > Limits Parameters Set
and edit pump speed, flow and pressure limits. These settings will ensure your
pump does not operate outside of the programmed parameters.
-
Minimum/Maximum Speed: Set the absolute minimum and maximumspeeds the pump will be allowed to run. Pump run speed will never run under or over these two settings.
-
Minimum/Maximum Flow: Set the absolute minimum and maximum flow rate the pump will be allowed. Pump GPM will never fall under or exceed these two settings.
Note: These minimum and maximum flow rates only apply to Flow Programs. To apply these settings to Speed Programs as well, the next setting (Flow Limit – Speed Programs) must be enabled. -
Flow Limit (Speed Programs): Enable or disable minimum and maximum flow rate limits for Speed Programs.
-
Max Pressure: Set the absolute maximum system pressure the pump will be allowed to produce. Pump system pressure will never exceed this setting.
Note: The maximum pressure setting only applies to Flow Programs. To apply these settings to Speed Programs as well, the next setting (Pressure Limit – Speed Programs) must be enabled. -
Pressure Limit (Speed Programs): Enable or disable maximum system pressure limit for Speed Programs.
Thermal Mode
Pump Dashboard ˃ Device Settings ˃ Advanced Settings > Thermal Mode
Thermal Mode is intended to help protect the pump during freezingor near-
freezing conditions.
Note: Do not depend on this feature for freeze protection of the entire
filtration system and pool.
Certain situations could cause the pump to sense a different temperature than
actual air temperature. Your automation system air temperature sensor should
be used to sense actual temperature. For example, if the pump is located
indoors, the temperature of the room does not indicate the outdoor
temperature.
Note: The pump does NOT sense water temperature.
-
Enable/Disable: Enable or disable Thermal Mode protection.
-
Temperature Set Point: Set the temperature at which the
Thermal Mode program will initiate. -
Speed/Flow Display: Determines whether the Speed/Flow setting below is displayed as a percentage of max speed or in GPM.
-
Speed/Flow Setting: Set the Speed% or GPM the pump will run when Thermal Mode is triggered.
-
Save: Saves edits to Thermal Mode settings.
TROUBLESHOOTING
Troubleshooting Chart
PROBLEM | POSSIBLE CAUSE | CORRECTIVE ACTION |
---|---|---|
Connection Issue – Pump is Offline Alert | Pump is not receiving power | Ensure |
the pump is receiving power.
If the pump is receiving power, the ON/STOP button will illuminate.
Home internet service is out or inaccessible| Confirm that the home router is
active and connected to the internet.
Intermittent WiFi or network connection| 1.Restart the home router. This can
clear up many typical home networking issues.
2.Cycle power the pump.
Disconnect power to the pump at the main breaker, Wait for 1 minute and
reconnect power.
3.Check the signal strength in WiFi Settings of the Pentair Home App.
If the signal strength is insufficient, refer to the Poor WiFi Signal section
of this troubleshooting chart.
Bluetooth® connectivity issues| 1.Stand closer to the pump when operating via
Bluetooth.
2.Restart the Pentair Home app.
3.Adjust the pump antenna.
4.Ensure smartphone permissions are given to the pump.
Poor WiFi signal to router| 1.The WiFi antenna can be relocated from the top
cover of the drive to a location with better WiFi signal. The antenna bulkhead
on the cover has a SMA Female connector, and the antenna has a SMA Male
connector.
A SMA extension cable can be used to move the antenna to a more favorable
location such as around the corner of a wall or outside of an enclosure.
2.Consider operating the pump in Direct Connect mode. Refer to the Direct
Connect, page 7 for instructions.
Alarms and Warnings
When an alarm is triggered the drive’s ON/STOP LED will blink RED and a fault
code will display. The pump will stop until the alarm is resolved.
When a Warning is triggered the drive’s ON/STOP LED will blink GREEN/YELLOW
and a fault coded will display.
Depending on your particular setup, fault codes will display on one or more of
the user interfaces:
- Pentair Home App
- Automation System Interface
- Optional Touchscreen Controller (Almond – P/N 356159z, Black – P/N 356348z)
ALARM / WARNING | DESCRIPTION | DEFINITION |
---|
Weak W-Fi
Connection| Weak Wifi connection detected.| Pump antenna may be obstructed or
too far away from your router. The antenna wire can be extended.
