PENTAIR Hypro ProStop-E Single Nozzle Body User Manual
- June 9, 2024
- Pentair
Table of Contents
PENTAIR Hypro ProStop-E Single Nozzle Body
IMPORTANT SAFETY INSTRUCTIONS
SAVE THESE INSTRUCTIONS – This manual contains important instructions that
should be followed during installation, operation, and maintenance of the
product.
This is the safety alert symbol. When you see this symbol in this manual, look
for one of the following signal words and be alert to the potential for
personal injury!
indicates a hazard which, if not avoided, will result in death or serious
injury.
indicates a hazard which, if not avoided, can result in death or serious
injury.
indicates a hazard which, if not avoided, can or may result in minor or
moderate injury.
NOTE: Addresses practices not related to personal injury.
California Proposition 65 Warning
This product and related accessories contain chemicals known to the State of
California to cause cancer, birth defects or other reproductive harm.
INSTALLATION & OPERATION
GENERAL INFORMATION
Prostop-E valves provide precision control of on/off function of spraying with
high flow and low power consumption.
PERFORMANCE
- Operating Pressure…………..150 PSI (10 bar) max
- Flow……………………………….2.0 GPM with 5 PSI pressure drop through valve (7.57 LPM @ 0.34 bar)
- Wetted Components………….FKM, Nylon, Viton, Stainless Steel, Acetal, Teflon
POWER REQUIREMENTS
- Voltage………………………….9 to 16 VDC
- Steady State Amperage………………….50 mA
- Actuating…………………….. 1.9 A in-rush current (50 milliseconds), 550 mA for a total time of 250 ms
DIMENSIONAL DATA
Nozzle Body Clamp Torque: 17 inlbs.
Connector Information:
- M12 style
- IN: A-Code Keying
- OUT: D-Code Keying
Termination Cap 2300-0067 required for protection of any unused connector port
DIGITAL/LINBUS OPERATION
- The ProStop E Single is compatible with Pentair Cannode with firmware revision 1.05 and higher (PN CN32-0001) to allow this product to integrate into an ISOBUS system.
- Each Pentair Cannode supports up to 32 ProStop E Single nozzle bodies while maintaining individual nozzle control. Multiple Pentair Cannodes can be used in the same system to support any number of ProStop E nozzle bodies.
- For information on individual Cannode operation, reference L-1586 or contact Hypro Service Center.
ANALOG OPERATION
- When a 12VDC signal is sent to the Analog pin, the valve will open. When the signal is removed, the valve will close, similar to controlling a conventional section valve.
WIRING OPTIONS
- Cordsets are M12 Female style, straight connectors with a minimum IP 67 rating.
- Cordsets can be sourced directly from Pentair. Refer to part numbers in the Parts List Index of this manual.
- 2520-0265 = Daisy chain threaded cordset.
TROUBLESHOOTING
SYMPTOM: POSSIBLE CAUSE(S): CORRECTIVE ACTION
- Valve does not open.
- Power fault / low voltage
- Inspect for power supplied to the valve. Verify suitable voltage is present using a voltage meter.
- Overpressure
- Valve will not open at pressures above 150PSI (10 bar). Reduce system pressure.
- Debris obstructing ball movement
- Prevent contamination by practicing good sprayer hygiene and utilizing or installing line strainers in the boom plumbing. Flush plumbing with clean water to expel other debris before reattaching valve. Prevent subsequent contamination by utilizing or installing line strainers in the boom.
- Loss of communication with task controller
- Verify valve functionality by actuating each valve with Pentair-Hypro SprayIt app. If successful, review task controller setup, ensure CANbus wiring is in good condition and connections are fully seated.
- Slow leak through valve when closed.
- Debris on valve seat
- Prevent contamination by practicing good sprayer hygiene and utilizing or installing line strainers in the boom plumbing. Flush system with clean water to dislodge and expel debris. Remove nozzle body and flush plumbing with clean water. Reinstall nozzle body.
PART LIST
REF DESCRIPTION QTY PART
-
1A Five Way Turret 1 4203-0005N
1B Three Way Turret (Optional) 1 4203-0004N -
Turret Clip 1 4200-0005A
-
O-Ring 2 1721-0213
-
O-Ring 2 1721-0212
-
O-Ring 1 1721-0214
-
Turret Seal 1 4200-0006V
-
O-Ring 1 1721-0220
Parts # 1, 2, and 7 are sold individually.
Service Kit 3430-0754V includes:
REF DESCRIPTION QTY PART #
- O-Ring 2 1721-0213
- O-Ring 2 1721-0212
- O-Ring 1 1721-0214
- Turret Seal 1 4200-0006V
LIMITED WARRANTY ON HYPRO/SHURFLO AGRICULTURAL PUMPS & ACCESSORIES
The Hypro/Shurflo agricultural products brought to you by Pentair Flow
Technologies, LLC and its directly related affiliates
(collectively, “Hypro”) are warranted to be free of defects in material and
workmanship under normal use for the time periods listed below, with proof of
purchase.
