PENTAIR SHEF40 Submersible/Effluent Pump Instruction Manual

June 9, 2024
Pentair

SHEF40 Submersible/Effluent Pump
Instruction Manual

SAFETY INFORMATION

Carefully read and follow all safety instructions in this manual or on pump.
This is the safety alert symbol. When you see this symbol on your pump or in this manual, look for one of the following signal words and be alert to the potential for personal injury!
DANGER warns about hazards that will cause serious personal injury, death or major property damage if ignored.
WARNING warns about hazards that can cause serious personal injury, death or major property damage if ignored.
CAUTION warns about hazards that will or can cause minor personal injury or property damage if ignored.
The word notice indicates special instructions which are important but not related to hazards.

  1. read these rules and instructions carefully. Failure to follow them could cause serious bodily injury and/or property damage.

  2. Check your local codes before installing. You must comply with their rules.

  3. Vent sewage or septic tank according to local codes.

  4. Do not install pump in any location classified as hazardous by National Electrical Code, ANSI/NFPA 80-1984 or the Canadian Electrical Code.
    WARNING Hazardous voltage. can shock, burn, or kill. During operation the pump is in water.
    To avoid fatal shocks, proceed as follows if pump needs servicing:
    Do not smoke or use devices that can generate sparks in a septic (gaseous) environment.

  5. 5A. Disconnect power to outlet box before unplugging pump.
    5B. Take extreme care when changing fuses. Do not stand in water or put your finger in the fuse socket.
    5C. Do not modify the cord and plug. When using the cord and plug, plug into a grounded outlet only. When wiring to a system control, connect the pump ground lead  to the system ground.

  6. Be sure that construction and access to septic sumps conform with all OSHA requirements.

  7. Do not run the pump dry. Dry running can overheat the pump, (causing burns to anyone handling it) and will void the warranty.

  8. The pump normally runs hot. To avoid burns when servicing pump, allow it to cool for 20 minutes after shutdown before handling it.

  9. The pump is permanently lubricated. No oiling or greasing is required in normal operation. for overhaul, see instructions under “Service”. 5743 1207

California proposition 65 Warning
WARNING This product and related accessories contain chemicals known to the State of California to cause cancer, birth defects or other reproductive harm.

DESCRIPTION

This submersible / effluent pump is designed for effluent and wastewater removal, sump drainage, dewatering and flood control. Units have built in thermal overload  protection with automatic reset. The mechanical seal and ball bearings on the motor shaft are permanently lubricated. Stainless steel hardware and a heavy duty lift out handle allow for easy disassembly after extended use.
notice: This unit is not designed for applications involving salt water or brine! Use with salt water or brine will void warranty.

SPECIFICATION

Power supply required …………. See “Motor, Switch and Cord Specifications” chart below
Motor duty ………………………………………………..Intermittent
Maximum Liquid Temperature …………………… 120°F (49°C)
Discharge Adapter ………………………………………1-1/2″ NPT

Motor & cord specifications

Model Number| Motor
HP| Voltage| Motor Full
Load Amps| Individual
Branch Circuit
Required (Amps)| Cord
Length
in ft. (m)| Switch Setting
in inches (mm)| Discharge
Adapter
Size
---|---|---|---|---|---|---|---
On| Off
SHEF40M1| 4/10| 115/1| 12.0| 15| 20 (6.1)| –| –| 1-1/2″
SHEF40A1| 4/10| 115/1| 12.0| 15| 20 (6.1)| 11.5 (292)| 3.5 (89)| 1-1/2′
SHEF40M2| 4/10| 230/1| 6.0| 15| 20 (6.1)| –| –| 1-1/2′
SHEF40A2| 4/10| 230/1| 6.0| 15| 20 (6.1)| 11.5 (292)| 3.5 (89)| 1-1/2′

PERFORMANCE

| | | | GPM AT TOTAL FEET| | | |
---|---|---|---|---|---|---|---|---
Model| I| 5′| I| 10′ I 15′ I 20′| I| 25′| I| 30′| No flow at height
shown below
| | | | CAPACITY GALLONS/MINUTE| | | |
SHEF40| I| 70| I| 60 I 45 I 35| I| 20| | 9| 33′

INSTALLATION

WARNING Hazardous voltage. Can shock, burn or kill. Do not lift pump by the power cord. See “Cord Lift Warning” below.
NOTICE: Install the pump on a hard, level surface (cement, asphalt, etc.). Never place the pump directly on earth, clay or gravel surfaces. Install the pump in a sump basin with a minimum diameter of 18″ (46cm).