Refer to the !neeIliFlo3 VSF Installation and Maintenance Guide (P/N 356231)
for instructions.
Offline| The pump is offline.| The Pentair cloud cannot connect to your pump.
This could be caused by a power outage at the pump or router. or a loss of
WiFi signal to the pump.
Priming Failure| The pump has reported a Priming Failure Alarm.| Priming
failure can be caused by lack of water in the volute strainer basket.
Overheat| The pump has reported an Overheat Condition.| The pump motor has
detected an abnormally high internal temperature. This can be caused by a
blockage of the cooling fan inlet or outlet. or by excessively high ambient
air temperature.
The pump will attempt to protect itself by reducing the motor speed to give
the motor and drive a chance to cool down.
Over Current| The pump has reported an Over Current Condition,| Load has
increased on the motor: due to debris. part interference. temperature issues.
age of parts. or supplied voltage.
Inspect the rotating parts of the pump for blockages or debris buildup.
Refer to the pump IntelliF1o3 VSF Installation and Maintenance Guide (P/N
356231) for disassembly and reassembly instructions.
Over Voltage| The pump has reported an Over Voltage Alarm.| Supplied voltage
is outside of the proper range. When voltage returns to the normal the alert
will clear and the pump will resume operation.
Under Voltage| The pump has reported an Under Voltage Alarm.| Supplied voltage
is outside of the proper range. When voltage returns to the normal the alert
will clear and the pump will resume operation.
Speed Limit| The pump has reported a Speed Limit Warning.| The pump is
operating at the programmed maximum speed in order to achieve the desired
speediflow.
Refer to Limits Parameters on page 8 for instructions on adjusting the Speed
Limit.
If this alert displays and the Speed Limit is already set to 100%. then the
pump may not be capable of achieving the desired flow rate.
Pressure Limit| The pump has reported a Pressure Limit Waming.| The pump is
operating at the programmed maximum system pressure.
The pump monitors Total Dynamic Head. and not outlet pressure. so it may
differ from the reading on the filter gauge.
Refer to Limits Parameters on page 8 for instructions on adjusting the pump
Pressure Limit.
Flow Limit| The pump has reported a Flow Limit Warning.| The pump is operating
at the programmed maximum flow rate.
Refer to Limits Parameters on page 8 for instructions on adjusting the pump
Flow Limit,
Internal Fault| The pump has an internal error.| This alert can be caused by a
few different types of internal hardware or software errors in the drive.
Disconnect power to the pump and reconnect after one minute. If the alert
remains. contact a qualified pool professional.
Drive is Deratinc (Warning)| The pump is slowing down 😮 prevent the drive from
overheating.| This alert usually accompanies an Overheat or Over Current
alert.
It is intended to note that the pump will continue to operate at a reduced
speed as long as possible.
After the drive has cooled enough it will automatically resume normal
operation.
Derating Alarm – Exceeded & Cut Off| The pump has stopped to prevent the drive
from overheating.| The motor and drive are not able to reduce speed enough to
protect themselves. The motor will stop and Pentair Home will display this
alarm.
When the drive has cooled enough. it will automatically resume operation and
attempt to run the requested program.
Thermal Mode| The pump operating in Thermal Mode.| The pump is operating in
Thermal mode. Thermal Mode is controlled by the drive’s internal temperature.
not water temperature.
This is Intended to keep motor components from freezing, but should not be
solely relied on for full filtration system freeze protection.
1620 HAWKINS AVE., SANFORD, NC 27330 •
919-566-8000
10951 WEST LOS ANGELES AVE., MOORPARK, CA 93021 •
805-553-5000
WWW.PENTAIR.COM
All indicated Pentair trademarks and logos are property of Pentair. Third
party registered and unregistered trademarks and logos are the property of
their respective owners. Apple® and App Store® are registered trademarks of
Apple Inc. in the United States and/or other countries. iOS® is a registered
trademark of Cisco Technology, Inc. in the United States and/or other
countries. Google Play® and Android® are registered trademarks of Google LLC
in the United States and/or other countries. The Bluetooth® word mark and logo
are registered trademarks of Bluetooth SIG, Inc. in the United States and/ or
other countries. Other trademarks and trade names are those of their
respective owners. Because we are continuously improving our products and
services, Pentair reserves the right to change specifications without prior
notice.
© 2022 Pentair. All rights reserved. This document is subject to change
without notice.
Read User Manual Online (PDF format)