- Pumps and Closed Transfer Systems: One (1) year from the date of purchase.
- Accessories: Ninety (90) days from the date of purchase.
This limited warranty will not apply to products that were improperly
installed, misused, misapplied, damaged, altered, or incompatible with fluids
or components not manufactured by Hypro. This limited warranty is the sole and
exclusive warranty provided by Hypro for the products. HYPRO DISCLAIMS ALL
OTHER WARRANTIES, WHETHER EXPRESS OR IMPLIED OR STATUTORY, INCLUDING BUT NOT
LIMITED TO, ANY IMPLIED WARRANTY OF MERCHANTIBILITY AND FITNESS FOR A
PARTICULIAR PURPOSE. HYPRO SHALL NOT BE LIABLE FOR ANY INDIRECT, INCIDENTAL,
SPECIAL, CONSEQUENTIAL OR EXEMPLARY DAMAGES, INCLUDING BUT NOT LIMITED TO,
DAMAGES FOR LOSS OF PROFITS, GOODWILL, USE, DATA OR OTHER INTANGIBLE LOSSES
(EVEN IF HYPRO HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES), WITH
RESPECT TO THIS LIMITED WARRANTY OR ANY OTHER MATTER RELATING TO THE PRODUCTS.
SOME JURISDICTIONS DO NOT ALLOW THE EXCLUSION OF CERTAIN WARRANTIES OR THE
LIMITATION OR LIMITATION OF LIABILITY FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES
IN CERTAIN CIRCUMSTANCES. ACCORDINGLY, SOME OF THE ABOVE LIMITATIONS MAY NOT
APPLY.
Hypro’s obligation under this limited warranty policy is limited to repair or
replacement of the product, as determined by Hypro in
its sole and absolute discretion. This limited warranty is in lieu of all
other warranties, expressed or implied, and no other person is authorized to
give any other warranty or assume obligation or liability on Hypro’s behalf.
Hypro shall not be liable for any labor, damage or other expense.
RETURN PROCEDURES
Buyer must give Hypro notice in writing of any alleged defected covered by
this warranty within thirty (30) days of the discovery of such defect during
the warranty period. Buyer should be prepared to give Hypro full details the
defect, including the model number, date of purchase, and from whom you
purchased your product. Hypro may request additional information, and may
require a sketch to illustrate the problem.
Contact the appropriate Hypro Service Department to receive a Return
Merchandise Authorization number (RMA#). Returns are to be shipped with the
RMA number clearly marked on the outside of the package. Hypro shall not be
liable for freight damage incurred during shipping. Please package all returns
carefully. All products returned for warranty work should be sent shipping
charges prepaid:
US/CANADA
Technical: 800-445-8360 Hypro
Warranty: 800-468-3428 Shurflo
Warranty: 800-854-3218
hypro.technical@pentair.com
rvreturns@pentair.com
marinereturns@pentair.com
EUROPE
+32 14 25 99 18
hypro-orders@pentair.com
UNITED KINGDOM
+44 1954 262333
hypro-orders@pentair.com
SOUTH AMERICA & CENTRAL AMERICA
vendas.pwdb@pentair.com
ALL OTHER REGIONS HYPRO / PENTAIR
Technical: 800-445-8360
Hypro Warranty: 800-468-3428
Shurflo Warranty: 800-854-3218
hypro.technical@pentair.com
rvreturns@pentair.com
marinereturns@pentair.com
All products must be flushed of any chemical (ref. OSHA section 1910.1200 (d)
(e) (f) (g) (h)) and hazardous chemicals must be labeled/ tagged before being
shipped to Hypro for service or warranty consideration. Hypro reserves the
right to request a Material Safety Data Sheet from the returnee for any
pump/product it deems necessary. Hypro reserves the right to “disposition as
scrap” products returned which contain unknown fluids. Hypro reserves the
right to charge the returnee for any and all costs incurred for chemical
testing, and proper disposal of components containing unknown fluids. Hypro
requests this in order to protect the environment and personnel from the
hazards of handling unknown fluids. All returns will be tested per Hypro’s
factory criteria. Where products are found not to be defective (under the
terms of this limited warranty), then the Buyer must pay return packing and
freight charges. Where products are tested and found to be covered by this
limited warranty, then Pentair will pay for return packing and freight
charges. Hypro reserves the right to choose the method of transportation.
Carriers, including U.S.P.S., airlines, UPS, ground freight, etc., require specific identification of any hazardous material being shipped. Failure to do so may result in a substantial fine and/or prison term. Check with your shipping company for specific instructions.
375 FIFTH AVENUE
NW NEW BRIGHTON, MN 55112 US PHONE:
651-766-6300,
800-424-9776 FAX:
800-323-6496
PENTAIR.COM
Pentair trademarks and logos are owned by Pentair or its affiliates. Third
party registered and unregistered trademarks and logos are the property of
their respective owners. Because we are continuously improving our products
and services, Pentair reserves the right to change specifications without
prior notice. Pentair is an equal opportunity employer.
L-3111 (04-15-21) ©2021 Pentair. All Rights Reserved.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>