Piping
Piping must not be smaller than pump discharge.
The pump is designed to operate partially or completely submerged in effluent liquids and pump semi-solid fluids up to 3/4″ (51mm) in diameter.
When installed in an effluent system, the pipe must be capable of handling semi-solids of at least 3/4″ (19mm) in diameter.
The rate of flow in the discharge pipe must keep any solids present in suspension in the fluid. To meet minimum flow requirements (2 feet per second in the discharge line), size the pipe as follows:

A pipe size of: Will Handle a flow rate of:
 1-1/2″ (38mm) 12 GPM
 2″ (51mm) 21 GPM
 2-1/2″(64mm) 30 GPM
 3″(76mm) 48 GPM

In an effluent system use a 1-1/2″ (38mm) check valve in pump discharge to prevent backflow of liquid into sump basin. The check valve should be a free flow valve that will easily pass solids. Be sure check valve installation complies with local codes.
Be sure that the wide-angle float switch hangs freely. It should not be able to come in contact with the sides or bottom of the sump pit.
Make sure the sump pit is free of any debris that could obstruct the intake volute or switch.
Use plumbing materials that are approved by local building codes when connecting pipes between pump and sewer outlet.
Notice: For critical indoor installations where additional high water protection is desired, install a “Q-Alert” audible alarm system in the sump pit. For outdoor installations,  confer with your Hydromantic distributor.
Connect the power cord to a 3-prong grounded AC receptacle.
WARNING Hazardous voltage. can shock, burn or kill. do not remove the grounding pin from the power cord.
Avoid using extension cords or 2-prong adapter plugs.
Insert the piggyback plug that comes from the wide-angle float switch directly into the power receptacle.
Insert the pump power cord directly into the back of the piggyback receptacle.
Test the pump installation by filling the sump basin with enough water to activate the pump and repeat this cycle until satisfied with pump operation.
Notice: For best performance of check valve when handling solids, do not install it with the discharge more than 45° above the horizontal. Do not install the check valve in a vertical position as solids may settle in the valve and prevent it from opening on startup.
Drill a 1/8″ (3mm) hole in the discharge pipe about 1–2″ (25-51 mm) above the pump discharge connection (but below check valve) to prevent relocking the pump.

Electrical
WARNING Hazardous voltage. can shock, burn, or kill. When installing, operating, or servicing this pump, follow the safety instructions listed below.

  1. do not splice the electrical power cord.
  2. do not allow the plug on the end of the electrical cord to be submerged.
  3. do not use extension cords. They are a fire hazard and can reduce voltage sufficiently to prevent pumping and/or damage motor.
  4. do not handle or service the pump while it is connected to the power supply.
  5. do not remove the grounding prong from the plug or modify the plug. To protect against electrical shock, the power cord is a three-wire conductor and includes a 3- prong grounded plug. Plug the pump into a 3-wire, grounded, grounding-type receptacle. Connect the pump according to the NEC or CEC and local codes.

WARNING

Risk of electrical shock.
Can burn or kill.
Do not lift pump by power cord.

CORD LIFT WARNING

  1. Attempting to lift or support pump by power cord can damage cord and cord connections.
  2. Cord may pull apart, exposing bare wires with possibility of fire or electrical shock.
  3. Lifting or supporting pump by power cord will void warranty.
  4. Use lifting ring or handle on top of pump for all lifting/lowering of pump. Disconnect power to pump before doing any work on pump or attempting to remove pump  from sump.

For automatic operation (SHEF40A1 and A2), plug or wire the pump into an automatic float switch or duplex controller.
The pump will run continuously when plugged directly into anelectrical outlet (SHEF40M1 and M2).
Connect or wire pump to its own individual branch circuit with no other outlets or equipment in the circuit. Size fuses or circuit breakers according to the “Motor, Switch and Cord Specifications” chart.

WARNING: Risk of electrical shock and fire. can burn, kill or cause property damage. Be sure that power supply information (Voltage/ Hertz/Phase) on pump motor nameplate matches incoming power supply exactly. Install pump according to all electrical codes that apply.

