LITHONIA LIGHTING BGR ALO SWW2 MVOLT PER Dusk to Dawn LED Area Light Instruction Manual
- June 9, 2024
- LITHONIA LIGHTING
Table of Contents
LITHONIA LIGHTING BGR ALO SWW2 MVOLT PER Dusk to Dawn LED Area Light
Protect yourself.
Before installing, read the entire instructions carefully and save them for
future reference. Date installed: _____ Failure to follow any of
these instructions could void product warranties. For a complete list of
product Terms and Conditions, visit
www.acuitybrands.com. Acuity Brands Lighting,
Inc. assumes no responsibilities for claims arising
out of improper or careless installation or handling of its products. Upon
receipt of fi xture, thoroughly inspect for any freight damage. All damage
should be reported to the delivery carrier. Compare the catalog description
listed on the packing slip with the fi xture label on the inside of the
housing to be sure you have received the correct merchandise.
IMPORTANT SAFETY INSTRUCTIONS
READ AND FOLLOW THESE SAFETY INSTRUCTIONS!
- To reduce the risk of death, personal injury or property damage from fi re, electric shock, falling parts, cuts/abrasions, and other hazards please read all warnings and instructions included with and on the fi xture box and all fi xture labels.
- Before installing, servicing, or performing routine maintenance upon this equipment, follow these general precautions.
- Commercial installation, service and maintenance of luminaires should be performed by a qualifi ed licensed electrician.
- For Residential installation: If you are unsure about the installation or maintenance of the luminaires, consult a qualifi ed licensed electrician and check your local electrical code.
- Maintenance of the luminaires should be performed by a person(s) familiar with the luminaires’ construction and operation and any hazards involved. Regular fi xture maintenance programs are recommended.
- This fi xture is intended to be connected to a properly installed and grounded UL listed junction box.
- It will occasionally be necessary to clean the outside of the refractor/lens. The refractor/lens should be washed in a solution of warm water and any mild, non-abrasive household detergent, rinsed with clean water, and wiped dry. Should the optical assembly become dirty on the inside, wipe the refractor/lens and clean in the above manner, replacing damaged gaskets as necessary.
- DO NOT INSTALL DAMAGED PRODUCTS! This luminaire has been properly packed so that no parts should have been damaged during transit. Inspect to confi rm. Any part damaged or broken during or after assembly should be replaced.
- Recycle: For information on how to recycle LED electronic products, please visit www.epa.gov.
- These instructions do not purport to cover all details or variations in equipment nor to provide every possible contingency to meet in connection with installation, operation, or maintenance. Should further information be desired or should particular problems arise which are not covered sufficiently for the purchaser’s or owner’s purposes, this matter should be referred to Acuity Brands Lighting, Inc.
CAUTION RISK OF FIRE
- Keep combustible and other materials that can burn, away from the lamp/lens.
- Do not operate in close proximity to persons, combustible materials or substances affected by heat.
CAUTION RISK OF PRODUCT DAMAGE
- Never connect components under load.
- Do not mount or support these fi xtures in a manner that can cut the outer jacket or damage wire insulation.
- Unless individual product specifi cations deem otherwise: Never connect an LED product directly to a dimmer packs, occupancy sensor, timing device, or other related control devices. LED fi xtures must be powered directly off a switched circuit.
- Unless individual product specifi cations deem otherwise: Do not restrict fi xture ventilation. Allow for some volume of airspace around the fi xture. Avoid covering LED fi xtures with insulation, foam, or other material that will prevent convection or cooling.
- Unless individual product specifi cations deem otherwise: Do not exceed fi xtures maximum ambient temperature.
- Only use fi xture in its intended location.
- LED products are Polarity Sensitive. Ensure proper Polarity before installation.
- Electrostatic Discharge (ESD): ESD can damage LED fi xtures. Personal grounding equipment must be worn during all installation or servicing of unit.
- Do not touch individual electrical components as this can cause ESD, shorten lamp life, or alter performance.
- Some components inside the fi xture may not be serviceable. In the unlikely event your unit may require service, stop using the unit immediately and contact an ABL representative for assistance.
- Changes or modifi cations not expressly approved by Acuity Brands Lighting could void the authority to operate the equipment.
- Always read the fi xtures complete installation instructions prior to installation for any additional fi xture specifi c warnings.
This equipment has been tested and found to comply with the limits for a class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when used in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit diff erent from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
5- YEAR LIMITED WARRANTY
Register your warranty on www.lightahome.com/warranty. Your prompt product registration confi rms your right to the protection available under the terms and conditions of your Lithonia Lighting warranty. Failure to follow any of these instructions could void product warranties. For a complete listing of product Terms and Conditions, please visit www.acuitybrands.com. Acuity Brands Lighting, Inc. assumes no responsibilities for claims arising out of improper or careless installation or handling of its products.