Operation

WARNING: Risk of fire or explosion. can cause severe personal injury, property damage or death. Do not use in explosive atmospheres. Pump water only with this  pump.
NOTICE: Do not allow the pump to run in a dry sump. It will void the warranty and may damage the pump.
An automatic overload protector in the motor will protect the motor from burning out due to overheating/overloading.
When the motor cools down, the overload protector will automatically reset and start the motor.
If the overload trips frequently, check for the cause. It could be a stuck impeller, wrong/low voltage, or an electrical failure in the motor. If an electrical failure in the motor is  suspected, have it serviced by a competent repairman.
The pump is permanently lubricated. No oiling or greasing is required.
Cycle the pump at least once every month to be sure that the system is working satisfactorily.
NOTE: any of the following will void the pump warranty:

  1. Submerging, plugging, damaging or taping shut a vented cord.
  2. Pumping materials other than those the pump was designed to pump or continuously pumping water hotter than 120°F (49°C).
  3. Cutting or splicing a power cord or switch cord.
  4. Anyone other than an authorized Hydromantic service technician dismantling the pump.
  5. Removing the cord tag from the cord.

SERVICE

General
WARNING: Hazardous voltage and risk of cord damage. can shock, burn, or kill. Before removing the pump from the basin for service, always disconnect electrical power  to the pump and the control switch. Do not lift the pump by the power cord. See the “Cord Lift Warning”, Page 2. disinfect the pump
Place the pump in an area where it can be cleaned thoroughly. Remove all scale and deposits on the pump.
Submerge the complete pump in a disinfectant solution (Clorox or chlorine bleach) for at least one hour before disassembling the pump.
The pump motor housing contains a special lubricating oil which should be kept clean and free of water at all times.
NOTICE: Whenever the motor housing is being removed for service, remove oil and replace it with new oil at reassembly.
Use only oil listed in parts list in this manual. When filling with new oil, do not overfill. Be sure that the oil level is 1/4″ above the motor windings.

Pump disassembly

Impeller and seal replacement
(See “Disinfect the Pump”)
A. Impeller removal (See the pump disassembly drawing):

  1. Remove the oil fill plug and turn the pump upside down to drain oil.
    a. Remove the three capscrews that secure the support legs.
    b. Remove the seven capscrews that secure the suction plate.
    c. Remove any obstructions that prevent free movement of the impeller.
    d. Clear the small vent hole that is drilled into the impeller cavity.

  2. Remove the capscrews holding the upper motor housing to the lower motor housing.
    Notice: The motor lead wires are permanently attached to the power cord. Be sure they do not pull loose when you remove the upper motor housing. The power cord is not removable or replaceable.
    PENTAIR SHEF40 Submersible Effluent Pump - Figure 2

  3. Remove the capscrews holding the lower motor housing to the volute; lift off the lower motor housing.

  4. Hold the rotor shaft assembly and unscrew the impeller by turning it counter-clockwise.
    a. Remove impeller and clean it.
    b. If no more service is needed, reverse instructions above to reassemble the pump.
    c. Fill the pump with clean dielectric oil (Part No. U1978A).
    d. Be sure that the oil level is 1/4” above the motor windings.
    e. Replace fill plug.

check Motor Windings

  1. Use a quality volt-ohm-meter (VOM) when performing these inspections.
  2. Set the meter to Rx1.
  3. Touch both flat prongs of the power cord to the leads of the VOM and observe the readings:
    a. 230 Volt System – 0.8 to 1.1 ohms
    b. 115 Volt System – 1.6 to 1.8 ohms

EXPOLAR VIEW
PENTAIR SHEF40 Submersible Effluent Pump - Figure 3

Limited Warranty

Hazardous voltage. Can shock, burn or kill. Do not lift pump by the power cord. See “Cord Lift Warning” below.
NOTICE: Install the pump on a hard, level surface (cement, asphalt, etc.). Never place the pump directly on earth, clay or gravel surfaces. Install the pump in a sump basin  with a minimum diameter of 18″ (46cm).

Piping
Piping must not be smaller than pump discharge.
The pump is designed to operate partially or completely submerged in effluent liquids and pump semi-solid fluids up to 3/4″ (51mm) in diameter.
When installed in an effluent system, the pipe must be capable of handling semi-solids of at least 3/4″ (19mm) in diameter.
The rate of flow in the discharge pipe must keep any solids present in suspension in the fluid. To meet minimum flow requirements (2 feet per second in the discharge line), size the pipe as follows:

HYdroMatic
293 Wright street, delavan, Wi 53115
Phone: 888-957-8677
Fax: 800-426-9446
Web Site: hydromatic.com

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Pentair User Manuals

Related Manuals