INSTALLATION INSTRUCTIONS
Mounting Hardware Included Waterproof Supply Fittings, Conduit & Silicone Sealant Required – Purchase Separately
REQUIRED TOOLS:
Remove fi xture components and parts pack. Check to ensure all parts are included. Note: Account for small parts and destroy packing material, as these may be hazardous to children.
Turn OFF the Power at the circuit breaker box!
CAUTION: Do not rely on wall switch alone to turn off the power.
PHOTOCONTROL INSTALLATION
Align the arrow on top of the Photocontrol with the arrow on the receptacle. Insert pins and twist clockwise until it locks in place.
Note: Keep photocontrol or Shorting Cap installed to ensure that no water will enter the photocontrol receptacle.
SURFACE MOUNTING See Fig. A
Note: Hardware included for mounting to wood surfaces only! Ensure that fi
xture is mounted onto a structurally sound surface that will support the fi
xture.
Note: Use mounting Hardware appropriate for your application!
- For Surface mounting, remove conduit plug (C) and pull supply wires through conduit hole.
- Mark mounting hole locations using the template on the box and drill 3/16” diameter pilot holes in wooden mounting surface.
- Install two 2” Lag bolts (D) in bottom predrilled holes, leaving about 3/8” space under the head.
- Install the third 2” Lag bolt (D) into the predrilled hole on top and back the Screw out. This will leave the hole threaded and make installation easier.
- Place Fixture Housing on the two bottom bolts, install third lag bolt and tighten bolts to secure fi xture6.
- Make wire connections, push connections into arm and install conduit.
ARM MOUNTING See Fig. B.
Optional Mounting Arm (OMA) available (sold separately). Follow Mounting arm
instructions for mounting arm to surface. Ensure that arm is mounted onto
structurally sound surface that will support the fi xture.
Note: Use mounting Hardware appropriet for your application!
- Make wire connections and push mounting arm into the fi xture arm hole making sure not to pinch any wires.
- Tighten Set screws (E) with included Allen wrench (H) to secure fi xture to arm.
CAUTION: WIRING AND FIXTURE OPERATION
Make sure power is turned off !
Note: This fi xture is intended for use with conduit connectors, conduit and a properly installed and grounded UL wet location listed junction box.
Ground fixture
Use Wire Nut (F) to connect the (copper) house supply ground wire & the
(green) fi xture ground wire.
Note: If house wiring does not include a ground wire, consult your local
electrical code for approved grounding methods.
For proper connection, place the wire nut over the wires and twist clockwise until tight.
Connect supply wires
Use Wire Nuts (F) to connect the black fi xture wire to the black power supply wire and the white fi xture wire to the white (neutral) supply wire.
Turn on electricity
at the fuse or circuit breaker box and verify the success of the installation. Note: Test fi xture at night or block Photocontrol.
Apply silicone caulking
(not included) for moisture seal.
BRIGHTNESS LEVEL SETTING See Fig.C
Preset to full brighness (9000LM) indicated by the larger sun icon. If lower brightness is desired set dial to small sun icon.
LIGHT COLOR SETTING See Fig. C
Preset to COOL/4000K. Set dial to desired light color.
If desired, INSTALL DIFFUSER
Align the keyholes along the diff user rim with the 3 screw heads around the edge of the fi xture bottom, push up and rotate counter clockwise to install. Tighten screws to secure.See Fig. D.
Trouble Shooting Guide
If this fi xture fails to operate properly, use the guide below to diagnose and correct the problem.
- Verify that power is turned on at switch and breaker
- Verify that fixture is wired properly
- Verify that line voltage is correct.
- Test if Photocontrol works properly
The photocontrol in this fi xture is designed to turn on fi xture light at low
light levels.
If light does not come on or stays on:
Test if Photocontrol works properly:
- Cover Photocontrol – Light should come on.
- Shine a fl ashlight into Photocontrol – Light should go off .
If fi xture cylcles on and off :
- Light refl ecting back off any surrounding surfaces enters the photocontol. To correct problem, reposition the fi xture or eliminate refl ective surface.
If further technical assistance is required, contact:
Technical Support at: (800) 705-SERV
This LED light provides low maintenance service with no bulbs to change. Clean
surfaces with mild soap and water. Do not use abrasive materials such as
scouring pads or powders, steel wool or abrasive paper.
WARNING: There are no user serviceable parts inside fi xture.
Contractor Resources
Check out helpful programs, tools, installation videos and more!
References
- Acuity Brands | Lighting, Controls, and Building Management Solutions
- Acuity Brands | Lighting, Controls, and Building Management Solutions
- U.S. Environmental Protection Agency | US EPA
- Page Not Found
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>